Maximum density | 20 dwelling units per gross acre. |
Minimum or maximum lot area | To be determined through the conditional use permit or site plan review process – see Chapter 22.68 or 22.72 FMC. |
Maximum height | 35 feet. A maximum 45-foot height may be authorized if 1 or more levels of structured parking are provided at or below grade level within the building footprint. For other exceptions, see FMC § 22.58.007. |
Minimum front yard setback | 25 feet for first 35 feet of building height. Portions of a building above 35 feet shall be stepped back an additional 10 feet from the underlying story wall plane. |
Minimum interior side yard setback | 8 feet for first 35 feet of building height. Portions of a building above 35 feet shall be stepped back an additional 10 feet from the underlying story wall plane. |
Minimum side street side yard setback | 15 feet for first 35 feet of building height. Portions of a building above 35 feet shall be stepped back an additional 10 feet from the underlying story wall plane. |
Minimum rear yard setback | 20 feet for first 35 feet of building height. Portions of a building above 35 feet shall be stepped back an additional 10 feet from the underlying story wall plane. |
Minimum dwelling structure separation | 10 feet for first 35 feet of building height. Portions of a building above 35 feet shall be stepped back an additional 10 feet from the underlying story wall plane. |
Exterior wall modulation | Building elevations greater than 40 feet in length, measured horizontally, shall incorporate wall plane projections or recesses having a depth of at least 4 feet for front and side street side yard elevations of duplexes, and 6 feet for all elevations of all other buildings. The projections or recesses shall extend at least 20% of the length of the elevation. No uninterrupted length of any elevation shall exceed 40 horizontal feet. See FMC § 22.64.009 for an illustration of this requirement. |
Articulation | Building elevations exceeding 20 feet in length, measured horizontally, shall incorporate a minimum of 2 articulation components, such as a stoop, porch, chimney or other substantial projections, windows, multiple contrasting siding materials, or substantial trim including a belt course, to visually and/or functionally break up flat, blank or undifferentiated elevations. Building elevations greater than 30 feet in length, measured horizontally, and exceeding 12 feet in height, measured from finished grade to top of wall where it connects to roof structure, shall incorporate a minimum of 3 articulation components. |
Maximum lot coverage for structures | 55% for all structures combined. 65% for all structures combined if at least 50% of required parking is provided at or below grade level within the building footprint. |
Maximum impervious surface coverage | 75% for all structures and other impervious surfaces combined. |
Additional specific use and structure regulations. | |
Parking and circulation | |
Landscaping regulations | |
Design standards | See Chapter 22.64 FMC. See also multifamily design standards and guidelines adopted by reference in Chapter 22.63 FMC. |
Calculations resulting in a fraction shall be rounded to the nearest whole number with .50 being rounded up. |
(Ord. 1246 § 7, 2000; Ord. 1272 § 5, 2001; Ord. 1311 § 7, 2002; Ord. 1562 § 16, 2015; Ord. 1611 § 10, 2018)