Section 302 is amended to read as follows:
302.1 Electrical. Electrical requirements for aquatic facilities shall be in accordance with the California Electrical Code.
Exception: Internal wiring for portable residential spas and portable residential exercise spas.
302.2 Water Service and drainage. Piping and fittings used for water service, makeup and drainage piping for pools and spas shall comply with the California Plumbing Code. Fittings shall be approved for installation with the piping installed.
302.3 Pipe, fittings and components. Pipe, fittings and components shall be listed and labeled in accordance with NSF 50 or NSF 14. Plastic jets, fittings and outlets used in public spas shall be listed and labeled in accordance with NSF 50.
Exceptions: |
1. | Portable residential spas and portable residential exercise spas listed and labeled in accordance with UL 1563 or CSA C22.2 No 218.1. |
2. | Onground storage pools supplied by the pool manufacturer as a kit that includes all pipe, fittings and components. |
302.4 Concealed piping inspection. Piping, including process piping, that is installed in trenches, shall be inspected prior to backfilling.
302.5 Backflow protection. Water supplies for pools and spas shall be protected against backflow in accordance with the California Plumbing Code.
302.6 Wastewater discharge. Where wastewater from pools or spas, such as backwash water from filters and water from deck drains discharge to a building drainage system, the connection shall be through an airgap in accordance with the California Plumbing Code.
302.7 Tests. Tests on water piping systems constructed of plastic piping shall not use compressed air for the test.
302.8 Maintenance. Pools and spas shall be maintained in a clean and sanitary condition, and in good repair.
302.8.1 Manuals. An operating and maintenance manual in accordance with industry-accepted standards shall be provided for each piece of equipment requiring maintenance.
(Ord. 2197 § 2, 2019; Ord. 2241 § 2, 2022; Ord. 2299, 10/21/2025)