A manufactured home placed on an individual lot, other then a lot in an approved manufactured dwelling park, shall conform to the requirements of the zone in which it is located, applicable state installation standards, and the following additional provisions:
A. 
The manufactured home shall be multi-sectional and enclose a floor space of not less than 1,000 square feet.
B. 
The manufactured home shall be placed on an excavated and/or back-filled foundation and enclosed by skirting at the perimeter such that the manufactured home is located at least 16 inches from mainframe to grade.
C. 
The skirting and perimeter foundation of the manufactured home shall consist of masonry or poured concrete.
D. 
The manufactured home shall have a roof with a minimum pitch of 3:12. The roofing material shall be composition, shake, shingle or tile.
E. 
The manufactured home shall have exterior siding material such as horizontal or vertical wood, vinyl or aluminum lap siding similar to that used in single-family residences constructed to the Uniform Building Code.
F. 
The manufactured home shall not have bare metal siding or roofing.
G. 
The manufactured home shall be certified by the manufacturer to have an exterior thermal envelope meeting performance standards which reduce levels equivalent to the performance standards required of single-family dwelling constructed under the State Building Code ORS 455.010.
H. 
The manufactured home is required to have an attached or detached garage or carport that complies with Chapter 16.180. A building permit for the associated garage or carport must be issued concurrent with the placement permit for the manufactured home.
I. 
The manufactured home shall have a permanent porch with a minimum size of 24 square feet. No temporary steps will be allowed at the time of occupancy. The Uniform Building Code will determine minimum landing size.
J. 
All porches and decks to be constructed shall be shown on the site/plot plan.
K. 
The manufactured home shall have a meter base and no power pole.
L. 
The manufactured home shall utilize at least two of the following design features:
1. 
Dormer.
2. 
Recessed entries.
3. 
Architectural grade roofing.
4. 
Bay or bow windows.
5. 
Window shutters or treatments.
6. 
Off-sets on building face or roof (minimum 12 inches).
7. 
Gables.
8. 
Covered porch entry.
9. 
Pillars or posts.
10. 
Eaves (minimum six inches).
11. 
4:12 pitch roof.
M. 
All load-bearing foundations, supports and enclosures shall be installed in conformance with the Oregon Building Codes Agency regulations and with the manufacturer's installation specifications. Manufactured homes must also be provided with a permanent perimeter enclosure.
N. 
The manufactured home's wheels, axles and hitch mechanism shall be removed. The wheels, axles and hitch mechanisms shall not be left under the manufactured home.
O. 
If a manufactured home is removed from its foundation and not replaced by another manufactured home within 60 days, the owner of the lot shall immediately thereafter remove the foundation, fill all excavations and disconnect and secure all utilities.