Unless a provision of this article explicitly states otherwise, the following terms and phrases, as used in this article, shall have the meaning hereinafter designated.
An assembly to counteract backpressure or prevent backsiphonage that meets the standards contained in the plumbing code.
A device used to prevent backsiphonage in nonhealth hazard conditions. This device cannot be tested and cannot prevent backpressure backflow.
The flow in the direction opposite to the normal flow or the introduction of any foreign liquids, gases, or substances into the water system of the city's water.
A means of protection against backflow that shall be provided in accordance with the plumbing code.
Any elevation of pressure in the downstream piping system (by any means) above the supply pressure at the point of consideration which would cause, or tend to cause, a reversal of the normal direction of flow and the introduction of fluids, mixtures, or substances from any source other than the intended source.
The flow of water or other liquids, mixtures or substances into the distribution pipes of a potable water supply system from any source other than its intended source caused by a sudden reduction of pressure in the potable water supply system.
Any use other than a single-family residential structure that is less than 5,000 square feet in size. Commercial uses include all nonresidential uses.
A test form that has been logged into a TCEQ-approved record keeping system for which all applicable fees have been paid to the regulatory authority.
Any foreign material, solid or liquid, not common to the potable water supply which makes or may make the water unfit or undesirable for human or animal consumption.
Any connection, physical or otherwise, between a potable water supply system and any plumbing fixture, or any tank, receptacle, equipment or device, through which it may be possible for any nonpotable, used, unclean, polluted and contaminated water, or other substances, to enter into any part of such potable water system under any condition or set of conditions.
Any assembly placed upon any connection, physical or otherwise, between a potable water supply system and any plumbing fixture, or any tank, receptacle, equipment or device, which is designed to prevent nonpotable, used, unclean, polluted, and contaminated water, or other substances, from entering into any part of such potable water system under any condition or set of conditions.
The low or high hazard classification that shall be attached to all actual or potential cross connections.
Health hazard. An actual or potential threat of contamination of a physical or toxic nature to the public potable water system or the consumer's potable water system that would be a danger to health.
High hazard. The classification assigned to an actual or potential cross connection that potentially could allow a substance that may cause illness or death to backflow into the potable water supply.
Low hazard. The classification assigned to an actual or potential cross connection that potentially could allow a substance that may be objectionable but not hazardous to one's health to backflow into the potable water supply.
Plumbing hazard. An internal or plumbing-type cross connection in a consumer's potable water system that may be either a pollution or a contamination-type hazard.
Pollution hazard. An actual or potential threat to the physical properties of the water system or the potability of the public or the consumer's potable water system but which would not constitute a health or system hazard, as defined. Maximum degree of intensity of pollution which the potable water system could be degraded under this definition would cause a nuisance or be aesthetically objectionable or could cause damage to the system or its appurtenances.
System hazard. An actual or potential threat of severe danger to the physical properties of the public or consumer's potable water supply or of a pollution or contamination that would have a detrimental effect on the quality of the potable water in the system.
An assembly composed of a line-size approved double check assembly with a bypass containing a specific water meter and an approved double check valve assembly. The meter shall register accurately for very low rates of flow.
An assembly which consists of two (2) independently acting, approved check valves, including tightly closing resilient seated shutoff valves attached at each end of the assembly and fitted with properly located resilient seated test cocks.
Any operation which may have the potential to introduce contaminants into a potable water system from a mobile source. These include, but are not limited to, carpet-cleaning vehicles, water-hauling vehicles, street-cleaning vehicles, liquid-waste vehicles, power-wash operations and pest-control vehicles.
An assembly which provides protection against backsiphonage, but does not provide adequate protection against backpressure backflow. The assembly is a combination of a single check valve with an AVB and can be used with downstream resilient seated shutoff valves. In addition, the assembly has suction and discharge gate valves and resilient seated test cocks which allow the full testing of the assembly.
Any public or privately owned water system which supplies water for public domestic use. The system will include all services, reservoirs, facilities, and any equipment use in the process of producing, treating, storing, or conveying water for public consumption.
Wastewater, collected and treated at a wastewater treatment plant, which has been treated to a quality that meets or exceeds the requirements of the Texas Commission on Environmental Quality's chapter 210 authorization to the city.
An assembly containing two (2) independently acting approved check valves together with a hydraulically operated, mechanically independent pressure differential relief valve located between the check valves and at the same time below the first check valve. The assembly shall include properly located resilient seated test cocks and a tightly closing resilient seated shutoff valve at the end of the assembly.
An assembly composed of a line-size approved reduced pressure principle assembly with a bypass containing a specific water meter and an approved reduced pressure principle backflow prevention assembly. The meter shall register accurately for very low rates of flow.
Responsible managing employee dwelling.
Responsible managing employee general.
Sprinkler certificate of registration dwelling.
Sprinkler certificate of registration general.
Irrigation not permanently installed underground.