Toilet rooms and bathrooms shall provide privacy and shall not constitute the only passageway
to a hall or other space, or to the exterior. A door and interior
locking device shall be provided for all common or shared bathrooms and toilet rooms in a multiple
dwelling.
Toilet rooms and bathrooms serving hotel units, rooming units or dormitory
units or housekeeping units, shall have access by
traversing not more than one flight of stairs and shall have access
from a common hall or passageway.
Toilet facilities shall have access from within the employees'
working area. The required toilet facilities shall be located not
more than one story above or below the employees' working area and
the path of travel to such facilities shall not exceed a distance
of 500 feet (152 m). Employee facilities shall either be separate
facilities or combined employee and public facilities.
Exception: Facilities that are required for employees
in storage structures or kiosks, which are located in adjacent structures
under the same ownership, lease or control, shall not exceed a travel
distance of 500 feet (152 m) from the employees' regular working area
to the facilities.
In other than dwelling units, every toilet room floor shall be maintained to be a smooth, hard,
nonabsorbent surface to permit such floor to be easily kept in a clean
and sanitary condition.