Table 17.14.020(A) - Minimum Setbacks for Residential Zones
| |||||
---|---|---|---|---|---|
Zone Requirement
|
SF
|
AE2
|
R-1
|
R-21
|
R-31
|
Front Yard
|
20 ft.
|
See Formula 1
|
See Formula 2
| ||
Side Yard Interior Side (Interior & Corner
Lot)
|
5 ft.
|
Living area walls3 and bedroom walls4: 8 ft.
Secondary walls5: 5 ft.
|
Living area walls3 and bedroom walls4: 8 ft.
Secondary walls5: 5 ft.
| ||
Side Yard Street Side (Corner Lot)
|
10 ft.
|
See Formula 3
|
See Formula 4
| ||
Garage opening onto side street
|
20 ft.
|
10 ft.
|
20 ft.
|
N/A
|
N/A
|
Rear Yard (Interior Lot, Corner Lot, Reverse Corner
Lot)
|
15 ft.
|
Lots with lot depth of < 150 ft: 15 ft. or 15% of lot depth,
whichever is greater
|
15 ft.
|
Living area walls3 and bedroom walls4: 8 ft.
| |
Lots with lot depth ≥ 150 ft.: 20% of lot depth
|
Secondary walls5: 5 ft.
| ||||
Rear Yard (Through Lots):
|
20 ft. or See Formula 1: whichever is greater
|
20 ft.
| |||
Lots uniform along block
|
5 ft.13
|
20 ft.
|
5 ft.13
|
20 ft. or See Formula 1: whichever is greater
|
20 ft.
|
Lots not uniform along block
|
20 ft. 13 & 14
| ||||
Swimming Pool
|
5 ft. from side/rear property line and exterior finish of house
or structure
| ||||
Alleys
|
5 ft.
|
N/A
|
5 ft.
|
25 ft. from opposite side of alley
|
Table 17.14.020(B) Height, Area & Mass for Residential Zones
| |||||
---|---|---|---|---|---|
Zone Requirement
|
SF
|
AE1 & 2
|
R-1
|
R-21
|
R-31
|
Maximum Building Height
|
2 stories / 30 ft., whichever is less
|
2 ½ stories / 35 ft., whichever is less
| |||
Minimum Lot Area
|
7,000 sq. ft.
|
10,000 sq. ft.
|
5,000 sq. ft.
|
6,000 sq. ft.
|
6,000 sq. ft.
|
Minimum Living Area
|
950 sq. ft. Exclusive of porches and garages
|
Single Unit
Parcels < 19,000 sq. ft.: 1,500 sq. ft.
Parcels ≥ 19,000 sq. ft.: 10 % of parcel area up to 2,500
sq. ft.
Multiple Unit
Additional residential units: 1,250 sq. ft.
|
Same as SF
|
Single: 500 sq. ft.
1-Bedroom: 700 sq. ft.
2-Bedroom: 900 sq. ft.
3-Bedroom: 1100 sq. ft.
More than 3 bedrooms increase unit size by 150 sq. ft. for each
additional bedroom
|
Same as R-2
|
Maximum Lot Coverage
|
45 % of lot area15
|
40% of lot area, excludes unpaved animal enclosures
|
45% of lot area15
|
N/A
| |
Maximum Floor Area Ratio
|
N/A
|
50% of lot area, excludes unpaved animal enclosures
|
N/A
|
2/3 Rule7
| |
Maximum Dwelling Unit Density
|
1 unit per lot20
|
1 unit per 9,900 sq. ft. of net land area20
|
1 unit per 5,000 sq. ft. of net land area20
|
8-13 units / acre; 1 unit / 3,350 sq. ft. of net land area20
|
14-22 units / acre; 1 unit / 1,980 sq. ft. of net land area20
|
Maximum Concrete Area Within Required Front Yard Area
|
40%
|
N/A
|
Table 17.14.020(C) Parking & Driveways for Residential Zones
| |||||
---|---|---|---|---|---|
Zone Requirement
|
SF
|
AE1 & 2
|
R-1
|
R-21
|
R-31
|
Parking Requirement
|
2-car garage: 20 ft. x 20 ft. clear and unobstructed floor space
|
Single Unit
Same as SF
Multiple Unit
2-car garage plus
1 parking space per bedroom after the first two
bedrooms
1 open parking space per unit for visitors' use17
| |||
Driveway Width
|
Min. 10 ft. wide
|
Single Unit
Same as SF
Multiple Unit
Min. 12 ft. if wall exposures are < 150 ft. from
street
Min. 20 ft. if wall exposures are < 300 ft. from
a street for 10 or fewer units.18
Min. 26 ft. with turnaround if wall exposures are
≥ 300 ft. from a street or if more than 10 units
|
Table 17.14.020(D) Building Variation & Separation for Residential
Zones
| |||||
---|---|---|---|---|---|
Zone Requirement
|
SF
|
AE1 & 2
|
R-1
|
R-21
|
R-31
|
Minimum Building Wall Variation
|
N/A
|
Single Story
3 ft. per 60 ft. for a min. of 15 ft. or to the end of building
if < than 15 ft.
Two Story
3 ft. per 40 ft. for a min. of 15 ft. or to the end of building
if < than 15 ft.
|
N/A
|
Buildings 80 ft. in length shall have variations in wall set
back of at least 4 ft. for each 80 ft. of building length
| |
Minimum Building Separation19
|
N/A
|
Single Unit
N/A
Multiple-Unit
15 ft.
|
N/A
|
Residential buildings or building wings of same structure: 15
ft. Non-Residential portions of residential buildings: 10 ft.
|
Table 17.14.020(E) Open Space & Landscaping for Residential
Zones
| |||||
---|---|---|---|---|---|
Zone Requirement
|
SF
|
AE1 & 2
|
R-1
|
R-21
|
R-31
|
Minimum Private Open Space
|
N/A
|
Multiple-Unit 200 sq. ft. on ground floor
with minimum 10 ft. dimensions; Must be enclosed by 5 ft. high decorative
wall.
|
N/A
|
150 sq. ft. with minimum dimension of 8 ft.8
For 10 dwellings or less 20% of lot area is required for the
private open space.9
| |
Minimum Private Group Space
|
N/A
|
11 or more units:
Single: 300 sq. ft. /unit
1-Bedroom: 400 sq. ft. /unit
2-bedroom: 550 sq. ft. /unit
3-Bedroom: 700 sq. ft. /unit
≥4-bedroom: 100 sq. ft./unit10
|
11 or more units:
25% of total land area.10
| ||
Minimum Landscaping
|
All required front-yard and street-facing side-yard setbacks,
excluding driveways and walkways, shall be landscaped and maintained
|
All required front-yard and street-facing side-yard setbacks,
excluding driveways and walkways, shall be landscaped and maintained
Multiple-Unit: Two 48-in. box trees per
unit and two 5-gal. plants per dwelling unit
|
All required front-yard and street-facing sideyard setbacks,
excluding driveways and walkways, shall be landscaped and maintained
|
All required front-yard and street-facing side-yard setbacks,
excluding driveways and walkways, shall be landscaped and maintained.
50% of group open space shall be landscaped with natural plant
material
½ of this amount shall be lawn or turf
Remaining space shall be planted in ground cover, trees, shrubs
& provided with an irrigation system.
One 48-in. box tree per unit.
| |
Maximum Paved Recreational Facilities
|
N/A
|
Maximum 40% of group open space may be paved in surface including
a swimming pool, walks, patio, terraces, courts & fountains
Recreational/communal buildings may not cover more than 10%
of this area
|
KEY:
| |||
---|---|---|---|
Formula 1
|
=
|
16 ft. + 2 ft. (number of stories) + 1 ft. building
wall (length)
10
| |
Formula 2
|
=
|
6 ft. + 2 ft. (number of stories) + 1 ft. building
wall (length)
20
| |
Formula 3
|
=
|
6 ft. + 2 ft. (number of stories) + 1 ft. building
wall (length)
10
| |
Formula 4
|
=
|
4 ft. + 2 ft. (number of stories) + 1 ft. building
wall (length)
20
|
NOTES:
| |
---|---|
1.
|
If developed with single unit, R1 standards will apply.
|
2.
|
If lot is less than 8,000 square feet R1 standards will apply.
|
3.
|
Living area wall: A wall contains the principle windows of a
habitable room, such as living rooms, family rooms, dining rooms and
the like.
|
4.
|
Bedroom wall: A wall that contains the principle windows of
bedrooms.
|
5.
|
Secondary wall: A wall that contains the windows of kitchens
or bathrooms as well as those walls that have no windows.
|
6.
|
Reserved.
|
7.
|
The "2/3" rule requires the top story to be not more than two-thirds the size in total floor area of the bottom story. Deviation from this rule is permitted if the residential structure incorporates "desirable architectural elements" and satisfies the process outlined in for R-2 zone or BMC Section 17.32.100 for R-3 zone.
|
8.
|
Private area must be equipped with one weather-proof electrical
outlet.
|
9.
|
Front yard set back to be included in 20% for R-2 zone or 25%
for R-3 zone lot area calculations but private yard area shall not
be placed in front yard set back.
|
10.
|
Development of 11 dwelling units or more: a maximum of 75% of
the total required group open space may be allocated as additional
private open space purposes upon approval of the Planning Director.
|
11.
|
All walkway ramps and steps must be lighted.
|
12.
|
Enclosure shall be constructed of concrete block or equivalent
and enhanced with stucco or other architectural material to match
building.
|
13.
|
In SF and R-1 only: Through lots shall record a restrictive
covenant relinquishing their right to access the rear of their property
from the right-of-way adjacent to their rear property line lot to
the satisfaction of the Director of Community Development.
|
14.
|
In SF and R-1 only: The Planning Director may approve through
lots with a rear yard setback that is the average setback on the street
but in no case shall the rear yard setback be less than 15 feet.
|
15.
|
Lot coverage shall be computed by utilizing the actual roof
area, not including eaves, of all residential and accessory buildings.
|
16.
|
Screening methods shall be architecturally compatible with the
main building.
|
17.
|
A parking space is considered to be a minimum size of nine feet
by 20 feet. All required parking for each single family residence
must be adjacent to that structure. Where the required parking cannot
be reasonably complied with adjacent to the residence on lots of peculiar
shape or location, the regulations herein specified may be modified
upon application to the Planning Commission.
|
18.
|
Minimum 20 foot driveway may be reduced to 15 feet if: sufficient
fire flow exists and units more than 150 feet from the street are
equipped with a domestic sprinkler system(s). Encroachment into the
15 foot access requirement is only allowed if an existing front structure
protrudes into the 15 foot access and cannot be reasonably moved or
remodeled. However, in no case shall the encroachment reduce access
to less than 12 feet wide.
|
19.
|
These provisions shall not be deemed to supersede any Building
Code requirements for separation of buildings.
|
20.
|
Pursuant to State law, accessory dwelling units do not increase
the allowable density of residential uses.
|
Table 17.14.020(F) Detached Accessory Structures for Residential
Zones
| |||||
---|---|---|---|---|---|
Zone Requirements
|
SF
|
AE
|
R-1
|
R-2
|
R-3
|
Location
|
Completely to the rear of the main building
50 ft. from front property line
|
Completely to the rear of the main building
60 ft. from front property line
|
Same as SF Zone
|
Anywhere after the front or side street yard setback
| |
Minimum Side Yard Setback: Interior Side
|
None1
|
3 ft.; If wall higher than 10 ft. above grade, provide min.
setback of 5 ft.
|
Same as SF Zone
|
If less than 50 ft. from front property line: Living area walls3 and bedroom walls4: 8
ft. or secondary walls5: 5 ft.
If completely at rear of building and located 50 ft. from front
property line: None1
| |
Minimum Side Yard Setback: Street Side
|
20 ft. for garage or carport that opens onto side street
or
10 ft. if no garage or carport opening onto side street
|
If less than 50ft. from front property line:
Living area walls3 and bedroom walls4: 8 ft. or secondary walls5: 5 ft.
If completely at rear of building and located 50ft. from front
property line: N/A
| |||
Minimum Rear Yard Setback: Interior/Corner Lots
|
None1
|
3 ft.
Detached buildings with a wall higher than 10 ft. above grade
shall provide minimum setback of 5 ft.
|
Same as SF Zone
|
If less than 50 ft. from front property line: Living area walls3 and bedroom walls4: 8
ft. or secondary walls5: 5 ft.
If completely at rear of building and located 50 ft. from front
property line: None1
| |
Setback from Alley
|
Uniform development: 5 ft.6
Inconsistent development: 20 ft.6&7
|
25 ft. from opposite side of alley
|
Same as SF Zone
|
Same as AE Zone
| |
Maximum Height
|
1 story/18 ft.
|
1 story or 20 ft. whichever is less
|
Not to exceed 1 story
|
15 ft.
| |
Minimum Building Separation1
|
N/A
|
7 ft.
|
N/A
|
7 ft. from main building; 3 ft. from other accessory buildings
| |
Maximum Size2
|
N/A
|
1,000 sq. ft. provided it does not exceed 10% of the lot size
and it does not exceed the size of the existing primary dwelling8&9
|
N/A
|
600 sq. ft.
|
NOTES:
| |
---|---|
1.
|
Must conform with fire resistance requirements and drainage
on the subject property.
|
2.
|
Garages are limited to 1,000 sq. ft. and must conform to lot
coverage and floor area as listed on underlying zone.
|
3.
|
Living area wall: A wall contains the principle windows of a
habitable room, such as living rooms, family rooms, dining rooms and
the like.
|
4.
|
Bedroom wall: A wall that contains the principle windows of
bedrooms.
|
5.
|
Secondary wall: A wall contains the windows of kitchens or bathrooms
as well as those walls that have no windows.
|
6.
|
Through lots shall record a restrictive covenant relinquishing
their right to access the rear of their property from the right-of-way
adjacent to their rear property line lot to the satisfaction of the
Director of Community Development.
|
7.
|
The Planning Director may approve through lots with a rear yard
setback that is the average setback on the street but in no case shall
the rear yard setback be less than 15 feet.
|
8.
|
An accessory structure may exceed 1,000 sq. ft. if a Conditional
Use Permit is obtained.
|
9.
|
A restrictive covenant must be obtained stipulating that the
accessory building will not be utilized as a rental unit.
|
Table 17.14.020(G) Projections into Yards for Residential Zones
| |||||
---|---|---|---|---|---|
Zone Requirements
|
SF
|
AE
|
R-1
|
R-2
|
R-3
|
Porches/ Platforms/ Landing Places
| |||||
Height
|
May not extend above the level of the first floor
| ||||
Extension into front or side yard
|
Maximum projection of 6 ft. with maximum 30 inch high openwork
railing
| ||||
Architectural Features1
| |||||
Side Yard / Front Yard
|
No more than 4 in. for each one foot of the width of such side
yard, but not more than 30 ft. projection
| ||||
Fire Escapes
| |||||
Front Yard / Side Yard
|
Max 4 ft. projection
|
NOTE:
|
1.
|
Also includes cornices, eaves, belt courses, sills, buttresses,
fireplaces, windows, fully screened mechanical equipment, or other
similar features.
|
Table 17.14.020(H) Fences, Hedges and Walls for Residential
Zones
| |||||
---|---|---|---|---|---|
Zone Requirements
|
SF1
|
AE1
|
R-11
|
R-21
|
R-31
|
Fence/ Wall Materials
| |||||
Chain Link
|
Prohibited in front and street side yard setbacks
| ||||
Wood, Plastic, Vinyl, Metal, Aluminum, Brick or other Stone
|
Allowed
| ||||
Fence/ Hedge/ Wall Height Based on Location
| |||||
Within Front Yard Setback Area
|
42 inches; 48 inches shall be allowed if the material above
24 inches is at least 50% transparent
| ||||
Outside of Front Yard Setback Area
|
6 feet
|
NOTE:
| |
---|---|
1.
|
Permanent fences must comply with BMC Section 17.72.060(C)—(N).
|
Table 17.14.030 Development Standards for C-G and M-1
| ||
---|---|---|
Zone Requirement
|
C-G
|
M-1
|
Max. Building Height
|
No limitation
|
12 stories or 150 feet in height, whichever is lesser
|
Min. Front Yard Setback for Interior Lots, Corner Lots,
Reversed Corner Lots, and Through Lots
|
10 feet from front property line or ultimate right-of-way, whichever
is greater1&2
| |
Min. Side and Rear Yard
|
No setback is required3
| |
Min. Area Requirement
|
15,000 sq. ft., with a min. frontage of 100 feet on each public
street4&9
| |
Min. Parking Requirements
|
1 parking space for every 300 sq. ft. of building areas, exclusive
of driveway, maneuvering and access area5
|
Warehouse use (excluding self-storage facilities as defined in Chapter 17.08): 1 parking space for each 1,000 sq. ft. of floor space or fraction thereof
|
For additional parking requirements for specified uses, see Chapter 17.88 of this Code
|
All other uses: 1.5 parking spaces for each 2 permanent employees
or 1 parking space for each 500 sq. ft. of floor space or fraction
thereof, whichever is greater
All uses: 1 parking space for each vehicle operated by any concern
utilizing the use
| |
Min. Loading
|
For hospitals & institutions:
3,000-20,000 = 1 loading space
20,000-50,000 = 2 loading spaces
Over 50,000 = 3 loading spaces
|
For hospitals & institutions:
Same as C-G Zone
|
For hotels and office buildings:
3,500-50,000 = 1 loading space
Over 50,000 = 2 loading spaces
|
For hotels and office buildings:
Same as C-G Zone
| |
For all other uses:
3,000-15,000 sq. ft. = 1 loading space
15,100-45,000 sq. ft. = 2 loading spaces
45,100-75,000 = 3 loading spaces
Over 75,000 sq. ft. = 4 loading spaces
|
For all other uses:
33,500-40,000 sq. ft. = 1 loading space
40,100-80,000 sq. ft. = 2 loading spaces
Over 80,000 = 3 loading spaces
| |
Fences and Walls6
|
If property abuts a residential district either on a side or
rear yard: Min. 6-foot high and max. 8-foot high of solid masonry
construction is required, provided no wall shall exceed 42 inches
in height where it is in the front yard area of an abutting residential
use or district
Chain link fences are prohibited in front yard and street side
yard setbacks
| |
Trash Facilities
|
Required for each lot, designed to meet the following minimum:
The size of the trash facility is subject to approval by the
planner and must be enclosed by a 5-foot high solid masonry, brick
or concrete wall with solid decorative gates of the same height and
architecturally consistent trellis cover7
Must be located where there is adequate vehicular access, subject
to approval by the planner
Must be maintained in a closed manner at all times to prohibit
unauthorized access and to prevent visibility from public rights-of-way
or adjacent property
| |
Mechanical Equipment
|
Must be enclosed within a permanent sound proofed enclosure
subject to the approval of the building inspector
Must be maintained in a clean and proper condition to prevent
a collection of litter and filth and to avoid the emission of unnecessary
noise, dust or fumes
| |
Lighting
|
All outdoor lighting shall be located and shielded so as to
prevent spill of light onto adjacent lots and streets
| |
Min. Landscaping8
|
5% of the parking area with a minimum 10-foot wide landscaped
planter located adjacent to all rights-of-way
For each 1,000 sq. ft. of floor area provide one 48-inch box
tree and five 5-gallon plants
Planting beds must be a minimum of 6 feet in width to be distributed
throughout the parking area and must be bordered by a minimum 6-inch
high concrete curb except where decorative walls are provided
No automobile space may incorporate the required planter within
its dimension
Earth mounding shall be used when required by the Planner
For specific installation, maintenance and irrigation details, see Section 17.44.070.
|
NOTES:
| |
---|---|
1.
|
No building nor structure, nor enlargement thereof shall hereby
be erected unless the required front yard setback is provided.
|
2.
|
Through lots shall maintain the required front yard setback
on both abutting streets.
|
3.
|
Any structure to be constructed within three feet of a side
or rear property line shall be constructed of concrete block, concrete
tilt up, or equivalent material. Permanent wall, color, texture, and/or
relief shall be cast into concrete and shall not be painted.
|
4.
|
A separate lot or parcel of record as of September 3, 1957,
which lot or parcel may be occupied or utilized as having the minimum
required area. A separate lot or parcel created prior to June 22,
1987, pursuant to applicable Municipal Code provisions, which lot
or parcel may be occupied or utilized as having the minimum required
area.
|
5.
|
If required parking is not located on the same lot as the structure
for which it provides the parking, the parking must be located within
500 feet of the building.
|
6.
|
Any permanent fence is subject to approval by the City as permitted in Section 17.72.060. Notwithstanding any other provisions of this title, all existing uses, buildings, and structures in the C-G Zone which do not conform to this Code shall provide said perimeter wall at the time any permit is issued for physical alterations which also exceed the adopted valuation threshold for disabled access.
|
7.
|
All trash enclosures shall meet applicable Fire Code provisions,
including, but not limited to fire-rated construction, and where deemed
appropriate by the Building Official, shall incorporate the use of
an overhead sprinkler system.
|
8.
|
Landscape and irrigation plans shall be submitted to the Department
of Planning and shall show the type, quantity, location, and size
of all plants and irrigation equipment. Plants shall be selected appropriately
based upon their adaptability to the climatic, geologic, and topographical
conditions of the site and the type shall be approved by the Planning
Director. Protection and preservation of native species and creation
of hydrozones are encouraged. Compliance to the landscape provisions
contained herein is required for all properties located within the
C-G Zone in conjunction with any alteration or modification of the
property except where the alteration and modification does not result
in an expansion of more than 50% of the gross floor area of all structures
on the property.
|
9.
|
Projects to be developed with private streets which are constructed
and maintained to City standards with CC&Rs, that establish mutual
easements, covenants and restrictions upon the property and each of
the parcels for vehicular and pedestrian access, subject to approval
by the City Council.
|