Table 2306.2(3) UNBLOCKED Wood Structural Panel DIAPHRAGMS with Framing of Douglas-Fir Larch or Southern Pine Allowable (ASD) Unit Shear Capacities (pounds per foot) | ||||||||
|---|---|---|---|---|---|---|---|---|
Sheathing Grade | Common Nail Size | Minimum Fastener Penetration in Framing (in.) | Minimum Nominal Panel Thickness (in.) | Minimum Nominal Width of Nailed Face at Adjoining Panel Edges and Boundaries (in.) | SEISMIC | WIND | ||
6 in. Nail Spacing at diaphragm boundaries and supported panel edges | 6 in. Nail Spacing at diaphragm boundaries and supported panel edges | |||||||
Case 1 | Cases 2,3,4,5,6 | Case 1 | Cases 2,3,4,5,6 | |||||
Structural I | 8d | 1-3/8 | 3/8 | 2 3 | 240 265 | 180 200 | 335 370 | 252 280 |
10d | 1-1/2 | 15/32 | 2 3 | 285 320 | 215 240 | 400 447 | 300 335 | |
Sheathing and Single-Floor (DOC PS1 and PS2) | 6d | 1-1/4 | 3/8 | 2 3 | 165 185 | 125 140 | 230 260 | 175 195 |
8d | 1-3/8 | 3/8 | 2 3 | 215 240 | 160 180 | 300 335 | 225 252 | |
7/16 | 2 3 | 230 255 | 170 190 | 322 357 | 237 265 | |||
15/32 | 2 3 | 240 265 | 180 200 | 335 370 | 252 280 | |||
10d | 1-1/2 | 15/32 | 2 3 | 255 290 | 190 215 | 357 405 | 265 300 | |
19/32 | 2 3 | 285 320 | 215 240 | 400 447 | 300 335 | |||
Notes: |
|---|
a. See AWC SDPWS for the following: For general construction requirements see 4.2.7. For specific requirements see 4.2.8.1 for wood structural panel diaphragms. See Appendix A for common nail dimensions. |
b. For species and grades of framing other than Douglas-Fir-Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the NDS (Table 12.3.3A). The Specific Gravity Adjustment Factor shall not be greater than 1. |
c. See AWC SDPWS Table 4.2C for Case definitions. |
d. See AWC SDPWS Table 4.2C for the apparent shear stiffness values (Ga). |
e. Tabulated nominal unit shear capacities are applicable for carbon steel smooth shank nails of the specified type and size. |
Table 2306.2(4) BLOCKED Wood Structural Panel DIAPHRAGMS with Framing of Douglas-Fir Larch or Southern Pine Allowable (ASD) Unit Shear Capacities (pounds per foot) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sheathing Grade | Common Nail Size | Minimum Nail Bearing Length in Framing Member or Blocking (in.) | Minimum Nominal Panel Thickness (in.) | Minimum Nominal Width of Nailed Face at Adjoining Panel Edges and Boundaries (in.) | SEISMIC | WIND | ||||||
Nail Spacing (in.) at diaphragm boundaries (all cases), at continuous panel edges parallel to load (Cases 3 & 4), and at all panel edges (Cases 5 & 6) | Nail Spacing (in.) at diaphragm boundaries (all cases), at continuous panel edges parallel to load (Cases 3 & 4), and at all panel edges (Cases 5 & 6) | |||||||||||
6 | 4 | 2-1/2 | 2 | 6 | 4 | 2-1/2 | 2 | |||||
Nail Spacing (in.) at other panel edges (Cases 1, 2, 3, & 4) | Nail Spacing (in.) at other panel edges (Cases 1, 2, 3, & 4) | |||||||||||
6 | 6 | 4 | 3 | 6 | 6 | 4 | 3 | |||||
Structural I | 8d | 1-3/8 | 3/8 | 2 3 | 270 300 | 360 400 | 530 600 | 600 675 | 377 420 | 505 560 | 742 840 | 840 945 |
10d | 1-1/2 | 15/32 | 2 3 | 320 360 | 425 480 | 640 720 | 730 820 | 447 505 | 595 672 | 895 1007 | 1022 1147 | |
Sheathing and Single-Floor (DOC PS1 and PS2) | 6d | 1-1/4 | 3/8 | 2 3 | 185 210 | 250 280 | 375 420 | 420 475 | 260 295 | 350 392 | 525 587 | 587 665 |
8d | 1-3/8 | 3/8 | 2 3 | 240 270 | 320 360 | 480 540 | 545 610 | 335 377 | 447 505 | 672 755 | 762 855 | |
7/16 | 2 3 | 255 285 | 340 380 | 505 570 | 575 645 | 357 400 | 475 532 | 707 797 | 805 902 | |||
15/32 | 2 3 | 270 300 | 360 400 | 530 600 | 600 675 | 377 420 | 505 560 | 742 840 | 840 945 | |||
10d | 1-1/2 | 15/32 | 2 3 | 290 325 | 385 430 | 575 650 | 655 735 | 405 455 | 540 602 | 805 910 | 917 1030 | |
19/32 | 2 3 | 320 360 | 425 480 | 640 720 | 730 820 | 447 505 | 595 672 | 895 1007 | 1022 1147 | |||
Notes: |
|---|
a. See AWC SDPWS for the following: For general construction requirements see 4.2.7. For specific requirements see 4.2.8.1 for wood structural panel diaphragms. See Appendix A for common nail dimensions. |
b. For species and grades of framing other than Douglas-Fir-Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the NDS (Table 12.3.3A). The Specific Gravity Adjustment Factor shall not be greater than 1. |
c. See AWC SDPWS Table 4.2A for Case definitions. |
d. See AWC SDPWS Table 4.2A for the apparent shear stiffness values (Ga). |
e. Tabulated nominal unit shear capacities are applicable for carbon steel smooth shank nails of the specified type and size. |
Table 2306.2(5) Blocked Wood Structural Panel DIAPHRAGMS with Framing of Douglas-Fir Larch or Southern Pine UTILIZING MULTIPLE ROWS OF FASTENERS (HIGH-LOAD DIAPHRAGMS) Allowable (ASD) Unit Shear Capacities (pounds per foot) | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sheathing Grade | Common Nail Size | Minimum Nail Bearing Length in Framing Member or Blocking (in.) | Minimum Nominal Panel Thickness (in.) | Minimum Nominal Width of Nailed Face at Adjoining Panel Edges and Boundaries (in.) | Lines of Nails | SEISMIC | WIND | ||||||
Nail Spacing (in.) at diaphragm boundaries (all cases), at continuous panel edges parallel to load (Cases 3 & 4), and at all panel edges (Cases 5 & 6) | Nail Spacing (in.) at diaphragm boundaries (all cases), at continuous panel edges parallel to load (Cases 3 & 4), and at all panel edges (Cases 5 & 6) | ||||||||||||
4 | 2-1/2 | 4 | 2-1/2 | ||||||||||
Nail Spacing (in.) at other panel edges (Cases 1, 2, 3, & 4) | Nail Spacing (in.) at other panel edges (Cases 1, 2, 3, & 4) | ||||||||||||
6 | 4 | 4 | 3 | 6 | 4 | 4 | 3 | ||||||
Structural I | 10d | 1-1/2 | 15/32 | 3 4 4 | 2 2 3 | 605 700 875 | 815 915 1220 | 875 1005 1285 | 1150 1290 1395 | 847 980 1225 | 1140 1280 1707 | 1225 1407 1800 | 1610 1805 1952 |
19/32 | 3 4 4 | 2 2 3 | 670 780 965 | 880 990 1320 | 965 1110 1405 | 1255 1440 1790 | 937 1092 1350 | 1232 1385 1847 | 1350 1555 1967 | 1757 2015 2505 | |||
23/32 | 3 4 4 | 2 2 3 | 730 855 1050 | 955 1070 1430 | 1050 1210 1525 | 1365 1565 1800 | 1022 1197 1470 | 1337 1497 2002 | 1470 1695 2135 | 1910 2190 2520 | |||
Sheathing and Single-Floor (DOC PS1 and PS2) | 10d | 1-1/2 | 15/32 | 3 4 4 | 2 2 3 | 525 605 765 | 725 815 1085 | 765 875 1130 | 1010 1105 1195 | 735 847 1070 | 1015 1140 1520 | 1070 1225 1582 | 1415 1547 1672 |
19/32 | 3 4 4 | 2 2 3 | 650 755 935 | 860 965 1290 | 935 1080 1365 | 1225 1370 1485 | 910 1057 1310 | 1205 1350 1805 | 1310 1512 1910 | 1715 1917 2080 | |||
23/32 | 3 4 4 | 2 2 3 | 710 825 1020 | 935 1050 1400 | 1020 1175 1480 | 1335 1445 1565 | 995 1155 1427 | 1310 1470 1960 | 1427 1645 2072 | 1870 2022 2190 | |||
Notes: |
|---|
a. See AWC SDPWS for the following: For general construction requirements see 4.2.7. For specific requirements see 4.2.8.1 for wood structural panel diaphragms. See Figure 4C for nailing diagrams. See Appendix A for common nail dimensions. |
b. For species and grades of framing other than Douglas-Fir-Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the NDS (Table 12.3.3A). The Specific Gravity Adjustment Factor shall not be greater than 1. |
c. See AWC SDPWS Table 4.2B for Case definitions. |
d. See AWC SDPWS Table 4.2B for the apparent shear stiffness values (Ga). |
e. Tabulated nominal unit shear capacities are applicable for carbon steel smooth shank nails of the specified type and size. |
TABLE 2306.3(4) WOOD STRUCTURAL PANEL SHEAR WALLS with Framing of Douglas-Fir Larch or Southern Pine Allowable (ASD) Shear Capacities (pounds per foot) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Sheathing Material | Minimum Nominal Panel Thickness (in.) | Minimum Fastener Penetration into Framing or Blocking (in.) | Nail Size (common) | SEISMIC | WIND | ||||||
Panel Edge Fastener Spacing (in.) | Panel Edge Fastener Spacing (in.) | ||||||||||
6 | 4 | 3 | 2 | 6 | 4 | 3 | 5 | ||||
Wood Structural Panels – Structural I | 3/8 7/16 15/32 | 1-3/8 | 8d | 200 255 280 | 200 395* 430* | 200 505* 550* | 200* 670* 730* | 322 357 392 | 505 552 602 | 645 707 770 | 855* 937* 1022* |
15/32 | 1-1/2 | 10d | 340 | 510* | 665* | 870* | 475 | 715 | 930* | 1217* | |
Wood Structural Panels – Sheathing (DOC PS 1 or PS 2) | 3/8 | 1-1/4 | 6d | 200 | 200 | 200 | 200* | 280 | 420 | 545 | 715* |
3/8 7/16 15/32 | 1-3/8 | 8d | 200 240 260 | 200 350 380* | 200 450* 490* | 200* 585* 640* | 307 335 365 | 447 490 532 | 575 630 685 | 742* 820* 895* | |
15/32 19/32 | 1-1/2 | 10d | 310 340 | 460* 510* | 600* 665* | 770* 870* | 435 475 | 645 715 | 840* 930* | 1077* 1217* | |
Plywood Siding | 3/8 | 1-1/4 1-3/8 | 6d 8d | 140 160 | 200 200 | 200 200 | 200* 200* | 195 225 | 295 335 | 385 435 | 505* 575* |
Notes: |
|---|
* Framing members and blocking at adjoining panel edges shall be 3" nominal or greater per AWC SDPWS Section 4.3.7.1, item 5. |
a. Where panels are applied on both faces of a wall and nail spacing is less than 6" on center on either side, panel joints shall be offset to fall on different framing members, or framing shall be 3" nominal or thicker at adjoining panel edges and nails at all panel edges shall be staggered. |
b. Where the width of framing members is required to be 3" nominal, two 2" nominal members shall be permitted provided they are fastened together to transfer the shear between members. |
c. Where 3/8" or 7/16" sheathing is used, studs shall not be spaced more than 16" on center. Otherwise, studs shall not be spaced at more than 24" on center. |
d. Where studs are spaced at 24" on center, nailing to intermediate framing shall be spaced at 6" on center maximum. Where studs are spaced less than 24" on center, nailing to intermediate framing shall be spaced at 12" on center maximum. |
e. Steel plate washers shall be provided at foundation anchor bolts as required by AWC SDPWS Section 4.3.6.4.3. When required, plate washers shall not be less than 0.229"x3"x3" in size. The hole in the plate washer shall be permitted to be diagonally slotted with a width of up to 3/16" larger than the bolt diameter and a slot length not to exceed 1-3/4", provided a standard cut washer is placed between the plate washer and the nut. |
f. Allowable shear values for 7/16" sheathing are permitted to be increased to values shown for 15/32" sheathing with the same nailing provided panels are applied with long dimension across studs. |
g. Galvanized nails shall be hot dipped or mechanically deposited. |
h. Nails shall be placed not less than 1/2" in from panel edges and not less than 3/8" from the edge of the connecting members for shears greater than 350 plf. Nails shall not be placed not less than 3/8" from panel edges and not less than 1/4" from the edge of the connecting members for shears of 350 plf or less. |
i. See AWC SDPWS for the following: For general construction requirements see 4.3.6. For specific requirements for wood structural panel shearwalls see 4.3.7.1. For shear wall aspect ratios and capacity adjustments see 4.3.3. For the apparent shear stiffness values (Ga), see Table 4.3A. See Appendix A for common nail dimensions. |
j. For species and grades of framing other than Douglas-Fir-Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-G)], where G = Specific Gravity of the framing lumber from the NDS (Table 12.3.3A). The Specific Gravity Adjustment Factor shall not be greater than 1. |
k. See AWC SDPWS Table 4.3A for additional notes. |