Table 26-13-010-1: Minimum Lighting Intensity
| |
---|---|
Location
|
Minimum Intensity
|
Exterior building entrances
|
4 foot candles
|
Parking areas and pedestrian walkways
|
1 foot candle
|
Elevators, stairwells, and corridors
|
0.5 foot candle
|
Table 17.12.020-1: Fences and Walls in Residential Districts
| |
---|---|
Location
|
Maximum Height
|
Within required front yard setback
|
42 inches[1]
|
Within interior side or rear yard setback
|
7 feet[2]
|
Within street side setback
|
42 inches[3]
|
Within a controlled area vision triangle
|
30 inches[4]
|
Outside of a required setback
|
7 feet[2]
|
Notes:
| |
[1]
|
Height can be increased above 42 inches to a maximum height
of 7 feet if constructed outside of the required front yard or at
the point equal to the building's front façade, whichever is
less.
|
[2]
|
Height can be increased above 7 feet with a building permit.
|
[3]
|
Fences above 42 inches and to a maximum height of 7 feet without
a building permit must be placed at least 5 feet behind property line,
outside of any public right-of-way easement, and must be landscaped
in this setback area.
|
[4]
|
See Figure 17.12.020-1 and Section 17.12.020(B)
|
Table 17.12.070-1
Minimum Vehicular Parking Requirements
| |
---|---|
Land Use
|
Vehicular Parking Requirements
|
Public Assembly
| |
Commercial recreational facility—indoor
|
|
Arcade or amusement center
|
1 space for each 300 square feet of gross floor area
|
Bowling alley
|
2 spaces for each lane
|
Skating rink
|
1 space for each 300 square feet of rink area, plus 1 space
for each 10 fixed seats
|
Theater
|
1 space for each 5 fixed seats, or 1 space for each 100 square
feet of gross floor area if no fixed seats; exceptions may be provided
for theaters with more than 500 seats, subject to a use permit
|
Commercial recreational facility—outdoor
|
Determined by use permit
|
Gym
|
1 space for each 300 square feet of gross floor area
|
Instructional studio
|
1 space for each 300 square feet of gross floor area
|
Library or museum
|
1 space for each 300 square feet of gross floor area
|
Meeting facility
|
1 space for each 5 fixed seats, or 1 space for each 100 square
feet of gross floor area if no fixed seats; plus additional spaces
as required by this section for accessory uses, such as offices
|
Restaurant or café
|
1 space for each 100 square feet of gross floor area
|
School—elementary or middle school
|
3 spaces for each classroom
|
School—high school
|
7 spaces for each classroom
|
Residential
| |
Boardinghouse
|
1 space for each bedroom
|
Caretaker dwelling unit
|
1 space for each dwelling unit
|
Duplex
|
2 spaces for each dwelling unit
|
Emergency shelter
|
1 space per 10 adult beds
|
Family day care, large
|
2 spaces, in addition to those required for the dwelling unit
|
Family day care, small
|
None beyond requirement for dwelling unit
|
Home occupation
|
None beyond requirement for dwelling unit
|
Mobile home park
|
1 space for each dwelling unit, plus 1 guest parking space for
each 4 dwelling units
|
Studio or 1 bedroom
|
1 space for each dwelling unit
|
2 or more bedrooms—projects with fewer than
14 dwelling units per acre
|
2 spaces for each dwelling unit
|
2 or more bedrooms—projects with 14 or more
dwelling units per acre
|
1.5 spaces for each dwelling unit
|
Guest parking for multiple-family dwellings
|
1 space for each 4 dwelling units
|
Residential care facility—6 units or fewer
|
Same as requirements for applicable type of dwelling unit
|
Residential care facility—7 units or more
|
1 space for each 3 beds
|
Second dwelling unit
|
1 space for each dwelling unit
|
Single-family dwelling
|
2 spaces for each dwelling unit
|
Retail
| |
All "retail" uses listed in Ch. 17.28, except the following:
|
1 space for each 300 square feet of gross floor area
|
Alcoholic beverage sales—on-premises consumption
|
1 space for each 100 square feet of gross floor area
|
Automobile sales
|
1 space for each 2,000 square feet of site area
|
Gas station
|
As required for individual accessory uses; minimum of 2 spaces
|
Restaurant or café
|
1 space for each 4 seats, including outdoor seating
|
Mobile home, boat or recreational vehicle sales
|
1 space for each 1,000 square feet of site area
|
Services
| |
All "services" uses listed in Ch. 17.28, except the following:
|
1 space for each 300 square feet of gross floor area
|
Bed and breakfast
|
1 space for each guest room, plus 1 space for any resident manager
|
Car wash
|
2 spaces for each wash bay
|
Hospital
|
1.1 spaces for each bed
|
Hotel or motel
|
1 space for each guest room, plus additional spaces as required
by this section for accessory uses
|
Mortuary
|
1 space for each 6 fixed seats, or 1 space for each 100 square
feet of gross floor area if no fixed seats
|
Personal services
|
1 space for each 200 square feet of gross floor area
|
Manufacturing, Wholesale, Repair and Storage
| |
All "manufacturing, wholesale, repair and storage" uses listed in Ch. 17.28, except the following:
|
1 space for each 1,000 square feet of gross floor area; minimum
of 2 spaces
|
Mini-storage facility
|
1 space for each 3,000 square feet of gross floor area; minimum
of 4 spaces
|
Research laboratories
|
1 space for each 300 square feet of gross floor area
|
Warehousing
|
1 space for each 2,000 square feet of gross floor area used
for storage, plus 1 space for each 300 square feet of other gross
floor area
|
Transportation and Infrastructure
| |
All "transportation and infrastructure" uses listed in Ch. 17.28
|
1 space for each 1,000 square feet of gross floor area; minimum
of 4 spaces
|
Table 17.12.080-1
Loading Space Requirements
| |
---|---|
Land Use
|
Loading Space Requirements
|
Retail or Service
| |
Food and beverage sales—15,000 square feet or more of
gross floor area
|
1 space
|
Shopping center with less than 30,000 square feet of gross floor
area
|
1 space
|
Any use with 30,000 square feet or more of gross floor area
|
1 space, plus additional spaces as required by the applicable
authority
|
Hotels and motels, hospitals and other facilities with temporary
overnight accommodations and 10 or more beds
|
1 space
|
Manufacturing, Wholesale, Repair and Storage Uses
| |
Any use with 10,000 square feet or more of gross floor area
|
1 space
|
Any use with 40,000 square feet or more of gross floor area
|
1 space, plus additional spaces as required by the applicable
authority
|
Utility building or substation
|
1 space
|
Structure
|
Maximum Height
|
---|---|
Accessory structure
|
15′
|
Accessory structure over 15 feet in height
|
25′1
|
Garage with 2nd story dwelling unit
|
25′1
|
|
Floor Area2
|
Detached garage
|
700 sq. ft.3
|
All other accessory structures
|
25% of the floor area of the main structure3
|
1
|
Development review committee approval shall be required pursuant to Section 17.52.020.
|
2
|
For the maximum floor area for a second dwelling unit refer to Section 17.16.010(E).
|
3
|
Development review committee approval shall be required to exceed these limitations pursuant to Section 17.52.020.
|