In all areas of special flood hazard, the following provisions are required:
A.
New construction, substantial improvements, and repair to structures that have sustained substantial damage shall be anchored to prevent flotation, collapse or lateral movement of the structure, resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy.
B.
New construction, substantial improvements, and repair to structures that have sustained substantial damage shall be constructed with materials and utility equipment resistant to flood damage and conform to the provisions of FEMA Technical Bulletin 2, Flood Damage-Resistant Material Requirements. This includes, but is not limited to, flooring, interior and exterior walls, wall coverings and other materials installed below the base flood elevation plus one foot.
C.
New construction or substantial improvements shall be constructed by methods and practices that minimize flood damage.
D.
The bottom of all electrical, heating, plumbing, ventilation and air-conditioning equipment, appliances, fixtures and components, HVAC duct work and duct systems, and any other utility service equipment, facilities, machinery, or connections servicing a structure shall be elevated at least one foot above the base flood elevation (BFE). This includes, but is not limited to, furnaces, oil or propane tanks, air conditioners, heat pumps, hot water heaters, ventilation duct work, washer and dryer hookups, electrical junction boxes, and circuit breaker boxes. Connections or other equipment that must be located below the BFE plus one foot elevation are permitted only when no other elevation alternative is available and provided they are designed and installed to prevent water from entering or accumulating within the components and to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of the base flood event. Electrical wiring systems that must be located below the BFE plus one foot shall conform to the standards for wet locations.
E.
New and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system.
F.
New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of floodwaters into the system and discharges from the system into floodwaters.
G.
On-site waste disposal systems shall be located and constructed to avoid impairment to them or contamination from them during flooding.
H.
Manufactured homes.
(1)
All manufactured (mobile) homes to be newly placed, undergoing a substantial improvement or repaired as a result of substantial damage in areas of special flood hazard, shall be elevated so that the bottom of the frame is located one foot above the base flood elevation. The manufactured home must also meet all the construction standards as per § 211-17. The foundation and anchorage of manufactured homes to be located in floodways shall be designed and constructed in accordance with ASCE 24. This includes areas of special flood hazard located outside a manufactured home park or subdivision, in a new manufactured home park or subdivision, in an existing manufactured home park or subdivision, in an expansion to an existing manufactured home park or subdivision, or on a site in an existing manufactured home park in which a manufactured home has incurred substantial damage as a result of a flood;
(2)
They shall be placed on a permanent foundation which itself is securely anchored and to which the structure is securely anchored so that it will resist flotation, lateral movement, and hydrostatic and hydrodynamic pressures. Anchoring may include, but not be limited to, the use of over-the-top or frame ties to ground anchors;
(3)
In any portion of a watercourse which is altered or relocated, the flood-carrying capacity shall be maintained;
(4)
Recreational vehicles placed on sites within areas of special flood hazard shall either be on the site for fewer than 180 consecutive days, and be fully licensed and ready for highway use, or meet all the general standards of § 211-17 and the elevation and anchoring requirement of § 211-17H. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick-disconnect-type utilities and security devices, and has no permanently attached additions; and
(5)
A structure already in compliance with the provisions of this chapter shall not be made noncompliant by any alteration, repair, reconstruction or improvement to the structure.
I.
Underground tanks shall be anchored to prevent flotation, collapse and lateral movement under conditions of the base flood. The bottom of aboveground storage tanks which are located outside or inside of a structure must be elevated one foot above the base flood elevation or shall be securely anchored to prevent flotation, collapse or lateral movement under conditions of the base flood. Where elevated on platforms, the platforms shall be cantilevered from or knee braced to the building or shall be supported on elevated foundations that conform to the standards for the particular flood zone as described in § 211-8. Anchored tanks must have the top of the fill pipe located at least one foot above the BFE and have a screw fill cap that does not allow for the infiltration of floodwater.
J.
New construction, substantial improvements and repair to structures that have sustained substantial damage cannot be constructed or located entirely or partially over water unless they are a functionally dependent use or facility.
K.
If any portion of a structure lies within the area of special flood hazard, the entire structure is considered to be located within the area of special flood hazard and must meet the construction requirements of the flood zone. The structure includes any structurally attached additions, garages, decks, porches, sunrooms, patios or any other structure attached to the main structure.
L.
If a structure lies within two or more flood zones, the construction standards of the most restrictive zone apply to the entire structure (i.e., structure must be built to the highest base flood elevation). The structure includes any structurally attached additions, garages, decks, porches, patios, sunrooms, or any other structure attached to the main structure.
M.
Compensatory storage. The water holding capacity of the floodplain, except those areas which are tidally influenced, shall not be reduced. Any reduction caused by filling, new construction or substantial improvements involving an increase in footprint to the structure, shall be compensated for by deepening and/or widening of the floodplain. Storage shall be provided on-site, unless easements have been gained from adjacent property owners; it shall be provided within the same hydraulic reach and a volume not previously used for flood storage; it shall be hydraulically comparable and incrementally equal to the theoretical volume of floodwater at each elevation, up to and including the 100-year flood elevation, which would be displaced by the proposed project. Such compensatory volume shall have an unrestricted hydraulic connection to the same waterway or water body. Compensatory storage can be provided off-site if approved by the municipality.
N.
Equal conveyance. Within the floodplain, except those areas which are tidally influenced, as designated on the Flood Insurance Rate Map (FIRM) for the community, encroachments resulting from filling, new construction or substantial improvements involving an increase in footprint of the structure, are prohibited unless the applicant provides certification by a registered professional engineer demonstrating, with supporting hydrologic and hydraulic analyses performed in accordance with standard engineering practice, that such encroachments shall not result in any (0.00 feet) increase in flood levels (base flood elevation). Work within the floodplain and the land adjacent to the floodplain, including work to provide compensatory storage shall not be constructed in such a way so as to cause an increase in flood stage or flood velocity.