(a) Lighting Types and Efficiency.
(1) LED or other high efficiency light fixtures shall be used to the maximum extent practicable.
(2) All light fixtures shall generate at least 80 lumens per watt of energy consumed, as shown on the manufacturers' specifications for the fixture.
(3) All exterior lighting shall have a correlated color temperature (CCT) below 3,001 Kelvin degrees. The CCT of lighting may exceed 3,000 Kelvin if the Director determines that accurate color rendition is crucial to public safety, which shall be reasonably given. In no case shall the CCT of such lighting exceed 5,000 Kelvin.
(b) Lighting Height.
No light fixtures shall be mounted more than 35 feet above the ground unless as a part of an approved outdoor recreational facility or outdoor amphitheater.
(c) Shielding and Light Trespass.
(1) All light fixtures shall be aimed and shielded so that the direct illumination shall be confined to the property boundaries of the light source. Lighting shall not be aimed onto adjacent properties, except in cases of shared parking, shared pedestrian pathways, or for coordinated development sites spanning multiple parcels.
(2) Lighting fixtures shall not be directly visible from adjacent roadways or residential uses and shall not interfere with the safe operation of vehicles moving on or near the site.
(3) Light sources shall be concealed or shielded with luminaires with cut-offs with an angle not exceeding 90° to minimize the potential for glare and unnecessary diffusion on adjacent properties.
Figure 11.05-1 Light Shielding |
(4) Light levels measured at the property line of the development site shall not exceed 0.2 footcandles as a direct result of the on-site lighting.
(d) Lighting Output Levels.
All lighting used to illuminate buildings, parking lots, walkways, or other site features, with the exception of lighting for public streets, shall comply with the following minimum and maximum outputs.
Table 21.11-1: Lighting Level Requirements |
|---|
Area | Minimum (footcandles) | Maximum (footcandles) |
|---|
Building Entries (Nonresidential) | 1.0 | 10.0 |
Bicycle Paths and Pedestrian Walkways | 0.6 | 10.0 |
Loading and Unloading Platforms | 5.0 | 20.0 |
Parking Areas | 0.6 | 10.0 |
Playgrounds | 5.0 | 10.0 |
Under-Canopy Areas | 5.0 | 20.0 |
(e) Lighting Controls.
(1) Floodlights shall not be used to light all or any portion of any building facade between the hours of 10:00 p.m. and 6:00 a.m.
(2) All exterior lighting not necessary for security purposes shall be reduced, activated by motion sensor devices, or turned off during non-operating hours. Any illumination between 10:00 p.m. and sunrise shall use full cutoff light fixtures and be reduced to levels sufficient for security purposes only.
Figure 11.05-2 Full Cutoff Light Fixtures |
(Ord. 5263, 6/18/2025; Ord. 5190, 12/20/2023)