Storm sewers and drainage improvements shall require a storm sewer permit with approved engineering plans with the following information:
A.
Plan map properly dimensioned and drawn to scale showing the location of the proposed storm sewer, drainage ditches and sewer appurtenances within the street right-of-way. Sewers and drainage ditches shall be stationed and all manholes, catch basins, and appurtenances shall be numbered;
B.
Location of existing above and below ground utilities in road right-of-way or adjacent easements;
C.
Location and dimensions of utility and drainage easements and location of all existing watercourses, ditches, trunk storm sewers, ponds and retention facilities connected with or adjacent to the proposed drainage facilities;
D.
Profiles of storm drains and drainage ditches with the following information:
E.
Suitable title plate on each drawing with street or sewer name, name and address of the developer, scale, date and the name, address and telephone number and stamp of the registered engineer responsible for the plan preparation;
F.
Structural details of any special manholes, catch basins, and appurtenances including drop manholes, retention control manholes, outlet structures, pumping stations, diversion structures, etc.
(Ord. 1853 § 2 (Exh. B), 2018)