(a)
The International Building Code (I.B.C.) Chapters 1 through 12, 14 through 28, 30 through 35, and Appendices A, J, and K (2021 Edition) published by the International Code Council (I.C.C.) is expressly referred to and adopted as the building code of the city, and by this reference and adoption made a part of this chapter as if fully set forth herein, save and except those specific deletions, amendments, and additions made in subsection (b) of this section. A copy of said Building Code and Appendices shall be filed and kept in the office of the city clerk.
(b)
The following provisions designated "deletion" are deleted and excepted from the International Building Code chapters and appendices adopted in subsection (a) of this section. The following provisions designated "addition" are added to the International Building Code chapters and appendices adopted in subsection (a) of this section. The following provisions designated "amendment" are amendments to the International Building Code chapters and appendices adopted in subsection (a) of this section.
(1)
Amendments to Cross-References. The I.B.C. is amended by deleting all the references to the "ICC Electrical Code or NFPA 70" and replacing them with "National Electrical Code" as adopted under Chapter 19.12 KMC, by deleting all references to the "International Fuel Gas Code" and all references to the "International Plumbing Code" and replacing them with "Uniform Plumbing Code" as adopted under Chapter 19.14 KMC, and by deleting all the references to the "International Property Maintenance Code" and replacing them with the "Uniform Code for the Abatement of Dangerous Buildings" as adopted under Chapter 19.28 KMC.
(2)
Amendment. Chapter 1, Section 109.2 (Schedule of permit fees) of the I.B.C. is amended as follows:
109.2 Fee schedule. Building permit and plan review fees shall be assessed in accordance with the provisions of this subsection. |
109.21 Alternations, additions, changes in occupancies, and new R-3 (one- and two-family dwellings). The base permit fee for each permit application for alterations, changes in occupancy, and new R-3 (detached one- and two-family dwellings) shall be computed based on Table 109.2.1. |
Table 109.2.1 Building Permit Fees | ||
|---|---|---|
TOTAL VALUATION | FEE | |
$0.00 to $500.00 | $23.50 | |
$500.01 to $2,000.00 | $23.50 for the first $500.00 plus $3.05 for each additional $100.00, or fraction thereof, to and including $2,000.00 | |
$2,000.01 to $25,000.00 | $69.25 for the first $2,000.00 plus $14.00 for each additional $1,000.00, or fraction thereof, to and including $25,000.00 | |
$25,000.01 to $50,000.00 | $391.25 for the first $25,000.00 plus $10.10 for each additional $1,000.00, or fraction thereof, to and including $50,000.00 | |
$50,000.01 to $100,000.00 | $643.75 for the first $50,000.00 plus $7,00 for each additional $1,000.00, or fraction thereof, to and including $100,000.00 | |
$100,000.01 to $500,000.00 | $993.75 for the first $100,000.00 plus $5.60 for each additional $1,000.00, or fraction thereof, to and including $500,000.00 | |
$500,000.01 to $1,000,000.00 | $3,233.75 for the first $500,000.00 plus $4.75 for each additional $1,000.00, or fraction thereof, to and including $1,000,000.00 | |
$1,000,000.01 and up | $5,608.75 for the first $1,000,000.00 plus $3.65 for each additional $1,000.00, or fraction thereof | |
Other Inspections and Fees: | ||
1. Inspections outside of normal business hours (minimum charge – two (2) hours) | $57.00 per hour 1 | |
2. Inspections for which no fee is specifically indicated (minimum charge one-half hour) | $57.00 per hour 1 | |
3. Additional plan review required by changes, additions or revisions to plans (minimum charge one-half hour) | $57.00 per hour 1 | |
4. For use of outside consultants for plan checking and inspections, or both | Actual amount paid2 | |
1. Or the total hourly cost to the city, whichever is the greatest. This cost shall include supervision, overhead, equipment, hourly wages, and fringe benefits of the employee involved. |
2. Actual costs include administrative and overhead costs. |
109.2.2 New construction valuation schedule, excluding new R-3 (one- and two-family dwellings). Valuation for new construction other than new R-3 (detached one- and two-family dwellings) will be computed based on the most recent Building Valuation Data - Members published by the International Code Council times a regional multiplier of 1.3. The valuation shall be calculated using the dollar per square foot method. The area of the building shall be the gross floor area; the total horizontal area of all floors of a building, measured between exterior faces of exterior walls, including interior balconies, mezzanines, stairwells, elevator shafts, ventilation shafts, etc., but excluding area without floor structure in atria. The building official shall then use the valuation determined under this Section 109.2.2 or Sections 109.2.2.1 or 109.2.2.2 to determine the base permit fee as following: |
Group (2021 International Building Code) | IA | IB | IIA | IIB | IIIA | IIIB | IV | VA | VB |
|---|---|---|---|---|---|---|---|---|---|
A-1 Assembly, theaters, with stage | 298.55 | 288.43 | 280.93 | 269.54 | 253.09 | 245.77 | 260.87 | 235.34 | 226.84 |
A-1 Assembly, theaters, without stage | 273.51 | 263.39 | 255.89 | 244.51 | 228.06 | 220.73 | 235.84 | 210.31 | 201.80 |
A-2 Assembly, nightclubs | 233.39 | 226.42 | 220.85 | 211.80 | 199.64 | 194.14 | 204.26 | 180.65 | 174.48 |
A-2 Assembly, restaurants, bars, banquet halls | 232.39 | 225.42 | 218.85 | 210.80 | 197.64 | 193.14 | 203.26 | 178.65 | 173.48 |
A-3 Assembly, churches | 276.84 | 266.72 | 259.22 | 247.83 | 231.83 | 225.68 | 239.17 | 214.08 | 205.57 |
A-3 Assembly, general, community halls, libraries, museums | 231.62 | 221.50 | 213.00 | 202.61 | 185.16 | 178.84 | 193.94 | 167.42 | 159.91 |
A-4 Assembly, arenas | 272.51 | 262.39 | 253.89 | 243.51 | 226.06 | 219.73 | 234.84 | 208.31 | 200.80 |
B-Business | 240.93 | 232.14 | 224.41 | 213.38 | 194.94 | 187.44 | 204.97 | 171.50 | 163.65 |
E Education | 253.16 | 244.50 | 238.07 | 227.82 | 212.65 | 201.92 | 219.97 | 185.88 | 180.09 |
F-1 Factory and industrial, moderate hazard | 142.51 | 135.81 | 128.20 | 123.31 | 110.60 | 105.32 | 118.02 | 91.13 | 85.44 |
F-2 Factory and industrial, low hazard | 141.51 | 134.81 | 128.20 | 122.31 | 110.60 | 104.32 | 117.02 | 91.13 | 84.44 |
H-1 High Hazard, explosives | 133.05 | 126.35 | 119.74 | 113.85 | 102.42 | 96.14 | 108.56 | 82.95 | N.P. |
H234 High Hazard | 133.05 | 126.35 | 119.74 | 113.85 | 102.42 | 96.14 | 108.56 | 82.95 | 76.26 |
H-5 HPM | 240.93 | 232.14 | 224.41 | 213.38 | 194.94 | 187.44 | 204.97 | 171.50 | 163.65 |
I-1 Institutional, supervised environment | 240.35 | 232.11 | 225.21 | 216.12 | 198.77 | 193.28 | 216.40 | 178.22 | 172.87 |
I-2 Institutional, hospitals | 403.60 | 394.81 | 387.08 | 376.05 | 356.54 | N.P. | 367.65 | 333.11 | N.P. |
I-2 Institutional, nursing homes | 280.29 | 271.50 | 263.77 | 252.74 | 235.00 | N.P. | 244.34 | 211.57 | N.P. |
I-3 Institutional, restrained | 273.98 | 265.19 | 257.46 | 246.43 | 229.58 | 221.08 | 238.03 | 206.14 | 196.29 |
I-4 Institutional, day care facilities | 240.35 | 232.11 | 225.21 | 216.12 | 198.77 | 193.28 | 216.40 | 178.22 | 172.87 |
M Mercantile | 174.08 | 167.12 | 160.55 | 152.50 | 140.10 | 135.60 | 144.96 | 121.12 | 115.94 |
R-1 Residential, hotels | 242.77 | 234.53 | 227.63 | 218.55 | 200.90 | 195.42 | 218.82 | 180.35 | 175.00 |
R-2 Residential, multiple family | 203.34 | 195.11 | 188.20 | 179.12 | 162.64 | 157.15 | 179.40 | 142.08 | 136.73 |
R-3 Residential, one- and two-family d | 189.34 | 184.22 | 179.47 | 175.04 | 169.94 | 163.79 | 172.07 | 157.66 | 148.33 |
R-4 Residential, care/assisted living facilities | 240.35 | 232.11 | 225.21 | 216.12 | 198.77 | 193.28 | 216.40 | 178.22 | 172.87 |
S-1 Storage, moderate hazard | 132.05 | 125.35 | 117.74 | 112.85 | 100.42 | 95.14 | 107.56 | 80.95 | 75.26 |
S-2 Storage, low hazard | 131.05 | 124.35 | 117.74 | 111.85 | 100.42 | 94.14 | 106.56 | 80.95 | 74.26 |
U Utility, miscellaneous | 104.03 | 98.14 | 92.46 | 88.40 | 79.71 | 73.77 | 84.55 | 62.84 | 59.88 |
a. Private Garages use Utility, miscellaneous |
b. For shell only buildings deduct 20 percent |
c. N.P. = not permitted |
d. Unfinished basements (Group R-3) = $23.20 per sq. ft. |
FEE SCHEDULE | |
|---|---|
New Commercial Construction Valuation per Valuation Schedule times 1.3 regional multiplier | Base Building Permit Fee Established By: |
$1.00 to $500,000 | Valuation x $0.015 |
$500,001 to $1,000,000 | Valuation x $0.010 |
$1,000,000 to $5,000,000 | Valuation x $0.008 |
$5,000,000 and up | Valuation x $0.006 |
1092.2.1 Fabric structures. The valuation for base permit fees for temporary and permanent fabric structures shall be calculated at $30 per square foot. |
109.2.2.2 Other valuations. Valuations used to determine base permit fees for projects not included in the Valuation Table or Sections 109.2.1 or 109.2.2.1, including decks, shall be determined by the permittee and verified by the building official. The building official may require additional documentation to verify valuation. |
109.2.3 Plan review fees. In addition to the base permit fee, a plan review fee equal to 65% of the base permit fee shall be paid except that there is no plan review fee for detached one- and two-family dwellings. If plans are so incomplete or are revised to the extent that requires a new plan review, the plan review fee will be the same as for new plans. Where there are phased approvals under Section 107, the plan review fee for such phased work shall be equal to 65% of the base permit fee for the value of the phased work. |
(3)
Amendment. Chapter 1, Section 109.3 (Building permit valuations) of the I.B.C. is amended as follows:
109.3 Building permit valuations. The applicant for a building permit shall provide an estimated permit value at time of application. Permit valuations shall include total value of work, including materials and labor, for which the permit is being issued, such as structural, electrical, gas, mechanical, and plumbing equipment and other permanent systems. If, in the opinion of the city building official, the valuation is underestimated on the application, the permit shall be denied, unless the applicant can show detailed estimates to meet the approval of the building official. Final building permit valuation shall be set by the building official. The valuation for all new construction, other than new R-3 (detached one- and two-family dwellings), must be based on the Valuation Schedule established in Section 109.2. The valuation for fabric structures must be based on the valuation established by Section 109.2.2.1. |
(4)
Amendment. Chapter 3, Section 305.2 (Group E, day care facilities) of the I.B.C. is amended to read as follows:
305.2 Group E, Group E, day care facilities. This group includes buildings and structures or portions thereof occupied by more than five children including those related to the staff older than 2-1/2 years of age who receive educational, supervision or personal care services for less than 24 hours per day. |
(5)
Amendment. Chapter 3, Section 308.4.1 (Five or fewer persons receiving care) of the I.B.C. is amended to read as follows:
308.4.1 Five or fewer persons receiving custodial care. A facility with five or fewer persons including persons related to the staff receiving custodial care shall be classified as Group R-3 or shall comply with the International Residential Code provided an automatic sprinkler system is installed in accordance with Section 903.3.1.3 or Section P2904 of the International Residential Code. |
(6)
Amendment. Chapter 3, Section 308.5 (Institutional Group I-4, day care facilities) of the I.B.C. is amended to read as follows:
308.5 Institutional Group I-4, day care facilities. Institutional Group I-4 occupancy shall include buildings and structures occupied by more than five persons of any age, including children related to the staff, who receive custodial care for fewer than 24 hours per day. This group shall include, but not be limited to, the following: |
Adult day care |
Child day care |
(7)
Addition. Chapter 3, Section 310.1 (Residential Group R) of the I.B.C. is amended by adding a new sentence at the end of the first paragraph to read as follows:
For facilities within this occupancy classification that have occupants needing physical assistance to respond in emergency situations, see Section 405 of the 2021 International Fire Code. |
(8)
Amendment. Paragraph 1 of Chapter 4, Section 406.3.4 (Separation) of the I.B.C. is amended as follows:
406.3.2.1 Dwelling unit separation. Private garages attached to dwelling units shall have the interior finished throughout with gypsum board. The private garage shall be separated from the dwelling unit and its attic area by means of gypsum board, not less than 5/8-inch (15.9 mm) Type X, applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than a 5/8- inch (15.9 mm) Type X gypsum board or equivalent and 5/8-inch (15.9 mm) Type X gypsum board applied to structures supporting the separation from habitable rooms above the garage. Gypsum board shall be fire taped at minimum. Door openings between a private garage and the dwelling unit shall be equipped with either solid wood doors or solid or honeycomb core steel doors not less than 13/8 inches (34.9 mm) in thickness, or doors in compliance with Section 716.2.2.1 with a fire protection rating of not less than 20 minutes. Doors shall be self-closing and self-latching. |
(9)
Addition. Chapter 5, Section 510.10 (Special provisions) of the I.B.C. is amended by adding a new Section 510.10 to read as follows:
510.10 Day care facilities. Facilities that are operated in a primary residence (Group R-3) between the hours of 6:00 a.m. and 10:00 p.m., and accommodating up to a total of 12 children of any age may use the second story of the building without providing an automatic sprinkler system, or complying with Table 508.4, Table 602, and Type VA requirements set out in Table 503, if all other applicable legal provisions for a Group E occupancy are met. |
(10)
Amendment. Chapter 5, Table 509 (Incidental Uses) of the I.B.C. is amended by changing the wording in the first row of the first column to read as follows:
Furnace rooms in Group E, I, and R-1, R-2, and R-4 occupancies regardless of Btu input, and furnace rooms of all other occupancies where the largest piece of equipment is over 400,000 Btu per hour input. |
(11)
Addition. Chapter 3, Section 305 Educational Group E of the I.B.C. is amended by adding Section 305.4 to read as follows:
305.4 Combination shops related to an educational facility shall be considered an F-1 occupancy and shall be separated from the E occupancy according to Table 508.4. |
(12)
Amendment. Chapter 9, Section 903.2.3 (Group E) of the I.B.C. is amended to read as follows:
903.2.3 Group E. An automatic sprinkler system must be provided throughout all buildings with Group E occupancies. The use of a fire wall or barrier does not establish a separate building or fire area for purposes of this section. |
Exception: Buildings with Group E occupancies having an occupant load of 49 or less. |
(A) An automatic sprinkler system must also be provided for every portion of educational building below the level of exit discharge. |
(B) Home day care uses that are licensed to care for more than five persons between the hours of 10:00 p.m. and 6:00 a.m. must be equipped with an automatic sprinkler system designed and installed as described in Section 903.3.1.3 or an equivalent system approved by the building official. |
(13)
Addition. Chapter 9, Section 903.2.8 (Group R) of the I.B.C. is amended by adding a new Section 903.2.8.5 to read as follows:
903.2.8.5 Rental cabins occupied for less than 30 days with potable water will be considered R-1 and will be required to comply with Section 903.2.8. |
(14)
Addition. Chapter 9, Section 903.2.8 (Group R) of the I.B.C. is amended by adding a new Section 903.2.8.6 to read as follows:
903.2.8.6 Group R-2. An automatic sprinkler system or a residential sprinkler system installed in accordance with Section 903.3.1.2 must be provided throughout all buildings with a Group R-2 fire area that are more than two stories in height, including basements, or that have more than four dwelling units or 16 sleeping rooms. |
(15)
Deletion. Chapter 9, Section 906.1 (Where required) of the I.B.C. is amended by deleting all exceptions.
(16)
Amendment. Chapter 9, Section 907.2.1 (Group A) is deleted and replaced with the following:
907.2.1 Group A. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in Group A occupancies where the occupant load due to the assembly occupancy is 100 or more. Group A occupancies not separated from one another in with Section 707.3.10 of the International Building Code shall be considered as a single occupancy for the purposes of applying this section. Portions of Group E occupancies occupied for assembly purposes shall be provided with a fire alarm system as required for the Group E occupancy. Delete exception. |
(17)
Deletion. Chapter 9, Section 907.2.3 (Group E) of the I.B.C. is amended by deleting Exception 3.
(18)
Addition. Chapter 9, Section 907.2.3 (Group E) of the I.B.C. is amended by adding a Section 907.2.3.1 to read as follows:
907.2.3.1 Rooms used for sleeping or napping purposes with a day care use of a Group E occupancy must be provided with Single- and multiple-station smoke which alarms shall be installed in accordance with Section 907.2.11. |
(19)
Deletion. Chapter 9, Section 907.2.6.1 (Group I-1) of the I.B.C. is amended by deleting Exception 1.
(20)
Deletion. Chapter 9, Section 907.2.9.1 (Manual fire alarm system) of the I.B.C. is amended by deleting Exception 2.
(21)
Deletion. Chapter 9, Section 907.2.10.1 (Manual fire alarm system) of the I.B.C. is amended by deleting Exception 2.
(22)
Deletion. Chapter 9, Section 910.1 (General) of the I.B.C. is amended by deleting Exceptions 2 and 3.
(23)
Addition. Chapter 9, Section 915.2.1 (Dwelling units) of the I.B.C. is amended by adding a sentence at the end to read as follows:
At least one carbon monoxide detector or alarm shall be installed on each floor level |
(24)
Addition. A new sentence is added to Chapter 10, Section 1021.1 (General) of the I.B.C. to read as follows:
Exterior exit balconies shall be designed to minimize accumulation of snow or ice that impedes the means of egress. |
(25)
Deletion. Chapter 10, Section 1031.2 (Where required) of the I.B.C. is amended by deleting Exceptions 1 and 3.
(Ord. 2005 § 1, 2025)