Within the boundaries of the La Habra Boulevard specific plan, the following standards of development, as specified below shall apply:
A. Building Heights.
1. On all parcels with a commercial designation, building heights shall not exceed four stories or fifty feet.
2. On all parcels with a residential designation, building heights shall not exceed two and one-half stories or thirty-five feet.
3. No penthouses or roof structures for the housing of elevators, stairways, tanks, ventilating fans or similar equipment, towers, steeples or other structures shall exceed the height limit provided in this chapter. Radio and television masts, flagpoles, chimneys and smokestacks may extend not more than thirty feet above the height limit provided in this chapter; provided, however, that the same may be safely erected and maintained at such height in view of the surrounding conditions and circumstances.
B. Front Setbacks.
1. There shall be a front building setback of not less than ten feet on all land uses within the plan area designated for commercial uses. Such area shall be landscaped. Such landscaping may be a combination of hardscape and softscape (plants) with at least twenty-five percent of the area devoted to softscape.
2. For residential uses the front setback shall be twenty feet for low-density development and fifteen feet for medium- and high-density development.
3. Cornices, canopies or awnings, eaves, balconies, landings, window boxes or other similar architectural features, not providing additional floor space within the building, may extend into the required front setback area no more than thirty-six inches. Additional encroachment of architectural features may be allowed as approved by the planning commission.
4. Patios provided for uses within areas designated for residential use as private yard area shall not encroach into the setback area.
5. No accessory structure may encroach into any setback area.
C. Side Setbacks.
1. For all side yards along a street frontage there shall be a minimum of a ten-foot setback. Encroachments shall be allowed as described in subsection
B of this section.
2. Side setbacks for commercial buildings are not required, except when such building is located on a corner lot or when it is adjacent to any site designated residential.
3. Whenever an interior side lot line of a commercial or multiple family residential use abuts any portion of a single-unit residential use there shall be provided a setback of not less than ten feet, such area shall be landscaped. For multi-unit residential uses such spaces may be used as private or common yard area.
4. For all uses encroachments are permitted as identified in subsection (B)(3) of this section.
5. For multi-unit development the second floor shall be set back fifteen feet. The roof platform created by the difference between the first and second floor may be used for any use consistent with all the other development standards for the plan area.
6. No accessory structure may encroach into any setback area.
D. Rear Setbacks.
1. There shall be a minimum rear setback requirement along the rear property line of all sites designated for commercial uses of not less than twenty feet.
2. There shall be a minimum rear setback requirement along the rear property line of all sites designated for low-density residential uses of not less than twenty-five feet.
3. There shall be a minimum rear setback requirement along the rear property line of all sites designated for multi-unit residential consistent with the requirements of subsection
C of this section.
4. No accessory structure may encroach into any setback area.
E. Area Requirements. For all sites located in the plan area the minimum standards apply.
1. A minimum lot size for new commercial development shall be five thousand square feet. Minimum lot frontage shall be fifty feet.
2. A minimum parcel size of twenty-four thousand square feet shall be required for new high-density multiple family residential developments. Minimum lot frontage shall be sixty feet.
3. A minimum parcel size of fifteen thousand square feet shall be required for new medium-density multiple family residential developments. Minimum lot frontage shall be sixty feet.
4. Exception. These standards shall not apply to the upgrading, remodeling or overall enhancement or improvement of any existing structure provided that the floor area of such building is not increased more than twenty percent and further provided that there is no decrease in available on-site parking.
5. A minimum lot size of five thousand feet shall be required for all low-density residential uses. Minimum lot frontage shall be fifty feet.
6. Each lot designated for medium-density residential use shall have a minimum of three thousand one hundred feet per dwelling unit.
7. Each lot designated for high-density residential use shall have a minimum of one thousand nine hundred feet per dwelling unit.
8. Maximum land coverage (building footprint) for all multi-unit development shall not exceed forty percent.
9. A minimum floor area of one thousand square feet shall be provided for all single-unit residential dwellings.
10. A minimum dwelling unit size exclusive of garages, carports, balconies, patios, terraces and open porches shall be provided for all multi-unit residential dwellings. The minimum sizes shall be as provided in the following table.
MINIMUM UNIT SIZE |
|---|
Unit Type | Minimum Square Feet |
|---|
Bachelor unit | 480 |
One bedroom | 700 |
Two bedroom | 900 |
Over two bedrooms | 900 + 150 for each additional bedroom |
F. Usable Yard Area.
1. For all commercial uses: none.
2. For all residential uses:
a. Minimum Area Per Parcel. No parcel used for residential development shall have less than one thousand square feet of usable yard area. Usable yard area must have a minimum dimension of fifteen feet. Exception: up to fifty percent of the required area may be twelve feet.
b. Minimum Area Per Dwelling Unit. The minimum required usable yard area shall not be less than two hundred and fifty square feet for each dwelling unit, either as a private usable open space or a combination of private and common open space with at least thirty percent of the units having private open space.
c. Private Usable Yard Area.
i. The required usable yard area when located on open ground, utilized as patios, terraces, atriums, or surfaces of courts shall have a minimum dimension of eight feet and a minimum area of ninety-six square feet.
ii. The required usable yard area when located on balconies, porches or decks shall have a minimum dimension of seven feet and a minimum area of seventy square feet.
d. Common Usable Yard Area.
i. The remaining required usable open space shall be part of the common open space and shall not have any dimension less than fifteen feet and shall not be less than four hundred square feet in area.
ii. All common yard area shall be conveniently located and readily accessible from all dwellings, shall be screened from adjacent streets and shall be landscaped with lawns, trees, shrubs and other permanently maintained plant materials when not used as swimming pools, game courts or other similar recreational facilities.
e. Description.
i. The usable yard area required by this chapter shall not be used for parking, driveways, and automobile turning areas or assessory buildings. The maximum gradient shall be less than five percent.
ii. Such usable yard area shall not be located within a required front yard or a side yard abutting a street, or a required rear yard abutting a street.
G. Parking and Loading—General Regulations, Design Standards, Spaces Required, and Landscaping/Screening. See Chapter
18.14, Off-Street Parking Requirements.
(Ord. 1719 § 1, 2010; Ord. 1748 § 3, 2013; Ord. 1853, 12/18/2023)