Section 101.1 is hereby amended to read as follows:
101.1 Title. These regulations shall be known as
the Building Code of the City of Garden Grove, hereinafter referred
to as "this Code."
(2940 § 3, 2022)
Section 113 (including subsections) is hereby amended and restated
to read as follows:
113 Board of Appeals. The Administrative Board of Appeals for the City shall hear and decide appeals of orders, decisions or determinations made by the Building Official relative to the application and interpretations of the Building Codes and Regulations of the City of Garden Grove including, without limitation, this Code. Refer to Title
2, Chapter
2.54, of this Code.
(2940 § 3, 2022)
Item # 2 under Building is hereby amended to read as follows:
2.
Masonry and/or concrete fences not over three feet high and
other fences not over seven feet high.
(2940 § 3, 2022)
Section [F]903.2 is hereby amended by adding the following after
the first paragraph:
Notwithstanding any other provisions in this Code, approved
automatic sprinkler systems shall be installed and maintained in accordance
with the latest edition of NFPA Standard 13 throughout all new buildings
or structures, regardless of fire walls, with a gross floor area of
6,000 square feet or more, or with a total height of 55 feet or more
above grade, or containing three or more stories.
Buildings or structures which presently exceed 6,000 square
feet of floor area constructed prior to the adoption of this Code,
upon or to which any alteration or additions are to be made which
would add more than 2,000 square feet to the existing square footage
of this building, shall have automatic sprinklers installed, as required
herein and above.
Buildings or structures which presently do not exceed 6,000
square feet of floor area, to which any alterations or additions are
made, and after such alterations or additions the floor area will
exceed 8,000 square feet, shall have automatic sprinkler systems installed,
as required herein and above. (Balance of Section to remain unchanged.)
(2940 § 3, 2022)
Table 1505.1 is hereby amended by the deletion of Table 1505.1
and the addition of a new Table 1505.1 thereto to read as follows:
TABLE 1505.1a
|
---|
MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
|
---|
IA
|
IB
|
IIA
|
IIB
|
IIIA
|
IIIB
|
IV
|
VA
|
VB
|
B
|
B
|
B
|
B
|
B
|
B
|
B
|
B
|
B
|
For SI: 1 foot = 304.8mm, 1 square foot = 0.0929m2
|
a.
|
Unless otherwise required in accordance with Chapter 7A.
|
(2940 § 3, 2022)
Section 1505.1.2 is hereby amended by the deletion of the entire
section and the addition of a new section thereto, to read as follows:
1505.1.2 Roof coverings within all other areas. The entire roof covering of every existing structure where more
than 50 percent of the total area is replaced within any one-year
period, the entire roof covering of every new structure, and any roof
covering applied in the alteration, repair or replacement of the roof
of every existing structure, shall be a fire-retardant roof covering
that is at least Class B.
(2940 § 3, 2022)