(a)
Table 17.0301(a), Bulk and Dimensional Standards, addresses the requirements applicable to the development or use of a lot in a residential zoning district.
Table 17.0301(a) | ||||||||
|---|---|---|---|---|---|---|---|---|
Bulk and Dimensional Standards | ||||||||
Standard | ER | Rs-1 | Rs-2 | Rs-3 | Rs-4 | Rs-5 | Rd-1 | Rm-1 |
Lot standards (minimum) | ||||||||
Lot area (square feet) | 3 acres | 21,780 | 15,000 | 10,500 | 8,000 | 5 acres | 15,000 | 15,000 |
Lot area/DU (square feet) | — | — | — | — | — | — | 7,500 | 1 |
Lot width3 (feet) | 200 | 90 | 80 | 70 | 60 | 300 | 100 | 100 |
Yard setbacks (minimum)4 | ||||||||
Front (feet) | 50 | 30 | 30 | 30 | 25 | 1 | 30 | 302 |
Street facing side (feet) | 50 | 30 | 30 | 30 | 25 | 1 | 30 | 302 |
Interior side (feet) | 30 | 10 | 10 | 10 | 8 | 1 | 10 | 102 |
Rear (feet) | 100 | 30 | 30 | 30 | 25 | 1 | 30 | 252 |
Building standards (maximum) | ||||||||
Height (feet) | 35 | 35 | 35 | 35 | 35 | 1 | 35 | 50 |
Building coverage | 10% | 30% | 30% | 40% | 50% | 1 | 50% | 50% |
Lot coverage | — | — | — | — | — | 1 | — | 70% |
NOTES: | ||||||||
1As detailed in Article IV, Use Specific Standards. | ||||||||
2No multifamily structure shall be located closer than 50 feet to a single-family district line. | ||||||||
3An additional 10 feet of lot width shall be required for corner lots. | ||||||||
4Setbacks from wetlands shall be a minimum of 15 feet with a five-foot undisturbed buffer. | ||||||||
(b)
Table 17.0301(b), Bulk and Dimensional Standards, addresses the requirements applicable to the development or use of a lot in a nonresidential zoning district with the exception of the DTS Drexel Town Square District. The bulk and dimensional standards for the DTS Drexel Town Square District shall be pursuant to those established in the General Development Plan and Regulating Plan for the Drexel Town Square Mixed-Use Planned Development District, as amended.
Table 17.0301(b) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
Bulk and Dimensional Standards | |||||||||
Standard | A-1 | B-2 | B-3 | B-4 | B-6 | Lm-1 | M-1 | I-1 | P-1 |
Lot standards (minimum) | |||||||||
Lot area (square feet) | 5 acres | 10,000 | 10,000 | 30,000 | 40,000 | 1 acre | 1 acre | — | — |
Lot width (feet) | 150 | 75 | 75 | 150 | 150 | 150 | 200 | — | — |
Yard setbacks (minimum)1 | |||||||||
Front (feet) | 30 | 25 | 25 | 25 | 25 | 25 | 40 | 30 | 25 |
Street facing side (feet) | 30 | 25 | 25 | 25 | 25 | 25 | 40 | 30 | 25 |
Interior side (feet) | 10 | 20 | 20 | 15 | 10 | 15 | 20 | 50 | 25 |
Rear (feet) | 100 | 25 | 25 | 25 | 15 | 25 | 20 | 50 | 25 |
Building standards (maximum) | |||||||||
Height (feet) | 35 | 45 | 55 | 50 | 80 | 50 | 55 | 55 | 35 |
Building coverage | 10% | 40% | 40% | 40% | 40% | 60% | 70% | 30% | 20% |
Lot coverage | — | 70% | 70% | 70% | 70% | 70% | 70% | 70% | 70% |
NOTES: | |||||||||
1Setbacks from wetlands shall be a minimum of 15 feet with a five-foot undisturbed buffer. | |||||||||