[Added 3-30-2016 ATM
by Art. 41]
4.4.1 Purpose. Lexington seeks to have a socially and economically diverse community, both over the whole of the community and within its neighborhoods. In support of that fundamental social goal, a basic housing goal is to provide housing opportunities supportive of the population diversity we seek. The Town encourages small- and medium-sized housing stock, in the interest of providing diverse housing sizes throughout the Town, §
4.4 limits the massing of buildings, which may impact owners of abutting properties, the streetscape, landscape, and the character of the neighborhood and Town.
4.4.2 Maximum Allowable Residential Gross Floor Area Tables. The total
gross floor area of all buildings on a lot containing a one-family
or two-family dwelling may not exceed the amount listed in Table 4.4.2.2
based on lot area, except that:
[Amended 4-24-2023 ATM by Art. 40]
a. Buildings for which a building permit application has been submitted before January 1, 2024, may be extended, altered, reconstructed or structurally changed so long as the total gross floor does not exceed that in Table 4.4.2.1 below based on lot area. For the purposes of this §
4.4.2, extension, alteration, reconstruction, and structural change shall not include any construction which involves demolition of more than 50% of the primary building's shell exclusive of demolition of a single-story attached garage. For purposes of calculating the percentages of any demolition under this subsection, all demolition shall be taken into account which commenced, or could have commenced, pursuant to an issued permit within two years prior to the date of any request for any permit to construct, reconstruct, alter, add, extend or otherwise structurally change any structure.
b. For the purposes of §
6.12.3.7(a), Table 4.4.2.1 shall be used to determine the gross floor area permitted based on a proof plan.
Table 4.4.2.1
|
---|
Lot Area
(in square feet)
|
Maximum Gross Floor Area
(in square feet)
|
---|
0 to 5,000
|
0.8 * lot area
|
5,000 to 7,500
|
4,000 + 0.55 * (lot area - 5,000)
|
7,500 to 10,000
|
5,375 + 0.23 * (lot area - 7,500)
|
10,000 to 15,000
|
5,950 + 0.2 * (lot area - 10,000)
|
15,000 to 30,000
|
6,950 + 0.16 * (lot area - 15,000)
|
More than 30,000
|
9,350 + 0.16 * (lot area - 30,000)
|
Table 4.4.2.2
|
---|
Lot Area
(in square feet)
|
Maximum Gross Floor Area
(in square feet)
|
---|
0 to 5,000
|
0.76* Lot Area
|
5,000 to 7,500
|
3,800 + 0.42 * (lot area - 5,000)
|
7,500 to 10,000
|
4,850 + 0.12 * (lot area - 7,500)
|
10,000 to 15,000
|
5,150 + 0.11 * (lot area - 10,000)
|
15,000 to 30,000
|
5,700 + 0.1 * (lot area - 15,000)
|
More than 30,000
|
7,200 + 0.1 * (lot area - 30,000)
|
4.4.3 Special Permit. Pursuant to §
9.4, the SPGA may grant a special permit for a building to exceed the maximum gross floor area otherwise allowed by §
4.4 provided that the SPGA finds that the desired relief may be granted without substantial detriment to the neighborhood and without derogating from the intent and purpose of this bylaw including Town policy documents that define housing goals. In addition to the criteria in §
9.4.2, the SPGA shall find that:
a. The project is compatible with the scale of the neighborhood;
b. The massing of the project does not adversely impact the solar access
of adjoining lots;
c. Noise generated by fixed plant equipment, such as, but not limited
to, air conditioners, pumps, fans, and furnaces, does not adversely
impact adjoining lots; and
d. The project design addresses specific neighborhood and Town concerns.
[Added 10-14-2020 STM by Art. 9]
4.5.1 Purpose. The purposes of this section are to preserve and protect
groundwater; to maintain and enhance the public safety, environment,
health, and general welfare by establishing minimum requirements;
and to establish procedures to control the adverse effects of building
basement floors nearer than two feet from the estimated seasonal high
groundwater table (ESHGWT), including basement flooding, pumping and
discharge of groundwater to neighboring properties, discharging groundwater
to the public way, and illicit connections to the Town's sewer and
stormwater connections.
4.5.2 Definitions.
ESTIMATED SEASONAL HIGH GROUNDWATER TABLE (ESHGWT)
The estimated highest level to a zone of saturation in the
soil in most years under normal wet season, as determined by a registered
professional engineer, a qualified soil scientist or licensed soil
evaluator.
4.5.3 Applicability. The requirement of this §
4.5 shall apply to:
2. Additions to an existing dwelling that increases a building footprint
by more than 1,000 square feet.
4.5.4 Conditions and Requirements. The vertical distance between the finished basement floor of any dwelling shall not be less than two feet above the ESHGWT. Permission for a vertical distance less than two feet above the ESHGWT may be granted if the applicant provides sufficient evidence that a proposed lesser vertical distance will not impact the structure being proposed in a manner contrary to the purposes of this §
4.5, any other structures or constructed facilities, or the functions of the natural groundwater system (such as base flow maintenance) and if all of the following conditions are met:
1. Detailed engineering plans, certified by a registered professional
engineer showing a foundation and perimeter drain management system
and roof stormwater management system(s) that will mitigate and control
groundwater discharge and stormwater runoff, are provided;
2. The provided foundation and perimeter drain discharge management
system and roof stormwater management system plans have been reviewed
by the Building, Conservation, Health and Engineering Departments
and comments adequately addressed;
3. Roof drains and downspouts connect to a stormwater management system
designed by a registered professional engineer; and
4. The applicant has agreed to pay the fee for consulting services to
perform engineering review pursuant to the provisions of MGL c. 44,
§ 53G.