The following definitions shall apply:
"Change in operations"shall mean any change in the ownership, food types or operational procedures that have the potential to increase by 25% the amount of fats, oils or grease used or generated by food preparation.
"Fat, oil and grease" ("FOG")shall mean any substance such as a vegetable or animal product that is used in, or is a by-product of, the cooking or food preparation process, and that turns or may turn viscous or solidifies with a change in temperature or other conditions.
"Food facility"as defined in California Uniform Retail Food Facilities Law (CURFFL) Section 113785, shall mean any commercial entity within the city, operating in a permanently constructed structure such as a room, building or place, or portion thereof, maintained, used or operated for the purpose of storing, preparing, serving or manufacturing, packaging or otherwise handling food for sale to other entities or for consumption by the public, its members or employees and which has any process or equipment that uses or produces FOG, or grease vapors, steam, fumes, smoke or odors that are required to be removed by a Type I or Type II hood, as defined in CURFFL, Section 113785.
"Food grinder"shall mean any device installed in the plumbing or sewage system for the purpose of grinding food waste or food preparation by-products for the purpose of disposing it in the sanitary sewer system.
"Grease control device"shall mean any grease interceptor, grease trap or other mechanism or equipment, which attaches to wastewater plumbing fixtures and lines, the purpose of which is to trap/collect FOG prior to it being discharged into the sanitary sewer system. There are two primary types of grease control devices:
(1) A "grease interceptor"is a two- or three-compartment device that is generally required to be located, according to the Uniform Plumbing Code, underground between a food facility and the connection to the sanitary sewer system. These devices can be large (in excess of 750 gallons) and primarily use gravity to separate FOG from the wastewater as it moves from one compartment to the next. These devices must be cleaned, maintained and have the FOG removed and disposed of in a proper manner on a regular interval to be effective. Interceptors shall be structurally intact, including acceptable internal plumbing, manhole inspection covers, baffles between chambers and a structure not compromised by intruding tree roots, etc.
(2) A "grease trap"is a device much smaller than a grease interceptor and services up to a maximum of four individual fixtures. Grease traps need to be emptied more often than grease interceptors to be effective due to their small size. Grease traps have limited effect and should only be used in those cases where the use of a grease interceptor is determined to be impossible or impracticable.
"Grease disposal mitigation fee"shall mean a fee charged to an owner/operator of a food facility or multiple dwelling unit when there are physical limitations to the property that make the installation of the usual and customary grease interceptor for the food facility under consideration, impossible or impracticable.
"Impossibility/impracticability"shall mean, in addition to that which is physically or legally impossible, that which is so difficult to accomplish because of excessive or unreasonable cost. The fact that grease interceptors are expensive or the fact that excavation of paved surfaces may be required will not alone cause impracticability.
"Limited food preparation establishments"shall mean establishments engaged only in reheating, hot holding or assembly of ready to eat food products. It does not include any operation that changes the form, flavor or consistency of food. For purposes of this chapter, a limited food preparation establishment is not considered to be a food facility.
"Multiple dwelling unit"shall mean a building designed and used by three or more families or similar groups of persons living independently of each other which has a common sewer or sewer connection to the city's sewer main.
"Remodeling"shall mean a physical change to a food facility that requires a permit, or involves any one or more combination of the following: (1) under-slab plumbing in the food processing area, (2) a 20% increase in the net public seating area, (3) a 20% increase in the size of the kitchen area, or (4) any change in the size or type of food preparation equipment.
"Sewer lateral"shall mean a building sewer (sanitary) as defined in the Uniform Plumbing Code and as further defined in this code.
"SSO"shall mean a sewage system overflow.
(Ord. 1354 § 1, 2004)