[Amended 9-9-1996 STM, Art. 4]
A. ANNUNCIATOR AUTHORITY HAVING JURISDICTION AUTOMATIC SPRINKLER AUTOMATIC SPRINKLER SYSTEM FIRE ALARM CONTROL PANEL (FACP) HYDROSTATIC TEST MASSACHUSETTS GENERAL LAW, CHAPTER 148, SECTION 26G (MGL C. 148, § 26G) MASSACHUSETTS GENERAL LAW CHAPTER 148, SECTION 26H (MGL C. 148, § 26H) NFPA NFPA 12 NFPA 12A NFPA 12B NFPA 13 NFPA 13A NFPA 13D NFPA 13R NFPA 14 NFPA 24 NFPA 25 NFPA 231 NFPA 231C
For the purpose of this chapter, the following terms, phrases, words and their derivations shall have the meanings given herein. The word "shall" is always mandatory and not discretionary.
A unit containing two or more identified targets or indicator lamps in which each target or lamp indicates the circuit condition or location to be annunciated.
The Chief of the Northborough Fire Department.
A device which automatically distributes water upon a fire in sufficient quantity either to extinguish it entirely or to prevent its spread.
An integrated system of underground and overhead piping designed in accordance with fire protection engineering standards. This installation includes one or more automatic water supplies. The portion of the sprinkler system above ground is a network of specially sized or hydraulically calculated piping installed in a building, structure or area, generally overhead, and to which sprinklers are attached in a systematic pattern. Each sprinkler system riser includes a control valve and a device for actuating an alarm when the system is in operation. The system is usually activated by heat from a fire and discharges water over a fire area.
A UL-listed, FM-approved control unit which will receive signals from remote detection and signaling devices, sound an audible and visual evacuation alarm and signal the Fire Department through a direct connection. This unit also contains the necessary equipment for transmitting alarms to the Fire Department.
A test of sprinkler piping which subjects all piping and devices to a static pressure of at least 200 pounds per square inch for a period of not less than two hours. In the event that the static pressure is in excess of 150 pounds per square inch, the test pressure shall be a pressure of at least 50 pounds per square inch greater than the static pressure.
A local option law adopted by the Town of Northborough requiring sprinklers to be installed in all new nonresidential construction with over 7,500 square feet of new floor area.
A local option law adopted by the Town of Northborough requiring sprinklers to be installed in new boarding and rooming houses.
The National Fire Protection Association.
The current edition of Carbon Dioxide Extinguishing Systems.
The current edition of Halon 1301 Fire Extinguishing Systems.
The current edition of Halon 1211 Fire Extinguishing Systems.
The current edition of The Installation of Sprinkler Systems.
The current edition of Inspection, Testing and Maintenance of Sprinkler Systems.
The current edition of Sprinkler Systems in One- and Two-Family Dwellings and Mobile Homes.
The current edition of Sprinkler Systems in Residential Occupancies Up to Four Stories in Height.
The current edition of Standpipe Systems.
The current edition of Installation of Underground Water Mains.
The current edition of Water Based Fire Protection Systems.
The current edition of General Storage.
The current edition of Rack Storage of Materials.