(a)
Except for single-family and two-family residences and accessory structures thereto, no building shall be constructed in such a manner that any part of the structure is more than 150 feet from a public street or highway, unless a fire lane is provided as hereinafter set forth. Such fire lane shall be provided by the owner thereof, who shall designate, construct and maintain the fire lane with a hard surface having a minimum width of 20 feet and a minimum height clearance of 14 feet terminating within 150 feet of the most distant point of such structure.
(b)
Every fire lane more than 150 feet in length shall either connect at each end to a dedicated street or be provided with a turnaround having a minimum diameter of 50 feet.
(c)
All fire lanes shall be maintained and kept in a state of good repair and plainly visible at all times by the owner, manager or person in charge of the premises, and the city shall never be responsible for the maintenance thereof.
(d)
No fire lane required by this section or any previous ordinance of the city shall be abandoned, altered or closed without written permission of the fire chief or his authorized representative of the city.
(1976 Code, sec. 14-65; 1998 Code, sec. 54-42; 2013 Code, sec. 22-93)