[Ord. No. 2023-01, 5/1/2023]
The following items shall be included in the SWM site plan as provided in Appendix C, Minor SWM permit Site Design Worksheet:[1]
1.
Project Information.
2.
Date of submission, and the dates of all revisions.
3.
North arrow.
4.
Location of all existing and proposed on-site improvements.
5.
Approximate location of all existing and proposed utilities and utility easements, including, but not limited to, on-lot wastewater facilities, water supply wells, sanitary sewers, water lines, gas lines, and electric lines.
6.
Location and clear identification of the type of proposed permanent SWM facilities.
7.
Proposed limit of disturbance line(s) and disturbed acres.
8.
An erosion and sediment control plan. Note that further review by the county conservation district/reviewing authority may be required per § 28-301.
9.
SWM conservation easements for all physical SWM facilities, conveyance facilities, areas downstream of discharges and spillways, and designated meadows. When present, provisions for permanent access to SWM conservation easements shall also be granted to the Municipality via a note as listed in § 28-402, Subsection 24J, below.
10.
Easements shall be a minimum of 20 feet in width, and must extend at least five feet beyond the edge of any SWM facility.
11.
Where possible, easements should be centered on the facilities within the easement.
13.
Easements shall be identified with metes and bounds. In the case of conveyance facilities such as pipes and swales, and if desired by the applicant, a note as listed in § 28-402, Subsection 24L, below may be added to the plan in lieu of metes and bounds stating that easements are to be located and offset from the center of the installed conveyance facility. Subterranean facilities utilizing this alternative easement identification method shall use metal marking tape, or other methods that provide simple identification from the surface as reviewed and accepted by the Municipal Engineer, in order to mark the location of said facilities; subsurface conveyance facilities shall add the identification method to the note required above, and the identification method shall be added to relevant construction details. The site plan shall also show approximate distances from the property boundaries. The site plan shall be attached and recorded with the O&M agreement.
15.
If stormwater BMP(s) described in Appendix C[2] are proposed, the applicable worksheet(s) from Appendix C shall be submitted with the minor SWM site plan. If a BMP type not described in Appendix C, a SWM report conforming to the requirements of § 28-403 shall be submitted with the minor SWM site plan.
[2]
Editor's Note: Said appendix is included as an attachment to this chapter.
[1]
Editor's Note: Said appendix is included as an attachment to this chapter.