New land uses and structures, and alterations to existing land uses and structures, shall be designed, constructed, and maintained in compliance with the requirements of Table 17.28-1, in addition to the applicable development standards in Divisions 3 and 4 of Title 17.
Table 17.28-1 |
|---|
Development Standard | Requirement for H District | Additional Regulations |
|---|
Density | 8 units per gross acre maximum | See Chapter 17.160 for density bonuses for affordable housing. |
Lot Size | Single-family dwellings: 5,000 sq. ft. minimum; 8,000 sq. ft. maximum Duplexes: 5,000 sq. ft. minimum; 8,000 sq. ft. maximum Multifamily: 6,000 sq. ft. minimum; 8,000 sq. ft. maximum | |
Maximum Floor Area Ratio (FAR) | Single-family dwellings: Lots < 4,000 sq. ft.: Floor area up to 1,000 sq. ft. is permitted. Lots 4,000-10,000 sq. ft.: 0.25 Lots > 10,000 sq. ft.: Max. floor area of 2,500 sq. ft. is permitted. Duplexes: 0.40, up to a maximum of 3,200 sq. ft. Multifamily: 0.40, up to a maximum of 4,000 sq. ft. | See Section 17.100.040 for FAR bonus for affordable housing. |
Minimum Setbacks | See Section 17.108 for allowable encroachments into setbacks. See Section 17.112 for setbacks for auxiliary structures. |
Front | Primary buildings: 10 feet for buildings up to 15 feet high; 15 feet for buildings 15-18 feet high; 20 feet for building over 18 feet high. Setback may be reduced to the average front setbacks of existing single-family structures on the same side of the block1 but shall not be less than 10 feet.2 Garages: 18 feet |
Side | 5 feet for first story and total of 13 feet for both sides. For lots <50 feet wide, 5 feet each for a total of 10 feet both sides. 8 feet for second story and total of 22 feet for both sides. For lots <50 feet wide, 5 feet each for a total of 16 feet both sides. |
Side (street fronting) | 10 feet for first story. 16 feet for second story. |
Rear | 15 feet for first story. 20 feet for second story. |
Height Limit | Single-family dwellings: Two stories maximum, however no more than 50% of parcels containing single-family dwelling units in any block1 are permitted to exceed one story in height. Duplexes and Multifamily: Two stories maximum. One-story buildings: max. 15 feet to plate and 20 feet to peak. Two-story buildings: max. 20 feet to plate and 28 feet to peak. | See Chapter 17.208 for exceptions to two-story limit per block. See Chapter 17.112 for height limits for auxiliary structures. |
Minimum Open Space | Single-family dwellings: n/a Duplexes and Multifamily: 200 sq. ft. min. private open space directly accessible to unit. Second story units may locate half of private open space at grade level. | |
Parking | As required by Chapter 17.116 Off-Street Parking and Loading. | |
Footnotes: |
|---|
1 | Block shall mean both sides of the street lying between intersecting streets. Corner houses shall be counted on both street elevations. In situations where a block face is divided by an intersecting street compared with the opposite block face, the determination of block shall include all parcels to the nearest through street on either side of the intersecting street. |
2 | The setback shall be measured from the street facing wall of a primary residential building perpendicular to the right-of-way boundary; no existing building shall be considered to have a setback of less than zero. Should the property line be located within the right-of-way, the right-of-way feature closest to the parcel shall be used for purposes of measurement (e.g., back of sidewalk or edge of pavement). |
(Ord. 21-501 § 9)