Table III-1
Acceptable Computation Methodologies for Stormwater Management
Plans
| |||
---|---|---|---|
Method
|
Method Developed By
|
Applicability
| |
TR-20 (or commercial computer package based on TR-20)
|
USDA NRCS
|
Applicable where use of full hydrology computer model is desirable
or necessary
| |
Win TR-55 (or commercial computer package based on TR-55)
|
USDA NRCS
|
Applicable for land development plans within limitations described
in TR-55
| |
HEC-1/HEC-HMS
|
US Army Corps of Engineers
|
Applicable where use of full hydrologic computer model is desirable
or necessary
| |
Rational Method (or commercial computer package based on Rational
Method)
|
Emil Kuichling (1889)
|
For development sites less than 200 acres, Tc<60 minutes
or as approved by the Township
| |
EFH2
|
USDA NRCS
|
Applicable in rural and undeveloped areas subject to the program
limits
| |
Other methods
|
Varies
|
Other methodologies approved by the Township
|
Table 1
Minimum Buffer Widths by Stream Order
| |
---|---|
Stream Order
|
Buffer Width
(feet)
|
1 to 2
|
35
|
3 to 4
|
50
|
Over 4
|
75
|
Aboveground storage facility design criteria
| ||||||
---|---|---|---|---|---|---|
Facility Depth
| ||||||
Less than 2 feet
|
2 feet to 8 feet
|
Greater than 8 feet
| ||||
(a)
|
Embankment Geometry
| |||||
[1]
|
Top width (minimum)
|
2 feet
|
5 feet
|
8 feet
| ||
[2]
|
Interior side slope (maximum)
|
2:1
|
3:1
|
5:1
| ||
[3]
|
Exterior side slope (maximum)
|
2:1
|
3:1
|
3:1
| ||
(b)
|
Embankment construction
| |||||
[1]
|
Key trench
|
Not required
|
Required
|
Required
| ||
[2]
|
Pipe collar
|
Not required
|
Required
|
Required
| ||
[3]
|
Compaction density
|
Not required
|
Required
|
Required
| ||
(c)
|
Internal Construction
| |||||
[1]
|
Dewatering feature
|
N/A
|
Required
|
Required
| ||
[2]
|
Pretreatment elements
|
Not required*
|
Required
|
Required
| ||
(d)
|
Outlet Structure
| |||||
[1]
|
Pipe size (minimum)
|
6 inches
|
12 inches
|
15 inches
| ||
[2]
|
Pipe material
|
SLHDPE, PVC, RCP
|
SLHDPE, RCP
|
RCP
| ||
[3]
|
Anticlogging devices
|
Required
|
Required
|
Required
| ||
[4]
|
Antivortex design
|
Not required
|
Required
|
Required
| ||
[5]
|
Watertight joints in piping?
|
No
|
Yes
|
Yes
| ||
(e)
|
Spillway Requirements
| |||||
[1]
|
Spillway freeboard (minimum)
|
Not required
|
3 inches
|
6 inches
| ||
[2]
|
Width (minimum)
|
Not required
|
10 feet
|
20 feet
| ||
[3]
|
Width (maximum)
|
Not required
|
50 feet
|
50 feet
| ||
[4]
|
Spillway channel design
|
Not required
|
Required
|
Required
| ||
[5]
|
Routing of one-hundred-year storm
|
Permitted
|
Permitted
|
Permitted
|
*Pretreatment required for infiltration BMPs unless shown to
be unnecessary.
| ||
---|---|---|
N/A = Not applicable
| ||
SLHDPE = Smooth lined high density polyethylene pipe; PVC =
Polyvinyl chloride;
| ||
RCP = Reinforced concrete pipe
|
Subsurface storage facility design criteria
| |||||
---|---|---|---|---|---|
Facility Type
| |||||
Infiltration and Storage
|
Storage without Infiltration
| ||||
(a)
|
Facility Geometry
| ||||
[1]
|
Depth from surface (maximum)
|
2 feet less than limiting zone
|
N/A
| ||
[2]
|
Loading ratio (maximum)
|
Per BMP Manual*
|
N/A
| ||
(b)
|
Distribution System Requirements
| ||||
[1]
|
Pipe size (minimum)
|
4 inches
|
4 inches
| ||
[2]
|
Pretreatment
|
Required
|
Required
| ||
[3]
|
Loading/balancing
|
Required
|
Not required
| ||
[4]
|
Observation/access ports
|
Required
|
Required
|
*Unless otherwise determined by professional geologic evaluation.
|
Conveyance facility design criteria
| ||||||
---|---|---|---|---|---|---|
Location
|
Within Public Street Right-of-Way
|
Outside Public Street Right-of-Way
| ||||
Loading
|
All
|
Vehicular Loading
|
Non-Vehicular Loading
| |||
(a)
|
Pipe design
| |||||
[1]
|
Material
|
SLHDPE, RCP
|
PVC, SLHDPE, RCP
|
PVC SLHDPE, RCP
| ||
[2]
|
Slope (minimum)
|
0.5%
|
0.5%
|
0.5%
| ||
[3]
|
Cover
|
1 foot to stone subgrade
|
1 foot to stone subgrade
|
1 foot to surface
| ||
[4]
|
Diameter (minimum)
|
15 inches
|
15 inches
|
8 inches
| ||
[5]
|
Street crossing angle
|
75° to 90°
|
N/A
|
N/A
| ||
[6]
|
Access/ maintenance port frequency (maximum)
|
400 feet
|
400 feet
|
600 feet
| ||
(b)
|
Inlet design
| |||||
[1]
|
Material
|
Concrete
|
Concrete
|
N/A
| ||
[2]
|
Grate depression
|
2 inches
|
2 inches
|
1 inch minimum
| ||
(c)
|
Manhole design
| |||||
[1]
|
Material
|
Concrete
|
Concrete
|
Concrete
| ||
(d)
|
Swale design
| |||||
[1]
|
Freeboard (minimum)
|
6 inches
|
N/A
|
6 inches
| ||
[2]
|
Velocity (maximum)
|
Stability check
|
N/A
|
Stability check
| ||
[3]
|
Slope (minimum)
|
1%
|
N/A
|
1%
| ||
[4]
|
Side slopes (residential area)
|
4:1 max
|
N/A
|
4:1 max
| ||
[5]
|
Side slopes (nonresidential area)
|
4:1 max
|
N/A
|
3:1 max
| ||
[6]
|
Bottom width to flow depth ratio
|
12:1
|
N/A
|
12:1
| ||
(e)
|
Outlet design
| |||||
[1]
|
End treatment
|
Headwall/ endwall
|
N/A
|
Headwall/ endwall or flared end section
| ||
[2]
|
Energy dissipater
|
Required
|
N/A
|
Required
|
N/A = Not applicable or no criteria specified
| |
---|---|
SLHDPE = Smooth lined high density polyethylene pipe; PVC =
Polyvinyl chloride;
| |
RCP = Reinforced concrete pipe
|