(a) Districts Established.
The following Mixed-Use zone districts are established in this Code, as summarized in Table 21.03-1. When the Code refers to "Mixed-Use" zone districts, these districts are included:
Table 21.03-7: Mixed-Use Zone Districts Summary |
|---|
Legacy Zone Districts | Zone Districts Name | Section |
|---|
R-O: Residential - Office+nB-1: Neighborhood Business | Mixed-Use Neighborhood, MU-1 | |
M-U: Mixed Use C-1: Light Commercial BP: Business Park Mixed-Use MXOC: Mixed-Use Opportunity Corridor | Mixed-Use Light Commercial, MU-2 | |
B-2: Downtown Business | Mixed-Use Downtown, MU-3 | |
C-2: General Commercial | Commercial General, CG | |
(b) Purpose.
The Mixed-Use districts are intended to:
(1) Implement the vision, strategies, and future land use plan of the Grand Junction Comprehensive Plan;
(2) Create and enhance neighborhoods with variety of residential and commercial uses at a scale that complements the established surrounding areas;
(3) Provide for a mixed-use centers of activity that support but do not compete with each other;
(4) Allow for different types of compatible land uses close together in appropriate locations to shorten transportation trips and facilitate multi-modal transportation; and
(5) Encourage infill and redevelopment of commercial, residential, and mixed-use development within surrounding uses.
(c) Mixed-Use Neighborhood (MU-1).
(1) Intent.
The MU-1 district is intended to provide low intensity, neighborhood service, office, and limited retail uses that can include second residential uses and are compatible with adjacent residential neighborhoods. Development should be compatible and complementary in scale and appearance to a residential environment. MU-1 is appropriate as indicated in Table 21.03-2: Comprehensive Plan Implementation.
(2) Uses.
Permitted principal and accessory uses are identified in GJMC Chapter
21.04.
(3) Dimensions.
(i) The following dimensions apply in the MU-1 zone district:
(A) Structures that are designed for residential use only shall comply with the dimensional standards of the Residential zone district referenced here. Residential development shall comply with the density standards provided for MU-1.
(B) Structures that are either mixed-use or nonresidential shall comply with the dimensional standards for MU-1 provided here.
Lot Standards |
|---|
Residential Standards |
Applicable district standards [1] | RM-8 or RM-12 |
Minimum density [2] | 8 du/acre |
Mixed-Use Lot Standards |
Lot area (minimum, feet) | 4,000 |
Lot width (minimum, feet) | 50 |
Lot coverage (maximum) | 70% |
Parking, Loading, Service |
Access and location | Side or Rear |
Use Limits |
Retail uses require a Conditional Use Permit on lots with a Comprehensive Plan land use designation including "Residential" in the title. |
Building Standards |
Setbacks: Principal Structure (minimum, feet) [3] |
A | Front [4] | 5/0 |
B | All Others | 0 |
Setbacks: Accessory Structure (minimum, feet) |
| Front | 25 |
| Side | 0 |
| Rear | 0 |
Height (maximum, feet) |
C | Height | 40 |
Gross Floor Area (maximum, square feet) |
| Office | 30,000 |
Notes: [1] Either district may be chosen at rezoning; the chosen district shall be applied consistently. [2] See § 21.14.010(a). [3] Building location subject to easement and sight zone requirements; see Title 29, Transportation Engineering Design Standards, Appendix. [4] See § 21.03.040(e)(5)(i) for 0-foot setback requirements. |
(d) Mixed-Use Light Commercial (MU-2).
(1) Intent.
The MU-2 district is intended to accommodate commercial, employment, multi-unit, and other uses along transportation corridors to promote development that is comfortably accessible via all modes of transportation, including motor vehicles, bicycles, and walking. Commercial uses in the MU-2 district may be somewhat larger in scale and more flexible than the MU-1 district, including more auto-oriented uses such as gas stations. While ground stories along streets are intended for commercial uses, the upper stories are appropriate for residential and/or office uses. MU-2 is appropriate as indicated in Table 21.03-2: Comprehensive Plan Implementation.
(2) Uses.
Permitted principal and accessory uses are identified in GJMC Chapter
21.04.
(3) Dimensions.
(i) The following dimensions apply in the MU-2 zone district:
(A) Structures that are designed for residential use only shall comply with the dimensional standards of the Residential zone district referenced here. Residential development shall comply with the density standards provided for MU-2.
(B) Structures that are either mixed-use or nonresidential shall comply with the dimensional standards for MU-2 provided here.
Lot Standards |
|---|
Residential Standards |
Applicable district standards [1] | RH-16 or RH-24 |
Minimum density [2] | 16 du/acre |
Mixed-Use Lot Standards |
Lot area (minimum, feet) | 20,000 |
Lot width (minimum, feet) | 50 |
Lot coverage (maximum) | 100% |
Parking, Loading, Service |
Access and location: alley where available, otherwise side or rear |
Building Standards |
|---|
Setbacks: Principal Structure (minimum, feet) [3] |
A | Front [4] | 5/0 |
B | All Others | 0 |
Setbacks: Accessory Structure (minimum, feet) |
| Front | 25 |
| Side | 0 |
| Rear | 10 |
Height (maximum, feet) |
C | Height | 65 |
Use Limits |
Outdoor storage is not allowed within the front setback. |
Notes:[1] Either district may be chosen at rezoning; the chosen district shall be applied consistently. [2] See § 21.14.010(a). [3] Building location subject to easement and sight zone requirements; see Title 29, Transportation Engineering Design Standards, Appendix. [4] See § 21.03.040(e)(5)(i) for 0-foot setback requirements. |
(e) Mixed-Use Downtown (MU-3).
(1) Intent.
The MU-3 Downtown district is intended to provide highly walkable downtown retail, service, office, lodging, and mixed uses with ground story storefronts and upper story residential, lodging, and office uses. Downtown Grand Junction is intended to be attractive to both residents and visitors and should include active public spaces and a range of community amenities. The scale of new development and redevelopment can be larger than current structures but must incorporate transitions between larger and smaller structures. Retaining the historic character of Downtown is an important priority to balance with the consideration of new and redevelopment. MU-3 is appropriate as indicated in Table 21.03-2: Comprehensive Plan Implementation.
(2) Uses.
Permitted principal and accessory uses are identified in GJMC Chapter
21.04.
(3) Dimensions.
(i) The following dimensions apply in the MU-3 zone district:
Lot Standards |
|---|
Residential Standards |
Minimum density [1] | 8 du/acre |
Mixed-Use Lot Standards |
Lot area (minimum, feet) | n/a |
Lot width (minimum, feet) | n/a |
Lot coverage (maximum) | 100% |
Parking, Loading, Service |
Access: alley where available, otherwise side or rear |
Location: side or rear |
Use Limits |
Outdoor Entertainment and Recreation uses require a Conditional Use Permit on lots adjacent to a residential zone district. |
Building Standards |
Setbacks: Principal Structure (minimum, feet) |
A | Front | 0 |
B | All Others | 0 |
Setbacks: Accessory Structure (minimum, feet) |
| Front | 0 |
| Side | 0 |
| Rear | 0 |
Height (maximum, feet) |
C | Height | 80 |
(4) District Specific Standards.
(i) Parking Location.
(A) When parking, either commercial or private, is the principal use on a lot there shall be a thirty-foot front setback to the edge of the parking area.
(B) When parking, either commercial or private, is an accessory use on a lot, there shall be at least a six-foot front setback to the edge of the parking area.
(f) Commercial General (CG).
(1) Intent.
The CG zone district is intended for auto-oriented retail commercial and commercial services, wholesale, and warehouse-facilities. This district allows outdoor storage and limited outdoor operations. In some areas of the community, CG accommodates truck traffic. This district is intended to be located along corridors where proximity to residential and walkable mixed-use development is limited. CG is appropriate as indicated in Table 21.03-2: Comprehensive Plan Implementation.
(2) Uses.
Permitted principal and accessory uses are identified in GJMC Chapter
21.04.
(3) Dimensions.
(i) The following dimensions apply in the CG zone district:
(A) Structures that are designed for residential use only shall comply with the dimensional standards of the Residential zone district referenced here.
(B) Structures that are either mixed-use or nonresidential shall comply with the dimensional standards for CG provided here.
Lot Standards |
|---|
Residential Standards |
Applicable district standards | RH-16 |
Minimum density [1] | n/a |
Mixed-Use Lot Standards |
Lot area (minimum, feet) | 20,000 |
Lot width (minimum, feet) | 50 |
Lot coverage (maximum) | 100% |
Parking, Loading, Service |
Access: Alley where available, otherwise side or rear |
Building Standards |
|---|
Setbacks: Principal Structure (minimum) [2] |
A | Front [3] | 5/0 |
B | All Others | 0 |
Setbacks: Accessory Structure (minimum) |
| Front | 25 |
| Side | 0 |
| Rear | 10 |
Height (maximum, feet) |
E | Height | 65 |
Use Limits |
Outdoor uses are not allowed in a front setback. |
Notes: [1] See § 21.14.010(a). [2] Building location subject to easement and sight zone requirements; see Title 29, Transportation Engineering Design Standards, Appendix. [3] See § 21.03.040(e)(5)(i) for 0-foot setback requirements. |
(Ord. 5304, 2/4/2026; Ord. 5279, 10/1/2025; Ord. 5267, 7/16/2025; Ord. No. 5260, 5/7/2025; Ord. No. 5242, 12/4/2024; Ord. 5218, 5/1/2024; Ord. 5190, 12/20/2023)