A manufactured home placed on an individual lot, other then
a lot in an approved manufactured dwelling park, shall conform to
the requirements of the zone in which it is located, applicable state
installation standards, and the following additional provisions:
A. The
manufactured home shall be multi-sectional and enclose a floor space
of not less than 1,000 square feet.
B. The
manufactured home shall be placed on an excavated and/or back-filled
foundation and enclosed by skirting at the perimeter such that the
manufactured home is located at least 16 inches from mainframe to
grade.
C. The
skirting and perimeter foundation of the manufactured home shall consist
of masonry or poured concrete.
D. The
manufactured home shall have a roof with a minimum pitch of 3:12.
The roofing material shall be composition, shake, shingle or tile.
E. The
manufactured home shall have exterior siding material such as horizontal
or vertical wood, vinyl or aluminum lap siding similar to that used
in single-family residences constructed to the Uniform Building Code.
F. The
manufactured home shall not have bare metal siding or roofing.
G. The
manufactured home shall be certified by the manufacturer to have an
exterior thermal envelope meeting performance standards which reduce
levels equivalent to the performance standards required of single-family
dwelling constructed under the State Building Code ORS 455.010.
H. The manufactured home is required to have an attached or detached garage or carport that complies with Chapter
16.180. A building permit for the associated garage or carport must be issued concurrent with the placement permit for the manufactured home.
I. The
manufactured home shall have a permanent porch with a minimum size
of 24 square feet. No temporary steps will be allowed at the time
of occupancy. The Uniform Building Code will determine minimum landing
size.
J. All
porches and decks to be constructed shall be shown on the site/plot
plan.
K. The
manufactured home shall have a meter base and no power pole.
L. The
manufactured home shall utilize at least two of the following design
features:
3. Architectural grade roofing.
5. Window shutters or treatments.
6. Off-sets on building face or roof (minimum 12 inches).
10. Eaves (minimum six inches).
M. All
load-bearing foundations, supports and enclosures shall be installed
in conformance with the Oregon Building Codes Agency regulations and
with the manufacturer's installation specifications. Manufactured
homes must also be provided with a permanent perimeter enclosure.
N. The
manufactured home's wheels, axles and hitch mechanism shall be removed.
The wheels, axles and hitch mechanisms shall not be left under the
manufactured home.
O. If
a manufactured home is removed from its foundation and not replaced
by another manufactured home within 60 days, the owner of the lot
shall immediately thereafter remove the foundation, fill all excavations
and disconnect and secure all utilities.