Table 4.1 Table of General Bulk Regulations
| |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Building Massing
| |||||||||||||
Minimum lot width and frontage
|
200 feet
|
100 feet
|
n/a
|
120 feet
|
50 feet
|
40 feet
|
75 feet
|
40 feet
|
100 feet
|
100 feet
|
150 feet
|
175 feet
|
n/a
|
Minimum lot area
|
65,000 square feet1
|
15,000 square feet
|
n/a
|
n/a
|
5,000 square feet
|
4,000 square feet
|
9,375 square feet
|
4,000 square feet
|
20,000 square feet
|
20,000 square feet
|
43,450 square feet
|
43,560 square feet
|
n/a
|
Maximum building coverage
|
15% of lot area
|
30% Accessory bldg. not more than 3% of lot area
|
3%
|
15%
|
40% Accessory bldg. not more than 15% of lot area
|
50% Accessory bldg. not more than 15% of lot area
|
30% Accessory bldg. not more than 5% of lot area
|
70% Accessory bldg. not more than 50% of rear yard
|
33.3% Accessory bldg. not more than 15% of lot area
|
33.3% Accessory bldg. not more than 15% of lot area
|
25%
|
30% (Main building, min. floor area 6,000 square feet)
|
n/a
|
Maximum lot coverage (total impervious)
|
n/a
|
n/a
|
6%
|
20%
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
Setbacks - Principal Bldg.
| |||||||||||||
Minimum front setback - principal bldg.
|
75 feet
|
30 feet
|
n/a
|
48 feet
|
10 feet4
|
10 feet4
|
20 feet4
|
60 feet on Amity Rd, 10 feet on other roadways
|
60 feet on Amity Rd, 10 feet on other roadways
|
75 feet
|
75 feet
|
n/a
| |
Minimum front setback - secondary bldg.
|
n/a
|
n/a
|
n/a
|
48 feet
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
Minimum side setback
|
25 feet
|
15 feet
|
n/a
|
20 feet
|
6 feet4
|
4 feet4
|
10 feet4
|
3 feet
|
12 feet
|
12 feet
|
30 feet
|
10 feet
|
n/a
|
Minimum rear setback
|
25 feet
|
25 feet
|
n/a
|
40 feet
|
Min. depth 20% of lot, but need not exceed 20 feet4
|
Min. depth 20% of lot, but need not exceed 20 feet4
|
25 feet4
|
Min. depth 10% of lot, but need not exceed 20 feet
|
20 feet
|
20 feet
|
30 feet
|
25 feet
|
n/a
|
Frontage buildout
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
n/a
|
80% Min
|
n/a
|
Setbacks - accessory building(s). No accessory building
in any district shall be in a front yard. No accessory building shall
be in any side yard nearer to the side yard lot line than the distance
listed below
| |||||||||||||
Front setback
|
75 feet
|
30 feet
|
n/a
|
20 feet min and bldg. setback
|
10 feet5
|
10 feet5
|
20 feet5
|
60 feet on Amity Rd., 10 feet on other roadways
|
60 feet on Amity Rd., 10 feet on other roadways
|
60 feet on Amity Rd., 10 feet on other roadways
|
n/a
|
75 feet
|
n/a
|
Side setback
|
15 feet
|
15 feet
|
n/a
|
3 feet
|
5 feet5
|
5 feet5
|
10 feet5
|
3 feet
|
5 feet
|
5 feet
|
5 feet
|
10 feet
|
n/a
|
Rear setback
|
15 feet
|
15 feet
|
n/a
|
3 feet
|
5 feet5
|
5 feet5
|
25 feet5
|
3 feet
|
5 feet
|
5 feet
|
5 feet
|
25 feet
|
n/a
|
Building Height - Number of Stories
| |||||||||||||
Maximum stories excluding cellar and basement
|
2 1/2
|
2 1/2
|
n/a
|
2
|
2 1/2
|
2 1/2
|
2 1/2
|
3
|
3
|
3
|
3
|
2
|
n/a
|
Residential Density
| |||||||||||||
Families per building
|
16
|
16
|
n/a
|
n/a
|
26
|
26
|
16
|
n/a
|
n/a
|
8 per acre (must be accessory to legal non- residential use
650 square feet/du max)
|
n/a
|
n/a
|
n/a
|
Reference: 1 acre = 43,560 square feet
| |
---|---|
1
|
All new lots proposed in a Residence A District that are: (1)
created after November 9, 2001, and (2) located 50% or more within
a drinking water supply watershed mapped or designated by the South-Central
Connecticut Regional Water Authority, shall contain a minimum of two
acres of buildable lot area. Buildable lot area is defined as that
contiguous portion of a lot exclusive of and undivided by any areas
of wetland soils and watercourse as defined in Section 22a-38 of the
Connecticut General Statutes. All new lots must comply with this requirement
whether or not they are part of a subdivision.
|
All new lots proposed in a Residence A District created after
November 9, 2001, whether or not in a subdivision, shall be of such
shape that a square with 150 feet on each side will fit on the lot
within the setback boundaries.
| |
2
|
See Section 4.B Specific to Dev 1.
|
3
|
See Section 4.B Specific to Dev 2.
|
4
|
Corresponds to setback diagrams for primary buildings on bulk
diagram sheets for T3-C, T3-D, T3-BB.
|
5
|
Corresponds to setback diagrams for accessory buildings on bulk
diagram sheets for T3-C, T3-D, T3-BB.
|
6
|
See § 495-15LL.
|
Transect Table T3-C
| ||
---|---|---|
BUILDING HEIGHT
| ||
Principal Building
|
35' - 0"max
| |
Outbuilding
|
20'-0" max.
| |
BUILDING LOCATION: SEE TABLE 4.1
| ||
SETBACKS - PRINCIPAL BUILDING
| ||
(g.1) Front Setback Principal
|
10 feet min.
| |
(g.2) Front Setback Secondary
|
n/a
| |
(g.3) Side Setback
|
6 feet min.
| |
(g.4) Rear Setback
|
20% of depth of lot*
| |
Frontage Buildout
|
n/a
| |
SETBACKS - OUTBUILDING
| ||
(h.1) Front Setback
|
10'- 0" min.
| |
(h.2) Side Setback
|
5 feet
| |
(h.3) Rear Setback*
|
5 feet min
| |
*But need not exceed 20'- 0"
|
| ||
---|---|---|
BUILDING HEIGHT
| ||
Principal Building
|
35'-0" max.
| |
Outbuilding
|
35'-0" max.
| |
BUILDING LOCATION: SEE TABLE 4.1
| ||
SETBACKS - PRINCIPAL BUILDING
| ||
(g.1) Front Setback Principal
|
10 feet min
| |
(g.2) Front Setback Secondary
|
n/a
| |
(g.3) Side Setback
|
4 feet min.
| |
(g.4) Rear Setback
|
20% of depth of lot*
| |
Frontage Buildout
|
n/a
| |
SETBACKS - OUTBUILDING
| ||
(h.1) Front Setback
|
10' feet min.
| |
(h.2) Side Setback
|
5 feet
| |
(h.3) Rear Setback*
|
5 feet min
| |
* But need not exceed 20'-0".
|
Table 4.3 Design Speed Table for Private Roadways
| ||||||
---|---|---|---|---|---|---|
Design Speed
(mph)
|
Travel Lane Width
(feet)
|
T1
|
T2
|
T3
|
Dev
|
P
|
Below 20
|
8
|
*
|
*
|
*
|
*
|
*
|
20-25
|
9
|
*
|
*
|
*
|
*
|
*
|
25-35
|
10
|
*
|
*
|
*
|
*
|
*
|
25-35
|
11
|
*
|
*
| |||
Above 35
|
12
|
*
|
*
| |||
Design Speed
|
Parking Lane Width
| |||||
20-25
|
(Angle) 18
|
*
| ||||
25-35
|
(Parallel) 7
|
*
|
*
| |||
25-35
|
(Parallel) 8
|
*
|
*
|
*
| ||
Above 35
|
(Parallel)9
|
*
| ||||
Design Speed
|
Parking Lane Width
| |||||
20-25
|
5-10
|
*
|
*
|
*
| ||
25-35
|
10-15
|
*
|
*
|
*
|
*
|
*
|
25-35
|
15-20
|
*
|
*
|
*
|
*
|
*
|
Above 35
|
20-30
|
*
|
*
|
*
|
Table 4.4. Sign Allowed in all Zones Without a Permit
| |||
---|---|---|---|
Type of Sign
|
Maximum Number of Signs
|
Maximum Size/Area
| |
1.
|
Traffic control signs required or approved by the Woodbridge
Traffic Authority or by the State of Connecticut.
|
n/a
|
n/a
|
2.
|
Names of buildings, dates of erection, monumental citations,
commemorative tablets, and the like, when carved into or made of stone,
wood, bronze, aluminum, or other permanent materials, and made an
integral part of the construction.
|
n/a
|
n/a
|
3.
|
Signs of a noncommercial nature and in the public interest,
erected by, or on the order of a public official in the performance
of a public duty, such as safety signs, memorial plaques, or signs
of a historical interest.
|
n/a
|
n/a
|
4.
|
Temporary political signs
|
n/a
|
n/a
|
5.
|
Real estate signs advertising the sale, rental, or lease of
premises, provided that the maximum height of said sign does not exceed
5 feet.
|
1 sign per premises.
|
a. In any residential district, not more than 4 square feet
on each of 2 sides; and
b. In any business or development district, not more than 25
square feet on each of 2 sides.
|
6.
|
Signs for professionals, including but not limited to carpenters,
painters, roofers, etc., on the premises where the work is being performed,
provided that:
a. No such sign exceeds 4 feet in height; and
b. Such sign is removed promptly upon completion of the work.
|
1 sign per premises.
|
a. In any residential district, not more than 4 square feet
on each of 2 sides; and
b. In any business or development district, not more than 25
square feet on each of 2 sides.
|
7.
|
Temporary street signs within subdivisions prior to road acceptance.
|
n/a
| |
8.
|
Signs no closer than 75 feet apart along the property line,
bearing notification of restriction on trespassing, hunting, fishing,
or dumping upon the premises on which it is located.
|
n/a
|
Not more than 1 square foot per side
|
9.
|
Permanent signs erected and maintained by a church or civic
or fraternal organization exempt from federal income tax under the
provisions of Section 501(C) of the Internal Revenue Code for the
purpose of notifying the public of the presence in the Town of such
church or organization.
|
n/a
|
n/a
|
10.
|
Temporary or permanent signs erected and maintained by the Town
or any agency thereof pursuant to the performance of a government
function.
|
n/a
|
n/a
|
Table 4.5 Signs Permitted in A, B, and T3 Zones
| |||
---|---|---|---|
Type of sign
|
Maximum Number of Signs
|
Type of Sign
| |
1.
|
A sign bearing the name and/or street address, and/or permitted
residence office of the resident. (No permit required.)
|
1 for each permitted use or dwelling
|
2 square feet in total area.
|
2.
|
A garage or tag sale sign, advertising a sale to be held within
3 days following the erection of such sign, of personal property and
effects which are owned by the owner or tenant of the premises and
used for residential or domestic household purposes. Such sign shall
be removed upon completion of the advertised event. (No permit required.)
|
Table 4.6 Signs Permitted for Nonresidential Uses in A, B, and
T3 Zones
| |||
---|---|---|---|
Type of Sign
|
Maximum Number of Signs
|
Maximum Size/Area
| |
1.
|
1 or more wall signs provided that the total area of all wall
signs does not exceed 20 square feet. (Zoning permit required.)
|
1 sign per street frontage
|
20 square feet in total area.
|
2.
|
1 or more wall signs when the total area of all wall signs exceeds
20 square feet. (Special exception required.)
|
1 sign per street frontage.
|
1 sign per street frontage.
|
3.
|
A freestanding sign erected or placed perpendicular or parallel
to the public street or highway to which the building or structure
fronts or abuts provided that the sign does not exceed 5 feet in height
or 40 square feet in area. (Special exception required.)
|
1 freestanding sign per street frontage.
|
20 square feet in total area per side.
|
4.
|
A sign for a nonconforming use. (Special exception required.)
|
As determined by the Commission.
|
As determined by the Commission.
|
5.
|
A temporary A-framed sandwich board sign solely for use by the
business establishments established by special exception or as an
existing nonconforming use in accordance with Section 5.1.1[1] of this chapter.
|
1 temporary sandwich sign for advertising use per business or
occupant which can be used up to 6 different times in 1 calendar year
(January-December) for a cumulative total of no more than 6 weeks
during a calendar year. (Zoning Permit required.)
|
6 square feet in total area on each of 2 sides.
|
Table 4.7 Signs Permitted in Dev 1, Dev 2, BI, GB, GBA, and
P Nonresidential Zones
| |||
---|---|---|---|
Type of sign
|
Maximum Number of Signs
|
Maximum Size/Area
| |
1.
|
1 wall sign displaying the name and/or street address of the
owner or occupant of the premises and/or the activity conducted thereon.
(Zoning permit required.)
|
1 sign per tenant, except as may be allowed by Section 4.5.1.3.[2]
|
1 square foot per linear foot of facade of the tenant space
but not more than 25 square feet or not more than 1 square foot per
1,000 square feet of gross floor area, whichever is greater.
|
2.
|
1 projecting sign displaying the name of the owner or occupant
of the premises and/or the activity conducted thereon provided there
is at least 14 feet of clearance under the sign for vehicular traffic
and at least 7 feet of clearance under the sign otherwise. (Zoning
permit required.)
|
1 sign per tenant.
|
12 inches by 18 inches in total area on each of 2 sides.
|
3.
|
1 additional wall sign or projecting sign displaying the name
of the owner or occupant of the premises. (Special exception required.)
|
1 additional sign.
| |
4.
|
An entrance identification sign for a rear entrance into a building
or tenant space from a parking area. (Zoning permit required.)
|
1 sign
|
4 square feet in area.
|
5.
|
Sign(s) identifying store hours and nonadvertising notices.
(No permit required.)
|
n/a
|
1 square foot in total area per tenant space.
|
6.
|
For a residence in a nonresidential zone, a sign bearing the
name and/or street address; and/or permitted residence office of the
resident. (No permit required.)
|
1 for each permitted use or dwelling
|
2 square feet in total area.
|
7.
|
Permanent window sign(s) on store windows for a permitted use
provided that a permanent window sign permit has been obtained. (Zoning
permit required.)
|
2 window surfaces
|
25% of the window area where it is located. Note: Signage for
larger window area may be granted by the Commission by special exception
for good cause shown.
|
8.
|
A freestanding sign erected or placed on the premises provided
that the maximum height of such sign does not exceed 10 feet. The
height of the sign must be proportional to the setback of the sign
from the property line. (Special exception required.)
|
1 freestanding sign per premises
|
24 square feet in total area on each of 2 sides.
|
9.
|
Professional tenant directory sign, identifying tenants, shall
be allowed. The sign shall be located away from the road frontage
of the property. (Special exception required.)
|
1 freestanding sign
|
No portion of the sign shall be more than 6 feet above the average
level of the rough grade within a radius of 10 feet. Each tenant shall
be allowed a two-square-foot sign on the directory sign, displaying
only the tenant's name. In addition to the names, the directory
may contain a layout of the center which shall not exceed 6 square
feet.
|
10.
|
A temporary banner sign announcing special events directly related
to the activity or use conducted within the premises, provided that
no more than 4 permits per tenant for such special events signs shall
be issued in any 1 calendar year. (Zoning permit required.)
|
1 sign per business or occupant for up to 2 weeks, but no more
than 1 sign per property at any 1 time.
|
12 square feet in total area.
|
11.
|
Temporary window sign for a permitted conforming use (Zoning
permit required.), provided that: a) Such sign will not be displayed
for more than 15 consecutive days; b) If such use has only window
and such window contains a permanent window sign, then the temporary
sign shall not exceed 15% of the total window surface.
|
1 temporary sign.
|
25% of the window surface where it is located.
|
12.
|
Barber pole sign. (Zoning permit required)
|
1 per hair cutting establishment in addition to other permitted
signs.
|
A barber pole may not exceed 3 feet in height, excluding the
supporting structure.
|
13.
|
Awning signs, provided that the area of the sign shall be computed
as part of the total sign area for the subject building and lot. (Zoning
permit required)
| ||
14.
|
Temporary A-frame sandwich-board signs (Zoning permit required.)
|
1 temporary sandwich sign. For advertising use per business
or occupant which can be used up to 6 different times in 1 calendar
year (January - December) for a cumulative total of no more than 6
weeks during a calendar year.
|
6 square feet in total area on each of 2 sides.
|
15.
|
A directory sign on a Class A road established in Figure 2.2
of this chapter, for businesses not on a Class A road. Proof must
be provided that such a sign is in the public welfare and that the
applicant has the legal right to erect such a sign. (Special exception
required.)
|
1 sign.
|
Table 4.8 Signs Permitted in T1 and T2 Zones
| |||
---|---|---|---|
Type of Sign
|
Maximum Number of Signs
|
Maximum Size/Area
| |
1.
|
Name plate or sign for permitted uses giving only the name of
the occupant or use of the premises.
|
1 sign or name plate.
|
Sign shall not exceed a total surface area of 1 1/2 square
feet
|
2.
|
Bulletin boards and signs on the premises of churches, schools,
and similar nonprofit institutions.
|
1 sign.
|
Signs shall not exceed 16 square feet in total area and may
be part of the architecture of the building.
|
3.
|
Signs advertising the use of a premises for special exception
uses.
|
1 sign
|
Signs shall not exceed 16 square feet in total area
|
4.
|
Freestanding signs.
|
1 sign.
|
Signs shall be no more than 6 feet in height and shall comply with § 495-38 and applicable setback regulations.
|