That certain document entitled "California Building Code, 2022 Edition," which adopts by reference the International Building Code, 2021 Edition, as published by the California Building Standards Commission and the International Code Council including "Seismic Hazard Maps," as published by the United States Geological Survey (excluding Chapter 1 Division II, and Chapters 7A, 16A, 17A, 18A, 19A, 21A, 22A), including Chapter 1, Division I, and Appendix J are hereby adopted with the local amendments and provisions of this Chapter, and with Chapters 8.18 and 8.48 through 8.80 of the Santa Monica Municipal Code, as the Building Code of the City of Santa Monica.
(Added by Ord. No. 1945CCS § 3, adopted 6/8/99; amended by Ord. No. 2054CCS § 3, adopted 10/8/02; Ord. No. 2244CCS § 3, adopted 11/27/07; Ord. No. 2328CCS § 5, adopted 11/9/10; Ord. No. 2445CCS § 11, adopted 11/12/13; Ord. No. 2527CCS § 3, adopted 11/22/16; Ord. No. 2623CCS § 4, adopted 10/22/19; Ord. No. 2727CCS § 4, adopted 10/25/22)
Notwithstanding any provisions of the California Building Code, California Building Standards Code, State Housing Law or other codes adopted by any Chapter in Article VIII of the Municipal Code to the contrary, the following local amendments shall apply.
(Added by Ord. No. 1945CCS § 3, adopted 6/8/99; amended by Ord. No. 2054CCS § 3, adopted 10/8/02; Ord. No. 2244CCS § 3, adopted 11/27/07; Ord. No. 2328CCS § 5, adopted 11/9/10; Ord. No. 2445CCS § 11, adopted 11/12/13; Ord. No. 2527CCS § 3, adopted 11/22/16; Ord. No. 2623CCS § 4, adopted 10/22/19; Ord. No. 2727CCS § 4, adopted 10/25/22)
The following facilities are designated as essential facilities, which are necessary for emergency operations subsequent to a natural or man-made disaster: police stations, fire stations and City Hall. Such facilities shall be categorized as Risk Category IV as defined in Chapter 16 of the California Building Code.
(Added by Ord. No. 1945CCS § 3, adopted 6/8/99; amended by Ord. No. 2054CCS § 3, adopted 10/8/02; Ord. No. 2244CCS § 3, adopted 11/27/07; Ord. No. 2328CCS § 7, adopted 11/9/10; Ord. No. 2445CCS § 11, adopted 11/12/13; Ord. No. 2527CCS § 3, adopted 11/22/16; Ord. No. 2623CCS § 4, adopted 10/22/19; Ord. No. 2727CCS § 4, adopted 10/25/22)
In addition to those areas recognized under the State Seismic Hazards Mapping Act, certain portions of the City are hereby established as Seismic Hazard Zones and Geologic Hazard Zones. Said zones shall be known as outlined, illustrated and designated in the Safety Element of the General Plan on the Districting Maps. Said maps together with all legends, indices and explanatory notes thereon are hereby made a part of these codes. It is further provided that adjustments and changes may be made hereafter in the boundaries of said zones by the Building Officer to implement the Safety Element of the General Plan as additional geologic or subgrade data is made public.
For the purposes of these codes, all construction within the scope of these codes that is within a Land Hazard Zone shall be subject to special design requirements, which are necessary to effect the stated purpose of these codes. Special design requirements shall conform to the guidelines of the California Department of Conservation, Division of Mines and Geology.
(Added by Ord. No. 1945CCS § 3, adopted 6/8/99; amended by Ord. No. 2054CCS § 3, adopted 10/8/02; Ord. No. 2244CCS § 3, adopted 11/27/07; Ord. No. 2445CCS § 11, adopted 11/12/13; Ord. No. 2527CCS § 3, adopted 11/22/16; Ord. No. 2623CCS § 4, adopted 10/22/19; Ord. No. 2727CCS § 4, adopted 10/25/22)
Section 1505.1 of the California Building Code is amended to read as follows:
All roofs shall be Class A or B roofing assemblies in accordance with the Building Code. The use of non-fire-retardant wood shingles or non-fire-retardant shakes for new or replacement roofing is prohibited. Class A or B roof assemblies and roof coverings shall be listed and tested in accordance with ASTM E108 or UL 790. In addition, fire-treated wood roof covering shall be tested in accordance with ASTM D2898.
Section R902.1 of the California Residential Code is amended to read as follows:
Roofs shall be covered with materials as set forth in Sections R904 and R905. A minimum Class A or B roofing shall be installed. The use of non-fire-retardant wood shingles or non-fire-retardant shakes for new or replacement roofing is prohibited. Class A or B roofing shall be listed and tested in accordance with UL 790 or ASTM E108.
(Added by Ord. No. 2054CCS § 3, adopted 10/8/02; amended by Ord. No. 2244CCS § 3, adopted 11/27/07; Ord. No. 2445CCS § 11, adopted 11/12/13; Ord. No. 2527CCS § 3, adopted 11/22/16; Ord. No. 2623CCS § 4, adopted 10/22/19; Ord. No. 2727CCS § 4, adopted 10/25/22)
(a) 
Rooftop Coverings. Section 1507.3.1 of the California Building Code is amended to read as follows:
1507.3.1 Deck Requirements. Concrete and clay tile shall be installed only over solid structural sheathing.
(b) 
Building Separations. Section 1613.5.3 is added to Chapter 16 of the California Building Code to read as follows:
1613.5.3. Modify ASCE 7 Equation 12.12-1 of Section 12.12.3 to read as follows:
δM = Cd δmax
(12.12-1)
(c) 
Vertical Combination of Lateral Force Resisting Systems. Sections 1613.5 and 1613.5.1 are added to Chapter 16 of the California Building Code to read as follows:
1613.5 Amendments to ASCE 7. The provisions of Section 1613.5 shall be permitted as an amendment to the relevant provisions of ASCE 7.
1613.5.1 Values for vertical combinations. Modify ASCE 7 Section 12.2.3.1 Exception 3 to read as follows:
3. 
Detached one- and two-family dwellings up to two stories in height of light frame construction.
(d) 
Subdiaphragm Design. Section 1613.5.2 is added to Chapter 16 of the California Building Code to read as follows:
1613.5.2 Wood Diaphragms. Modify ASCE 7, Section 12.11.2.2.3 to read as follows:
12.11.2.2.3 Wood Diaphragms. In wood diaphragms, the continuous ties shall be in addition to the diaphragm sheathing. Anchorage shall not be accomplished by use of toe nails or nails subject to withdrawal nor shall wood ledgers or framing be used in cross-grain bending or cross-grain tension. The diaphragm sheathing shall not be considered effective as providing ties or struts required by this section.
For structures assigned to Seismic Design Category D, E or F, wood diaphragms supporting concrete or masonry walls shall comply with the following:
1. 
The spacing of continuous ties shall not exceed 40 feet. Added chords of diaphragms may be used to form subdiaphragms to transmit the anchorage forces to the main continuous crossties.
2. 
The maximum diaphragm shear used to determine the depth of the subdiaphragm shall not exceed 75% of the maximum diaphragm shear.
(e) 
Hillside Building. Section 1613.6 is added to Chapter 16 of the California Building Code to read as follows:
1613.6 Seismic Design Provisions for Hillside Buildings.
1613.6.1 Purpose. The purpose of this section is to establish minimum regulations for the design and construction of new buildings and additions to existing buildings when constructing such buildings on or into slopes steeper than one unit vertical in three units horizontal (33.3%). These regulations establish minimum standards for seismic force resistance to reduce the risk of injury or loss of life in the event of earthquakes.
1613.6.2 Scope. The provisions of this section shall apply to the design of the lateral-force-resisting system for hillside buildings at and below the base level diaphragm. The design of the lateral-force-resisting system above the base level diaphragm shall be in accordance with the provisions for seismic and wind design as required elsewhere in this division.
Exception: Non-habitable accessory buildings and decks not supporting or supported from the main building are exempt from these regulations.
1613.6.3 Definitions. For the purposes of this section certain terms are defined as follows:
BASE LEVEL DIAPHRAGM is the floor at, or closest to, the top of the highest level of the foundation.
DIAPHRAGM ANCHORS are assemblies that connect a diaphragm to the adjacent foundation at the uphill diaphragm edge.
DOWNHILL DIRECTION is the descending direction of the slope approximately perpendicular to the slope contours.
FOUNDATION is concrete or masonry which supports a building, including footings, stem walls, retaining walls, and grade beams.
FOUNDATION EXTENDING IN THE DOWNHILL DIRECTION is a foundation running downhill and approximately perpendicular to the uphill foundation.
HILLSIDE BUILDING is any building or portion thereof constructed on or into a slope steeper than one unit vertical in three units horizontal (33.3%). If only a portion of the building is supported on or into the slope, these regulations apply to the entire building.
PRIMARY ANCHORS are diaphragm anchors designed for and providing a direct connection as described in Sections 1613.6.5 and 1613.6.7.3 between the diaphragm and the uphill foundation.
SECONDARY ANCHORS are diaphragm anchors designed for and providing a redundant diaphragm to foundation connection, as described in Sections 1613.6.6 and 1613.6.7.4.
UPHILL DIAPHRAGM EDGE is the edge of the diaphragm adjacent and closest to the highest ground level at the perimeter of the diaphragm.
UPHILL FOUNDATION is the foundation parallel and closest to the uphill diaphragm edge.
1613.6.4 Analysis and Design.
1613.6.4.1 General. Every hillside building within the scope of this section shall be analyzed, designed, and constructed in accordance with the provisions of this division. When the code-prescribed wind design produces greater effects, the wind design shall govern, but detailing requirements and limitations prescribed in this and referenced sections shall be followed.
1613.6.4.2 Base Level Diaphragm-Downhill Direction. The following provisions shall apply to the seismic analysis and design of the connections for the base level diaphragm in the downhill direction.
1613.6.4.2.1 Base for Lateral Force Design Defined. For seismic forces acting in the downhill direction, the base of the building shall be the floor at or closest to the top of the highest level of the foundation.
1613.6.4.2.2 Base Shear. In developing the base shear for seismic design, the response modification coefficient (R) shall not exceed 5 for bearing wall and building frame systems. The total base shear shall include the forces tributary to the base level diaphragm including forces from the base level diaphragm.
1613.6.5 Base Shear Resistance-Primary Anchors.
1613.6.5.1 General. The base shear in the downhill direction shall be resisted through primary anchors from diaphragm struts provided in the base level diaphragm to the foundation.
1613.6.5.2 Location of Primary Anchors. A primary anchor and diaphragm strut shall be provided in line with each foundation extending in the downhill direction. Primary anchors and diaphragm struts shall also be provided where interior vertical lateral-force-resisting elements occur above and in contact with the base level diaphragm. The spacing of primary anchors and diaphragm struts or collectors shall in no case exceed 30 feet (9144 mm).
1613.6.5.3 Design of Primary Anchors and Diaphragm Struts. Primary anchors and diaphragm struts shall be designed in accordance with the requirements of Section 1613.6.8.
1613.6.5.4 Limitations. The following lateral-force-resisting elements shall not be designed to resist seismic forces below the base level diaphragm in the downhill direction:
1.
Wood structural panel wall sheathing,
2.
Cement plaster and lath,
3.
Gypsum wallboard, and
4.
Tension only braced frames.
Braced frames designed in accordance with the requirements of Section 2205.2.1.2 may be used to transfer forces from the primary anchors and diaphragm struts to the foundation provided lateral forces do not induce flexural stresses in any member of the frame or in the diaphragm struts. Deflections of frames shall account for the variation in slope of diagonal members when the frame is not rectangular.
1613.6.6. Base Shear Resistance-Secondary Anchors.
1613.6.6.1 General. In addition to the primary anchors required by Section 1613.6.5, the base shear in the downhill direction shall be resisted through secondary anchors in the uphill foundation connected to diaphragm struts in the base level diaphragm.
Exception: Secondary anchors are not required where foundations extending in the downhill direction spaced at not more than 30 feet (9144 mm) on center extend up to and are directly connected to the base level diaphragm for at least 70% of the diaphragm depth.
1613.6.6.2 Secondary Anchor Capacity and Spacing. Secondary anchors at the base level diaphragm shall be designed for a minimum force equal to the base shear, including forces tributary to the base level diaphragm, but not less than 600 pounds per lineal foot (8.76 kN/m) based on Allowable Stress Design (ASD) levels. The secondary anchors shall be uniformly distributed along the uphill diaphragm edge and shall be spaced a maximum of four feet (1219 mm) on center.
1613.6.6.3 Design. Secondary anchors and diaphragm struts shall be designed in accordance with Section 1613.6.8.
1613.6.7 Diaphragms Below the Base Level-Downhill Direction. The following provisions shall apply to the lateral analysis and design of the connections for all diaphragms below the base level diaphragm in the downhill direction.
1613.6.7.1 Diaphragm Defined. Every floor level below the base level diaphragm shall be designed as a diaphragm.
1613.6.7.2 Design Force. Each diaphragm below the base level diaphragm shall be designed for all tributary loads at that level using a minimum seismic force factor not less than the base shear coefficient.
1613.6.7.3 Design Force Resistance-Primary Anchors. The design force described in Section 1613.6.7.2 shall be resisted through primary anchors from diaphragm struts provided in each diaphragm to the foundation. Primary anchors shall be provided and designed in accordance with the requirements and limitations of Section 1613.6.5.
1613.6.7.4 Design Force Resistance-Secondary Anchors.
1613.6.7.4.1 General. In addition to the primary anchors required in Section 1613.6.7.3, the design force in the downhill direction shall be resisted through secondary anchors in the uphill foundation connected to diaphragm struts in each diaphragm below the base level.
Exception: Secondary anchors are not required where foundations extending in the downhill direction, spaced at not more than 30 feet (9144 mm) on center, extend up to and are directly connected to each diaphragm below the base level for at least 70% of the diaphragm depth.
1613.6.7.4.2 Secondary Anchor Capacity. Secondary anchors at each diaphragm below the base level diaphragm shall be designed for a minimum force equal to the design force but not less than 300 pounds per lineal foot (4.38 kN/m) based on Allowable Stress Design (ASD) levels. The secondary anchors shall be uniformly distributed along the uphill diaphragm edge and shall be spaced a maximum of four feet (1219 mm) on center.
1613.6.7.4.3 Design. Secondary anchors and diaphragm struts shall be designed in accordance with Section 1613.6.8.
1613.6.8 Primary and Secondary Anchorage and Diaphragm Strut Design. Primary and secondary anchors and diaphragm struts shall be designed in accordance with the following provisions:
1.
Fasteners. All bolted fasteners used to develop connections to wood members shall be provided with square plate washers at all bolt heads and nuts. Washers shall be minimum 0.229 inch by 3 inches by 3 inches (5.82 mm by 76 mm by 76 mm) in size. Nuts shall be tightened to finger tight plus 1/2 wrench turn prior to covering the framing.
2.
Fastening. The diaphragm to foundation anchorage shall not be accomplished by the use of toenailing, nails subject to withdrawal, or wood in cross-grain bending or cross-grain tension.
3.
Size of Wood Members. Wood diaphragm struts collectors, and other wood members connected to primary anchors shall not be less than three-inch (76 mm) nominal width. The effects of eccentricity on wood members shall be evaluated as required per Item 9.
4.
Design. Primary and secondary anchorage, including diaphragm struts, splices, and collectors shall be designed for 125% of the tributary force.
5.
Allowable Stress Increase. The one-third allowable stress increase permitted under Section 1605.3.2 shall not be taken when the working (allowable) stress design method is used.
6.
Steel Element of Structural Wall Anchorage System. The strength design forces for steel elements of the structural wall anchorage system, with the exception of anchor bolts and reinforcing steel, shall be increased by 1.4 times the forces otherwise required.
7.
Primary Anchors. The load path for primary anchors and diaphragm struts shall be fully developed into the diaphragm and into the foundation. The foundation must be shown to be adequate to resist the concentrated loads from the primary anchors.
8.
Secondary Anchors. The load path for secondary anchors and diaphragm struts shall be fully developed in the diaphragm but need not be developed beyond the connection to the foundation.
9.
Symmetry. All lateral force foundation anchorage and diaphragm strut connections shall be symmetrical. Eccentric connections may be permitted when demonstrated by calculation or tests that all components of force have been provided for in the structural analysis or tests.
10.
Wood Ledgers. Wood ledgers shall not be used to resist cross-grain bending or cross-grain tension.
1613.6.9 Lateral-Force-Resisting Elements Normal to the Downhill Direction.
1613.6.9.1 General. In the direction normal to the downhill direction, lateral-force-resisting elements shall be designed in accordance with the requirements of this section.
1613.6.9.2 Base Shear. In developing the base shear for seismic design, the response modification coefficient (R) shall not exceed 5 for bearing wall and building frame systems.
1613.6.9.3 Vertical Distribution of Seismic Forces. For seismic forces acting normal to the downhill direction the distribution of seismic forces over the height of the building using Section 12.8.3 of ASCE 7 shall be determined using the height measured from the top of the lowest level of the building foundation.
1613.6.9.4 Drift Limitations. The story drift below the base level diaphragm shall not exceed 0.007 times the story height at strength design force level. The total drift from the base level diaphragm to the top of the foundation shall not exceed 3/4 inch (19 mm). Where the story height or the height from the base level diaphragm to the top of the foundation varies because of a stepped footing or story offset, the height shall be measured from the average height of the top of the foundation. The story drift shall not be reduced by the effect of horizontal diaphragm stiffness.
1613.6.9.5 Distribution of Lateral Forces.
1613.6.9.5.1 General. The design lateral force shall be distributed to lateral-force-resisting elements of varying heights in accordance with the stiffness of each individual element.
1613.6.9.5.2 Wood Structural Panel Sheathed Walls. The stiffness of a stepped wood structural panel shear wall may be determined by dividing the wall into adjacent rectangular elements, subject to the same top of wall deflection. Deflections of shear walls may be estimated by AWC SDPWS Section 4.3.2. Sheathing and fastening requirements for the stiffest section shall be used for the entire wall. Each section of wall shall be anchored for shear and uplift at each step. The minimum horizontal length of a step shall be eight feet (2438 mm) and the maximum vertical height of a step shall be two feet, eight inches (813 mm).
1613.6.9.5.3 Reinforced Concrete or Masonry Shear Walls. Reinforced concrete or masonry shear walls shall have forces distributed in proportion to the rigidity of each section of the wall.
1613.6.9.6 Limitations. The following lateral force-resisting-elements shall not be designed to resist lateral forces below the base level diaphragm in the direction normal to the downhill direction:
1.
Cement plaster and lath,
2.
Gypsum wallboard, and
3.
Tension-only braced frames.
Braced frames designed in accordance with the requirements of Section 2205.2.1.2 of this Code may be designed as lateral-force-resisting elements in the direction normal to the downhill direction, provided lateral forces do not induce flexural stresses in any member of the frame. Deflections of frames shall account for the variation in slope of diagonal members when the frame is not rectangular.
1613.6.10 Specific Design Provisions.
1613.6.10.1 Footings and Grade Beams. All footings and grade beams shall comply with the following:
1.
Grade beams shall extend at least 12 inches (305 mm) below the lowest adjacent grade and provide a minimum 24-inch (610 mm) distance horizontally from the bottom outside face of the grade beam to the face of the descending slope.
2.
Continuous footings shall be reinforced with at least two No. 4 reinforcing bars at the top and two No. 4 reinforcing bars at the bottom.
3.
All main footing and grade beam reinforcement steel shall be bent into the intersecting footing and fully developed around each corner and intersection.
4.
All concrete stem walls shall extend from the foundation and reinforced as required for concrete or masonry walls.
1613.6.10.2 Protection Against Decay and Termites. All wood to earth separation shall comply with the following:
1.
Where a footing or grade beam extends across a descending slope, the stem wall, grade beam, or footing shall extend up to a minimum 18 inches (457 mm) above the highest adjacent grade.
Exception: At paved garage and doorway entrances to the building, the stem wall need only extend to the finished concrete slab, provided the wood framing is protected with a moisture proof barrier.
2.
Wood ledgers supporting a vertical load of more than 100 pounds per lineal foot (1.46 kN/m) based on Allowable Stress Design (ASD) levels and located within 48 inches (1219 mm) of adjacent grade are prohibited. Galvanized steel ledgers and anchor bolts, with or without wood nailers, or treated or decay resistant sill plates supported on a concrete or masonry seat, may be used.
1613.6.10.3 Sill Plates. All sill plates and anchorage shall comply with the following:
1.
All wood framed walls, including nonbearing walls, when resting on a footing, foundation, or grade beam stem wall, shall be supported on wood sill plates bearing on a level surface.
2.
Power-driven fasteners shall not be used to anchor sill plates except at interior nonbearing walls not designed as shear walls.
1613.6.10.4 Column Base Plate Anchorage. The base of isolated wood posts (not framed into a stud wall) supporting a vertical load of 4,000 pounds (17.8 kN) based on Allowable Stress Design (ASD) levels or more and the base plate for a steel column shall comply with the following:
1.
When the post or column is supported on a pedestal extending above the top of a footing or grade beam, the pedestal shall be designed and reinforced as required for concrete or masonry columns. The pedestal shall be reinforced with a minimum of four No. 4 bars extending to the bottom of the footing or grade beam. The top of exterior pedestals shall be sloped for positive drainage.
2.
The base plate anchor bolts or the embedded portion of the post base, and the vertical reinforcing bars for the pedestal, shall be confined with two No. 4 or three No. 3 ties within the top five inches (127 mm) of the concrete or masonry pedestal. The base plate anchor bolts shall be embedded a minimum of 20 bolt diameters into the concrete or masonry pedestal. The base plate anchor bolts and post bases shall be galvanized and each anchor bolt shall have at least two galvanized nuts above the base plate.
1613.6.10.5 Steel Beam to Column Supports. All steel beam to column supports shall be positively braced in each direction. Steel beams shall have stiffener plates installed on each side of the beam web at the column. The stiffener plates shall be welded to each beam flange and the beam web. Each brace connection or structural member shall consist of at least two 5/8 inch (15.9 mm) diameter machine bolts.
(f) 
Suspended Ceilings. Add Section 1613.7 to Chapter 16 of the California Building Code to read as follows:
1613.7 Suspended Ceilings. Minimum design and installation standards for suspended ceilings shall be determined in accordance with the requirements of Section 2506.2.1 of this Code and this subsection.
1613.7.1 Scope. This part contains special requirements for suspended ceilings and lighting systems. Provisions of Section 13.5.6 of ASCE 7 shall apply except as modified herein.
1613.7.2 General. The suspended ceilings and lighting systems shall be limited to 6 feet (1,828 mm) below the structural deck unless the lateral bracing is designed by a licensed engineer or architect.
1613.7.3 Sprinkler Heads. All sprinkler heads (drops) except fire-resistance-rated floor/ceiling or roof/ceiling assemblies, shall be designed to allow for free movement of the sprinkler pipes with oversize rings, sleeves or adaptors through the ceiling tile. Sprinkler heads and other penetration shall have a 2-inch (50 mm) oversize ring, sleeve, or adapter through the ceiling tile to allow for free movement of at least 1-inch (25 mm) in all horizontal directions. Alternatively, a swing joint that can accommodate 1-inch (25 mm) of ceiling movement in all horizontal directions is permitted to be provided at the top of the sprinkler head extension.
Sprinkler heads penetrating fire-resistance-rated floor/ceiling or roof/ceiling assemblies shall comply with Section 714 of this Code.
1613.7.4 Special Requirements for Means of Egress. Suspended ceiling assemblies located along means of egress serving an occupant load of 30 or more shall comply with the following provisions.
1613.7.4.1 General. Ceiling suspension systems shall be connected and braced with vertical hangers attached directly to the structural deck along the means of egress serving an occupant load of 30 or more and at lobbies accessory to Group A Occupancies. Spacing of vertical hangers shall not exceed 2 feet (610 mm) on center along the entire length of the suspended ceiling assembly located along the means of egress or at the lobby.
1613.7.4.2 Assembly Device. All lay-in panels shall be secured to the suspension ceiling assembly with two hold-down clips minimum for each tile within a 4-foot (1,219 mm) radius of the exit lights and exit signs.
1613.7.4.3 Emergency Systems. Independent supports and braces shall be provided for light fixtures required for exit illumination. Power supply for exit illumination shall comply with the requirements of Section 1008.3 of this Code.
1613.7.4.4 Support for Appendages. Separate support from the structural deck shall be provided for all appendages such as light fixtures, air diffusers, exit signs, and similar elements.
(Added by Ord. No. 2445CCS § 11, adopted 11/12/13; amended by Ord. No. 2527CCS § 3, adopted 11/22/16; Ord. No. 2623CCS § 4, adopted 10/22/19; Ord. No. 2727CCS § 4, adopted 10/25/22)
(a) 
Structural Observation—General. Amend Section 1704.6 of the California Building Code to read as follows:
1704.6 Structural Observations. Where required by the provisions of Section 1704.6.1, 1704.6.2, or 1704.6.3, the owner or the owner's authorized agent shall employ a structural observer to perform structural observations. Structural observation does not include or waive the responsibility for the inspections in Section 110 or the special inspections in Section 1705 or the other section of this code. The structural observer shall be one of the following individuals:
1. 
The registered design professional responsible for the structural design, or
2. 
A registered design professional designated by the registered design professional responsible for the structural design.
Prior to the commencement of observations, the structural observer shall submit to the building official a written statement identifying the frequency and extent of structural observations.
The owner or owner's authorized agent shall coordinate and call a preconstruction meeting between the structural observer, contractors, affected subcontractors and special inspectors. The structural observer shall preside over the meeting. The purpose of the meeting shall be to identify the major structural elements and connections that affect the vertical and lateral load resisting systems of the structure and to review scheduling of the required observations. A record of the meeting shall be included in the report submitted to the Building Official.
Observed deficiencies shall be reported in writing to the owner or owner's authorized agent, special inspector, contractor and the Building Official. Upon the form prescribed by the Building Official, the structural observer shall submit to the Building Official a written statement at each significant construction stage stating that the site visits have been made and identifying any reported deficiencies which, to the best of the structural observer's knowledge, have not been resolved. A final report by the structural observer which states that all observed deficiencies have been resolved is required before acceptance of the work by the Building Official.
(b) 
Structural Observation—Seismic. Amend Section 1704.6.2 of the California Building Code to read as follows:
1704.6.2 Structural Observation for Seismic Resistance. Structural observations shall be provided for those structures assigned to Seismic Design Category D, E or F, where one or more of the following conditions exist:
1. 
The structure is classified as Risk Category III or IV.
2. 
The structure is a high-rise building.
3. 
The structure is classified as Risk Category I or II, and a lateral design is required for the structure or portion thereof.
4. 
Such observation is required by the registered design professional responsible for the structural design.
5. 
Such observation is specifically required by the Building Official.
Exception: One-story wood framed Group R-3 and Group U Occupancies less than 2,000 square feet in area, provided the adjacent grade is not steeper than 1 unit vertical in 10 units horizontal (10% sloped), assigned to Seismic Design Category D.
As applied to this Section, a registered design professional is an individual who is registered and licensed in the State of California as a Civil Engineer, Structural Engineer or Architect by the California Board of Professional Engineers, Land Surveyors and Geologists or the California Architects Board.
(c) 
Special Inspection for Concrete Construction. Amend Section 1705.3 of the California Building Code to read as follows:
1705.3 Concrete Construction. The special inspections and tests for concrete construction shall be as required by this section and Table 1705.3.
Exceptions: Special inspections and tests shall not be required for:
1. 
Isolated spread concrete footings of buildings three stories or less above grade plane that are fully supported on earth or rock, where the structural design of the footing is based on a specified compressive strength, f'c, no greater than 2,500 pounds per square inch (psi) (17.2 MPa) regardless of the compressive strength specific in the construction documents or used in the footing construction.
2. 
Continuous concrete footings supporting walls of buildings three stories or less in height that are fully supported on earth or rock where:
2.1. 
The footings support walls of light-frame construction;
2.2. 
The footings are designed in accordance with Table 1809.7 or
2.3. 
The structural design of the footing is based on a specified compressive strength, f'c, no greater than 2,500 pounds per square inch (psi) (17.2 MPa), regardless of the compressive strength specified in the construction documents or used in the footing construction.
3. 
Nonstructural concrete slabs supported directly on the ground, including prestressed slabs on grade, where the effective prestress in the concrete is less than 150 psi (1.03 MPa).
4. 
Concrete patios, driveways and sidewalks, on grade.
TABLE 1705.3
REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION
-Image-1.tif
(d) 
Special Inspection for Seismic Resistance. Amend Section 1705.13 of the California Building Code to read as follows:
1705.13 Special Inspection for Seismic Resistance. Special inspections for seismic resistance shall be required as specified in Sections 1705.13.1 through 1705.13.9, unless exempted by the exceptions of Section 1704.2.
Exception: Special inspections itemized in Sections 1705.13.1 through 1705.13.9 are not required for structures designed and constructed in accordance with one of the following:
1. 
The structure consists of light-frame construction; the design spectral response acceleration at short periods, SDS, as determined in Section 1613.2.4, does not exceed 0.5 g; and the building height of the structure does not exceed 35 feet (10,668 mm) above grade plane; or
2. 
The seismic force-resisting system of the structure consists for reinforced masonry or reinforced concrete; the design spectral response acceleration at short periods, SDS, as determined in Section 1613.2.4, does not exceed 0.5; and the building height of the structure does not exceed 25 feet (7,620 mm);
3. 
Detached one- or two-family dwellings not exceeding two stories above grade plane, provided the structure is not assigned to Seismic Design Category D, E or F and does not have any of the following horizontal or vertical irregularities in accordance with Section 12.3 of ASCE 7:
3.1 
Torsional or extreme torsional irregularity.
3.2 
Nonparallel systems irregularity.
3.3 
Stiffness irregularity—extreme soft story and soft story.
3.4 
Discontinuity in lateral strength—weak story irregularity.
(Added by Ord. No. 2445CCS § 11, adopted 11/12/13; amended by Ord. No. 2527CCS § 3, adopted 11/22/16; Ord. No. 2623CCS § 4, adopted 10/22/19; Ord. No. 2727CCS § 4, adopted 10/25/22)
(a) 
Permanent Wood Foundation Systems. Amend Section 1807.1.4 of the California Building Code to read as follows:
1807.1.4 Permanent Wood Foundations Systems. Permanent wood foundation systems shall be designed and installed in accordance with AWC PWF. Lumber and plywood shall be treated in accordance with AWPA U1 (Commodity Specification A, Special Requirement 4.2) and shall be identified in accordance with Section 2303.1.9.1. Permanent wood foundation systems shall not be used for structures assigned to Seismic Design Category D, E or F.
(b) 
Prescriptive Design of Foundation Walls. Amend Section 1807.1.6 of the California Building Code to read as follows:
1807.1.6 Prescriptive Design of Concrete and Masonry Foundation Walls. Prescriptive design of concreate and masonry foundation walls. Concrete and masonry foundation walls that are laterally supported at the top and bottom shall be permitted to be designed and constructed in accordance with this section. Prescriptive design of foundation walls shall not be used for structures assigned to Seismic Design Category D, E or F.
(c) 
General. Amend Section 1809.3 of the California Building Code to read as follows:
1809.3 Stepped Footings. The top surface of footings shall be level. The bottom surface of footings is permitted to have a slope not exceeding one unit vertical in ten units horizontal (ten percent slope). Footings shall be stepped where it is necessary to change the elevation of the top surface of the footing or where the surface of the ground slopes more than one unit vertical in ten units horizontal (ten percent slope).
For structures assigned to Seismic Design Category D, E or F, the stepping requirement shall also apply to the top surface of grade beams supporting walls. Footings shall be reinforced with four No. 4 rebar. Two bars shall be placed at the top and bottom of the footings as shown in Figure 1809.3.
-Image-2.tif
FIGURE 1809.3
STEPPED FOOTING
(d) 
Prescriptive Footings. Amend Section 1809.7 and Table 1809.7 of the California Building Code to read as follows:
1809.7 Prescriptive Footings for Light-Frame Construction. Where a specific design is not provided, concrete or masonry-unit footings supporting walls of light-frame construction shall be permitted to be designed in accordance with Table 1809.7 Prescriptive footings in Table 1809.7 shall not exceed one story above grade plane for structures assigned to Seismic Design Category D, E or F.
TABLE 1809.7
PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTION a, b, c, d, e
NUMBER OF FLOORS SUPPORTED BY THE FOOTINGe
WIDTH OF FOOTING
(inches)
THICKNESS OF FOOTING
(inches)
1
12
6
2
15
6
3
18
8
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm
a.
Depth of footings shall be in accordance with Section 1809.4.
b.
The ground under the floor shall be permitted to be excavated to the elevation of the top of the footing.
c.
See Section 1905 for additional requirements for concrete footings of structures assigned to Seismic Design Category C, D, E or F.
d.
For thickness of foundation walls, see Section 1807.1.6.
e.
Footings shall be permitted to support a roof addition to the stipulated number of floors. Footings supporting roof only shall be as required for supporting one floor.
(e) 
Timber Footings. Amend Section 1809.12 of the California Building Code to read as follows:
1809.12 Timber Footings. Timber footings shall be permitted for buildings of Type V construction and as otherwise approved by the Building Official. Such footings shall be treated in accordance with AWPA U1 (Commodity Specification A, Use Category 4B). Treated timbers are not required where placed entirely below permanent water level, or where used as capping for wood piles that project above the water level over submerged or marsh lands. The compressive stresses perpendicular to grain in untreated timber footings supported on treated piles shall not exceed 70 percent of the allowable stresses for the species and grade of timber as specified in the ANSI/AWC NDS. Timber footings shall not be used in structures assigned to Seismic Design Category D, E or F.
(f) 
Timber. Amend Section 1810.3.2.4 of the California Building Code to read as follows:
1810.3.2.4 Timber. Timber deep foundation elements shall be designed as piles or poles in accordance with ANSI/AWC NDS. Round timber elements shall conform to ASTM D 25. Sawn timber elements shall conform to DOC PS-20. Timber deep foundation elements shall not be used in structures assigned to Seismic Design Category D, E or F.
(g) 
Embedded Posts and Poles. Section 1807.3.1 of the California Building Code is amended to read as follows:
1807.3.1 Limitations. The design procedures outlined in this section are subject to the following limitations:
1. 
The frictional resistance for structural walls and slabs on silts and clays shall be limited to one-half of the normal force imposed on the soils by the weight of the fooling or slab.
2. 
Posts embedded in earth shall not be used to provide lateral support for structural or nonstructural materials such as plaster, masonry or concrete unless bracing is provided that develops the limited deflection required.
Wood poles shall be treated in accordance with AWPA U1 for sawn timber posts (Commodity Specification A, Use Category 4B) and for round timber posts (Commodity Specification B, Use Category 4B). Wood poles and posts embedded in direct contact with soil shall not be used for structures assigned to Seismic Design Category D, E or F.
Exception: Wood poles and posts embedded in direct contact with soil may be used to support nonhabitable, nonoccupiable structures such as fences when approved by the building official.
(Added by Ord. No. 2445CCS § 11, adopted 11/12/13; amended by Ord. No. 2527CCS § 3, adopted 11/22/16; Ord. No. 2623CCS § 4, adopted 10/22/19; Ord. No. 2727CCS § 4, adopted 10/25/22)
(a) 
Minimum Reinforcement. Amend Section 1905.1.7 of the 2022 California Building Code to read as follows:
1905.1.7 ACI 318, Section 14.1.4. Delete ACI 318, Section 14.1.4, and replace with the following:
14.1.4. Plain concrete in structures assigned to Seismic Design Category C, D, E or F.
14.1.4.1. Structures assigned to Seismic Design Category C, D, E or F shall not have elements of structural plain concrete, except as follows:
(a)
Concrete used for fill with a minimum cement content of two sacks of Portland cement or cementious material per cubic yard.
(b)
Isolated footings of plain concrete supporting pedestals or columns are permitted, provided the projection of the footing beyond the face of the supported member does not exceed the footing thickness.
(c)
Plain concrete footings supporting walls are permitted provided the footings have at least two continuous longitudinal reinforcing bars. Bars shall not be smaller than No. 4 and shall have a total area of not less than 0.002 times the gross cross-sectional area of the footing. A minimum of one bar shall be provided at the top and bottom of the footing. Continuity of reinforcement shall be provided at corners and intersections.
Exceptions:
1.
Detached one- and two-family dwellings three stories or less in height and constructed with stud-bearing walls, are permitted to have plain concrete footings with at least two continuous longitudinal reinforcing bars not smaller than No. 4 are permitted to have a total area of less than 0.002 times the gross cross-sectional area of the footing.
(b) 
Reinforcement. Amend Section 1905.1 to read as shown below and add Sections 1905.1.9 through 1905.1.11 to Chapter 19 of the California Building Code to read as follows:
(1) 
1905.1 General. The text of ACI 318 shall be modified as indicated in Sections 1905.1.1 through 1905.1.11.
1905.1.9 ACI 318, Section 18.7.5. Modify ACI 318, Section 18.7.5, by adding Section 18.7.5.7 and 18.7.5.8 as follows:
18.7.5.7 Where the calculated point of contraflexure is not within the middle half of the member clear height, provide transverse reinforcement as specified in ACI 318 Section 18.7.5.1, Items (a) through (c), over the full height of the member.
18.7.5.8 At any section where the design strength, fPn, of the column is less than the sum of the shears Ve computed in accordance with ACI 318 Sections 18.7.6.1 and 18.6.5.1 for all the beams framing into the column above the level under consideration, transverse reinforcement as specified in ACI 318 Sections 18.7.5.1 through 18.7.5.3 shall be provided. For beams framing into opposite sides of the column, the moment components are permitted to be assumed to be of opposite sign. For the determination of the design strength, fPn, of the column, these moments are permitted to be assumed to result from the deformation of the frame in any one principal axis.
1905.1.10 ACI 318, Section 18.10.4. Modify ACI 318, Section 18.10.4, by adding Section 18.10.4.6 as follows:
18.10.4.6 Walls and portions of walls with Pu > 0.35Po shall not be considered to contribute to the calculated shear strength of the structure for resisting earthquake-induced forces. Such walls shall conform to the requirements of ACI 318 Section 18.14.
1905.1.11 ACI 318, Section 18.12.6. Modify ACI 318, by adding Section 18.12.6.2 as follows:
18.12.6.2 Collector and boundary elements in topping slabs placed over precast floor and roof elements shall not be less than 3 inches (76 mm) or 6 db in thickness, where db is the diameter of the largest reinforcement in the topping slab.
(Added by Ord. No. 2445CCS § 11, adopted 11/12/13; amended by Ord. No. 2527CCS § 3, adopted 11/22/16; Ord. No. 2623CCS § 4, adopted 10/22/19; Ord. No. 2727CCS § 4, adopted 10/25/22)
(a) 
Existing Concrete and Masonry Fireplaces and Chimneys. Where construction work of any kind is on the same wall or plane as an existing concrete or masonry fireplace and/or chimney, and where the fireplace and/or chimney does not meet the requirements of the current California Building Code, the fireplace and/or chimney shall:
(1) 
Be retrofitted, to meet a minimum of seventy-five percent of the design load requirements in the California Building Code and in accordance with all applicable laws, including the City's Zoning, and Landmark and Historic Preservation laws;
(2) 
Be demolished, in accordance with all applicable laws, including the City's Zoning, and Landmark and Historic Preservation laws.
(Added by Ord. No. 2445CCS § 11, adopted 11/12/13; amended by Ord. No. 2527CCS § 3, adopted 11/22/16; Ord. No. 2623CCS § 4, adopted 10/22/19; Ord. No. 2727CCS § 4, adopted 10/25/22)
(a) 
Fastener Requirements. Amend Section 2304.10.2 of the California Building Code to read as follows:
2304.10.2 Fastener Requirements. Connections for wood members shall be designed in accordance with he appropriate methodology in Section 2302.1. The number and size of fasteners connecting wood members shall not be less than that set forth in Table 2304.10.1. Staple fasteners in Table 2304.10.2 shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F.
Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values are substantiated by cyclic testing and approved by the building official.
(b) 
Wood Used in Retaining Wall and Cribs. Amend Section 2304.12.8 of the California Building Code to read as follows:
2304.12.8 Wood Used in Retaining Walls and Cribs. Wood used in retaining walls and cribs. Wood installed in retaining or crib walls shall be preservative treated in accordance with AWPA U1 for soil and fresh water use. Wood shall not be used in retaining or crib walls for structures assigned to Seismic Design Category D, E or F.
(c) 
Quality of Nails. Section 2304.10.3.1 is added to Chapter 23 of the California Building Code to read as follows:
2304.10.3.1 Quality of Nails. In Seismic Design Category D, E or F, mechanically driven nails used in wood structural panel shear walls shall meet the same dimensions as that required for hand-driven nails, including diameter, minimum length and minimum head diameter. Clipped head or box nails are not permitted in new construction. The allowable design value for clipped head nails in existing construction may be taken at no more than the nail-head-area ratio of that of the same size hand-driven nails.
(d) 
Hold-Down Connectors. Section 2305.4 is added to Chapter 23 of the California Building Code to read as follows:
2305.4 Hold-Down Connectors. In Seismic Design Category D, E or F, hold-down connectors shall be designed to resist shear wall overturning moments using approved cyclic load values or 75 percent of the allowable seismic load values that do not consider cyclic loading of the product. Connector bolts into wood framing shall require steel plate washers on the post on the opposite side of the anchorage device. Plate size shall be a minimum of 0.229 inch by 3 inches by 3 inches (5.82 mm by 76 mm by 76 mm) in size. Hold-down connectors shall be tightened to finger tight plus 1/2 wrench turn just prior to covering the wall framing.
(e) 
Wood-Frame Diaphragms. Amend Section 2306.2 of the California Building Code to read as follows:
2306.2 Wood-Frame Diaphragms. Wood-frame diaphragms shall be designed and constructed in accordance with AWC SDPWS. Where panels are fastened to framing members with staples, requirements and limitations of AWC SDPWS shall be met and the allowable shear values set forth in Table 2306.2(1) or 2306.2(2) shall only be permitted for structures assigned to Seismic Design Category A, B, or C.
Exception: Allowable shear values where panels are fastened to framing members with staples may be used if such values are substantiated by cyclic testing and approved by the Building Official.
The allowable shear values in Tables 2306.2(1) and 2306.2(2) are permitted to be increased 40 percent for wind design.
Wood structural panel diaphragms used to resist seismic forces in structures assigned to Seismic Design Category D, E or F shall be applied directly to the framing members.
Exception: Wood structural panel diaphragms are permitted to be fastened over solid lumber planking or laminated decking, provided the panel joints and lumber planking or laminated decking joints do not coincide.
(f) 
Wood Frame Shear Walls. Amend Section 2306.3 and Section 2307.2 of the California Building Code to read as follows:
2306.3 Wood-Frame Shear Walls. Wood-frame shear walls shall be designed and constructed in accordance with AF&PA SDPWS. For structures assigned to Seismic Design Category D, E, or F, application of Tables 4.3A and 4.3B of AWC SDPWS shall include the following:
1.
Wood structural panel thickness for shear walls shall not be less than 3/8 inch thick and studs shall not be spaced at more than 16 inches on center.
2.
The maximum nominal unit shear capacities for 3/8 inch wood structural panels resisting seismic forces in structures assigned to Seismic Design Category D, E or F is 400 pounds per linear foot (plf).
Exception: Other nominal unit shear capacities may be permitted if such values are substantiated by cyclic testing and approved by the Building Official.
3.
Nails shall be placed not less than 1/2-inch in from the panel edges and not less than 3/8-inch from the edge of the connecting members for shear greater than 350 plf using ASD or 500 plf using LRFD. Nails shall be placed not less than 3/8 inch from panel edges and not less than 1/4-inch from the edge of the connecting members for shears of 350 plf or less using ASD or 500 plf or less using LRFD.
For structures assigned to Seismic Design Category D, application of Table 4.3C of AWC SDPWS shall not be used below the top level in a multi-level building.
Where panels are fastened to framing members with staples, requirements and limitations of AWC SDPWS shall be met and the allowable shear values set forth in Table 2306.3(1), 2306.3(2) or 2306.3(3) shall only be permitted for structures assigned to Seismic Design Category A, B, or C.
Exception: Allowable shear values where panels are fastened to framing members with staples may be used if such values are substantiated by cyclic testing and approved by the Building Official.
The allowable shear values in Tables 2306.3(1) and 2306.3(2) are permitted to be increased 40 percent for wind design. Panels complying with ANSI/APA PRP-210 shall be permitted to use design values for Plywood Siding in the AWC SDPWS.
2307.2 Wood-Frame Shear Walls. Wood-frame shear walls shall be designed and constructed in accordance with Section 2306.3 as applicable.
(g) 
Braced Wall Line Support. Amend Section 2308.6.8.1 of the California Building Code to read as follows:
2308.6.8.1 Foundations. Braced wall lines shall be supported by continuous foundations. For structures in Seismic Design Categories D and E, exterior braced wall panels shall be in the same plane vertically with the foundation or the portion of the structure containing the offset shall be designed in accordance with accepted engineering practice and Section 2308.1.1.
Exception: For structures with a maximum plan dimension not more than 50 feet (15240mm), continuous foundations are required at exterior walls only for structures assigned to Seismic Design Category A, B, or C.
(h) 
Alternative Bracing. Amend Section 2308.6.5.1 and Figure 2308.6.5.2 of the California Building Code to read as follows:
2308.6.5.1 Alternate Braced Wall (ABW). An ABW shall be constructed in accordance with this section and Figure 2308.6.5.1. In one-story buildings, each panel shall have a length of not less than 2 feet 8 inches (813 mm) and a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one face with 3/8-inch (3.2 mm) minimum-thickness wood structural panel sheathing nailed with 8d common or galvanized box nails in accordance with Table 2304.10.1 and blocked at wood structural panel edges. For structures assigned to Seismic Design Category D or E, each panel shall be sheathed on one face with 15/32-inch-minimum-thickness (11.9 mm) wood structural panel sheathing nailed with 8d common nails spaced 3 inches on panel edges, 3 inches at intermediate supports. Two anchor bolts installed in accordance with Section 2308.3.1 shall be provided in each panel. Anchor bolts shall be placed at each panel outside quarter points. Each panel end stud shall have a hold-down device fastened to the foundation, capable of providing an approved uplift capacity of not less than 1,800 pounds (8006 N). The hold-down device shall be installed in accordance with the manufacturer's recommendations. The ABW shall be supported directly on a foundation or on floor framing supported directly on a foundation that is continuous across the entire length of the braced wall line. This foundation shall be reinforced with not less than one No. 4 bar top and bottom. Where the continuous foundation is required to have a depth greater than 12 inches (305 mm), a minimum 12-inch by 12-inch (305 mm by 305 mm) continuous footing is permitted at door openings in the braced wall line. This continuous footing shall be reinforced with not less than one No. 4 bar top and bottom. This reinforcement shall be lapped 24 inches (610 mm) with the reinforcement required in the continuous foundation located directly under the braced wall line.
Where the ABW is installed at the first story of two-story buildings, the wood structural panel sheathing shall be provided on both faces, three anchor bolts shall be placed at one-quarter points and tie-down device uplift capacity shall be not less than 3,000 pounds (13,344 N).
-Image-3.tif
FIGURE 2308.6.5.1
ALTERNATE BRACED WALL PANEL (ABW)
2308.6.5.2 Portal Frame with Hold-Downs (PFH). A PFH shall be constructed in accordance with this section and Figure 2308.6.5.2. The adjacent door or window opening shall have a full-length header.
In one-story buildings, each panel shall have a length of not less than 16 inches (406 mm) and a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one face with a single layer of 3/8-inch (9.5 mm) minimum-thickness wood structural panel sheathing nailed with 8d common or galvanized box nails in accordance with Figure 2308.6.5.2. For structures assigned to Seismic Design Category D or E, each panel shall be sheathed on one face with 15/32-inch-minimum-thickness (11.9 mm) wood structural panel sheathing nailed with 8d common nails spaced 3 inches on panel edges, 3 inches at intermediate supports and in accordance with Figure 2308.6.5.2. The wood structural panel sheathing shall extend up over the solid sawn or glued-laminated header and shall be nailed in accordance with Figure 2308.6.5.2. A built-up header consisting of at least two 2-inch by 12-inch (51 mm by 305 mm) boards, fastened in accordance with Item 24 of Table 2304.10.1 shall be permitted to be used. A spacer, if used, shall be placed on the side of the built-up beam opposite the wood structural panel sheathing. The header shall extend between the inside faces of the first full-length outer studs of each panel. The clear span of the header between the inner studs of each panel shall be not less than 6 feet (1829 mm) and not more than 18 feet (5486 mm) in length. A strap with an uplift capacity of not less than 1,000 pounds (4,400 N) shall fasten the header to the inner studs opposite the sheathing. One anchor bolt not less than 5/8 inch (15.9 mm) diameter and installed in accordance with Section 2308.3.1 shall be provided in the center of each sill plate. The studs at each end of the panel shall have a hold-down device fastened to the foundation with an uplift capacity of not less than 3,500 pounds (15570 N).
Where a panel is located on one side of the opening, the header shall extend between the inside face of the first full-length stud of the panel and the bearing studs at the other end of the opening. A strap with an uplift capacity of not less than 1,000 pounds (4400 N) shall fasten the header to the bearing studs. The bearing studs shall also have a hold-down device fastened to the foundation with an uplift capacity of not less than 1,000 pounds (4400 N). The hold-down devices shall be an embedded strap type, installed in accordance with the manufacturer's recommendations. The PFH panels shall be supported directly on a foundation that is continuous across the entire length of the braced wall line. This foundation shall be reinforced with not less than one No.
4 bar top and bottom. Where the continuous foundation is required to have a depth greater than 12 inches (305 mm), a minimum 12-inch by 12-inch (305 mm by 305 mm) continuous footing is permitted at door openings in the braced wall line. This continuous footing shall be reinforced with not less than one No. 4 bar top and bottom. This reinforcement shall be lapped not less than 24 inches (610 mm) with the reinforcement required in the continuous foundation located directly under the braced wall line.
Where a PFH is installed at the first story of two-story buildings, each panel shall have a length of not less than 24 inches (610 mm).
-Image-4.tif
FIGURE 2308.6.5.2
PORTAL FRAME WITH HOLD-DOWNS (PFH)
(i) 
Braced Wall Sheathing. Table 2308.6.1 of the 2022 Edition of the California Building Code is amended to read as follows:
-Image-5.tif
(j) 
Attachment of Sheathing. Amend Section 2308.6.9 of the California Building Code to read as follows:
2308.6.9 Attachment of Sheathing. Fastening of braced wall panel sheathing shall not be less than that prescribed in Table 2308.6.1 or 2304.10.2. Wall sheathing shall not be attached to framing members by adhesives. Staple fasteners in Table 2304.10.2 shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F.
Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values are substantiated by cyclic testing and approved by the Building Official.
All braced wall panels shall extend to the roof sheathing and shall be attached to parallel roof rafters or blocking above with framing clips (18 gauge minimum) spaced at maximum 24 inches (6,096 mm) on center with four 8d nails per leg (total eight 8d nails per clip). Braced wall panels shall be laterally braced at each top corner and at maximum 24-inch (6,096 mm) intervals along the top plate of discontinuous vertical framing.
(k) 
Retaining Walls. Section 1807.2 of the California Building Code is amended to read as follows:
1807.2 Retaining walls. Retaining walls shall be designed in accordance with Sections 1807.2.1 through 1807.2.3. Retaining walls over 4' in height assigned to Seismic Design Category D, E or F shall not be partially or wholly constructed of wood.
(Added by Ord. No. 2445CCS § 11. adopted 11/12/13; amended by Ord. No. 2527CCS § 3, adopted 11/22/16; Ord. No. 2623CCS § 4, adopted 10/22/19; Ord. No. 2727CCS § 4, adopted 10/25/22)
(a) 
Fencing Regulations.
(1) 
Standards for New Enclosures. Every person, firm or corporation owning land on which there is situated a swimming pool, spa, hot tub, pond or other body of water which contains water eighteen inches or more in depth at any point shall completely surround such body of water or property with a fence, wall or other structure not less than five feet above the adjacent grade at all places and with no opening therein more than four inches in maximum dimensions. Any gate in such fence shall have a latch at least five feet above the underlying ground and such gate shall be self-closing and secured when adults are not present.
(2) 
Existing Enclosures. Every person, firm or corporation owning land on which there is situated a swimming pool, pond or other body of water which contains water eighteen inches or more in depth at any point shall completely surround such body of water or property with a fence, wall or other structure not less than four and one-half feet above the adjacent grade at all places and with no opening therein more than four inches in maximum dimensions. Any gate in such fence shall have a latch at least four and one-half feet above the underlying ground and such gate shall be self-closing and secured when adults are not present.
For the purposes of this Section, existing enclosures are those enclosures that were constructed under valid permit issued prior to July 1, 1999.
(3) 
Requirements for Nonconforming Enclosures. When an existing pool enclosure is replaced or repaired in excess of fifty percent of its length, the enclosure shall be made to conform to all of the requirements for a new enclosure under prevailing law.
(4) 
Applicability of Other Codes and Laws. The provisions of this Section are in addition to the pool enclosure requirements for public or private pools as required in Chapter 31 B of the California Building Code.
When conflicting provisions or requirements occur between the provisions of this Section, the Technical Codes, and other codes or laws, the most restrictive provisions or requirements shall govern.
(b) 
Pool Water Clarity. The re-circulation and purification system of any swimming pool, fish pond or any other body of water shall be operated and maintained so as to keep the water in such pool or other body of water clean and of reasonable clarity.
The following standards shall be used to define reasonable clarity of the water in such pool, pond or body of water:
A painted black disk, six inches in diameter on a twelve-inch by twelve-inch white tile, placed at the bottom of the pool at its deepest point, shall be clearly visible from the sidewalks around the pool from all distances up to ten yards from such disk, or the water shall be determined to not be of reasonable clarity.
(Added by Ord. No. 2527CCS § 3, adopted 11/22/16; amended by Ord. No. 2623CCS § 4, adopted 10/22/19; Ord. No. 2727CCS § 4, adopted 10/25/22)
Section 3115 is added to read as follows:
3115 Intermodal Shipping Containers.
3115.1 General. The provisions of Section 3115 and other applicable sections of this code shall apply to intermodal shipping containers that are repurposed for use as buildings or structures or as a part of buildings or structures.
Exceptions:
1.
Intermodal shipping containers previously approved as existing relocatable buildings complying with Chapter 14 of the California Existing Building Code.
2.
Stationary battery storage arrays located in intermodal shipping containers complying with Chapter 12 of the California Fire Code.
3.
Intermodal shipping containers that are listed as equipment complying with the standard for equipment, such as air chillers, engine generators, modular data centers, and other similar equipment.
4.
Intermodal shipping containers housing or supporting experimental equipment are exempt from the requirements of Section 3115, provided they comply with all of the following:
4.1.
Such units will be single stand-alone units supported at grade level and used only for occupancies as specified under Risk Category I in Table 1604.5.
4.2.
Such units are located a minimum of 8 feet (2438 mm) from adjacent structures, and are not connected to a fuel gas system or fuel gas utility.
4.3.
In hurricane-prone regions and flood hazard areas, such units are designed in accordance with the applicable provisions of Chapter 16.
5.
[HCD] Shipping containers constructed or converted off-site that meet the definition of Factory-built Housing in Health and Safety Code Section 19971 or Commercial Modular(s) as defined in Health and Safety Code Section 18001.8 shall be approved by the Department of Housing and Community Development.
6.
Single-unit stand-alone intermodal shipping containers used as temporary storage or construction trailer on active construction sites. Construction support facilities for uses and activities not directly associated with the actual processes of construction, including but not limited to, offices, meeting rooms, plan rooms, other administrative or support functions shall not be exempt from Section 3115.
3115.2 Construction documents. The construction documents shall contain information to verify the dimensions and establish the physical properties of the steel components and wood floor components of the intermodal shipping container, in addition to the information required by Sections 107 and 1603.
3115.3 Intermodal shipping container information. Intermodal shipping containers shall bear an existing data plate containing the following information as required by ISO 6346 and verified by an approved agency. A report of the verification process and findings shall be provided to the building owner.
1.
Manufacturer's name or identification number.
2.
Date manufactured.
3.
Safety approval number.
4.
Identification number.
5.
Maximum operating gross mass or weight (kg) (lbs).
6.
Allowable stacking load for 1.8G (kg) (lbs).
7.
Transverse racking test force (Newtons).
8.
Valid maintenance examination date.
Where approved by the building official, the markings and existing data plate are permitted to be removed from the intermodal shipping containers before they are repurposed for use as buildings or structures or as part of buildings or structures.
3115.4 Protection against decay and termites. Wood structural floors of intermodal shipping containers shall be protected from decay and termites in accordance with the applicable provisions of Section 2304.12.1.1.
3115.5 Under-floor ventilation. The space between the bottom of the floor joists and the earth under any intermodal shipping container, except spaces occupied by basements and cellars, shall be provided with ventilation in accordance with Section 1202.4.
3115.6 Roof assemblies. Intermodal shipping container roof assemblies shall comply with the applicable requirements of Chapter 15.
Exception: Single-unit, stand-alone intermodal shipping containers not attached to, or stacked vertically over, other intermodal shipping containers, buildings or structures.
3115.7 Joints and voids. Joints and voids that create concealed spaces between intermodal shipping containers, that are connected or stacked, at fire-resistance-rated walls, floor or floor/ceiling assemblies and roofs or roof/ceiling assemblies shall be protected by an approved fire-resistant joint system in accordance with Section 715.
3115.8 Structural. Intermodal shipping containers that conform to ISO 1496-1 and are repurposed for use as buildings or structures, or as a part of buildings or structures, shall be designed in accordance with Chapter 16 and this section.
3115.8.1 Foundations and supports. Intermodal shipping containers repurposed for use as a permanent building or structure shall be supported on foundations or other supporting structures designed and constructed in accordance with Chapters 16 through 23.
3115.8.1.1 Anchorage. Intermodal shipping containers shall be anchored to foundations or other supporting structures as necessary to provide a continuous load path for all applicable design and environmental loads in accordance with Chapter 16.
3115.8.1.2 Stacking. Intermodal shipping containers used to support stacked units shall comply with Section 3115.8.4.
3115.8.2 Welds. The strength of new welds and connections shall be no less than the strength provided by the original connections. All new welds and connections shall be designed and constructed in accordance with Chapters 16, 17 and 22.
3115.8.3 Structural design. The structural design of the intermodal shipping containers repurposed for use as a building or structure, or as part of a building or structure, shall comply with Section 3115.8.4 or 3115.8.5.
3115.8.4 Detailed structural design procedure. A structural analysis meeting the requirements of this section shall be provided to the building official to demonstrate the structural adequacy of the intermodal shipping containers.
Exception: Structures using an intermodal shipping containers designed in accordance with Section 3115.8.5.
3115.8.4.1 Material properties. Structural material properties for existing intermodal shipping container steel components shall be established by Section 2202.
3115.8.4.2 Seismic design parameters. The seismic force-resisting system shall be designed and detailed in accordance with ASCE 7 and one of the following:
1.
Where all or portions of the profiled steel panel elements are considered to be the seismic force-resisting system, design and detailing shall be in accordance with AISI S100 and ASCE 7, Table 12.2-1 requirements for steel systems not specifically detailed for seismic resistance, excluding cantilevered column systems.
2.
Where all or portions of the profiled steel panel elements are not considered to be part of the seismic force-resisting system, an independent seismic force-resisting system shall be selected, designed and detailed in accordance with ASCE 7, Table 12.2-1, or
3.
Where all or portions of the profiled steel panel elements are retained and integrated into a seismic force-resisting system other than as permitted by Section 3115.8.4.2 Item 1, seismic design parameters shall be developed from testing and analysis in accordance with Section 104.11 and ASCE 7, Section 12.2.1.1 or 12.2.1.2.
3115.8.4.3 Allowable shear value. The allowable shear values for the profiled steel panel side walls and end walls shall be determined in accordance with the design approach selected in Section 3115.8.4.2. Where penetrations are made in the side walls or end walls designated as part of the lateral force-resisting system, the penetrations shall be substantiated by rational analysis.
3115.8.5 Simplified structural design procedure of single-unit containers. Single-unit intermodal shipping containers conforming to the limitations of Section 3115.8.5.1 shall be permitted to be designed in accordance with Sections 3115.8.5.2 and 3115.8.5.3.
3115.8.5.1 Limitations. Use of Section 3115.8.5 is subject to all the following limitations:
1.
The intermodal shipping container shall be a single-unit, stand-alone unit supported on a foundation and shall not be in contact with or supporting any other shipping container or other structure.
2.
The intermodal shipping container's top and bottom rails, corner castings, and columns or any portion thereof shall not be notched, cut, or removed in any manner.
3.
The intermodal shipping container shall be erected in a level and horizontal position with the floor located at the bottom.
4.
The intermodal shipping container shall be located in Seismic Design Category A, B, C and D.
3115.8.5.2 Simplified structural design assumptions. Where permitted by Section 3115.8.5.1, single-unit stand-alone, intermodal shipping containers shall be designed using the following assumptions for the profiled steel panel side walls and end walls:
1.
The appropriate detailing requirements contained in Chapters 16 through 23.
2.
Response modification coefficient, R = 2.
3.
Over strength factor, O0 = 2.5.
4.
Deflection amplification factor, Cd = 2.
5.
Limits on structural height, hn = 9.5 feet (2900 mm).
3115.8.5.3 Allowable shear value. The allowable shear values for the profiled steel panel side walls (longitudinal) and end walls (transverse) for wind design and seismic design using the coefficients of Section 3115.8.5.2 shall be in accordance with Table 3115.8.5.3, provided that all of the following conditions are met:
1.
The total linear length of all openings in any individual side walls or end walls shall be limited to not more than 50 percent of the length of that side walls or end walls, as shown in Figure 3115.8.5.3(1).
2.
Any full height wall length, or portion thereof, less than 4 feet (305 mm) long shall not be considered as a portion of the lateral force-resisting system, as shown in Figure 3115.8.5.3(2).
3.
All side walls or end walls used as part of the lateral force-resisting system shall have an existing or new boundary element on all sides to form a continuous load path, or paths, with adequate strength and stiffness to transfer all forces from the point of application to the final point of resistance, as shown in Figure 3115.8.5.3(3). The existing door interlocking mechanism shall not be considered as a component of the required load path.
4.
Where openings are made in container walls, floors or roofs, for doors, windows and other openings:
4.1.
The opening shall be framed with steel elements that are designed in accordance with Chapters 16 and 22.
4.2.
The cross section and material grade of any new steel element shall be equal to or greater than the steel element removed.
5.
A maximum of one penetration not greater than a 6-inch (152 mm) diameter hole for conduits, pipes, tubes or vents, or not greater than 16 square inches (10,322 mm2) for electrical boxes, is permitted for each individual 8 feet (2,438 mm) length of lateral force-resisting wall. Penetrations located in walls that are not part of the wall lateral force resisting system shall not be limited in size or quantity. Existing intermodal shipping container's vents shall not be considered a penetration, as shown in Figure 3115.8.5.3(4).
6.
6. End wall door or doors designated as part of the lateral force-resisting system shall be intermittently welded closed around the full perimeters of the door panels.
TABLE 3115.8.5.3
ALLOWABLE SHEAR VALUES FOR PROFILED STEEL PANEL
SIDE WALLS AND END WALLS FOR WIND OR SEISMIC LOADING
CONTAINER DESIGNATION b
CONTAINER DIMENSION
(Nominal Length)
CONTAINER DIMENSION
(Nominal Height)
ALLOWABLE SHEAR VALUES
(PLF) a,c
Side Wall
End Wall
1EEE
45 feet (13.7 M)
9.5 feet (2896 mm)
75
843
1EE
8.6 feet (2591 mm)
1AAA
40 feet (12.2 M)
9.5 feet (2896 mm)
84
1AA
8.5 feet (2592 mm)
1A
8.0 feet (2438 mm)
1AX
> 8.0 feet (2483 mm)
1BBB
30 feet (9.1 M)
9.5 feet (2896 mm)
112
1BB
8.5 feet (2591 mm)
1B
8.0 feet (2438 mm)
1BX
> 8.0 feet (2438 mm)
1CC
20 feet (9.1 M)
8.5 feet (2591 mm)
168
1C
8.0 feet (2438 mm)
1CX
> 8.0 feet (2438 mm)
a.
The allowable shear values for the side walls and end walls of the intermodal shipping containers are derived from ISO 1496-1 and reduced by a factor of safety of 5.
b.
Container designation type is derived from ISO 668.
c.
Limitations of Sections 3115.8.5.1 and 3115.8.5.3 shall apply.
-Image-6.tif
FIGURE 3115.8.5.3(1)
Bracing Unit Distribution – Maximum Linear Length
-Image-7.tif
FIGURE 3115.8.5.3(2)
Bracing Unit Distribution – Minimum Linear Length
-Image-8.tif
FIGURE 3115.8.5.3(3)
Bracing Unit Distribution – Boundary Elements
-Image-9.tif
FIGURE 3115.8.5.3(4)
Bracing Unit Distribution – Penetrating Limitations
(Added by Ord. No. 2623CCS § 4, adopted 10/22/19; amended by Ord. No. 2727CCS § 4, adopted 10/25/22)