The purpose of the West Main pedestrian overlay is to support high-quality pedestrian oriented design elements along West Main Street in the West Kelso neighborhood. Active first floor nonresidential uses are required along the street while allowing for a mix of uses on the upper floors. Pedestrian oriented design elements include transparent first floor storefronts, overhead weather protection, building width and articulation requirements, pedestrian amenities, reduced off-street parking requirements, and zero or minimal building setbacks. The intent of this zone is to require pedestrian oriented design while allowing for creativity in the design of sites, buildings, and pedestrian space.
A. Applicability. The boundaries of the West Main pedestrian overlay (WMPO) are centered on West Main Street between Cowlitz Way West and First Avenue in West Kelso as shown on the official zoning map.
1. The West Kelso subarea plan is a resource document that may be a helpful reference source when reviewing these standards. In the event of a conflict between these provisions and the subarea plan, these provisions shall prevail unless otherwise determined by the city.
2. The city may approve alternative methods that meet or exceed these standards that are consistent with the provisions of the West Kelso subarea plan.
3. Project sponsors are encouraged to schedule a preapplication meeting with department of community development staff to discuss the applicability of these standards.
B. Design Review Required.
1. The construction of any new building, the substantial alteration of the exterior appearance of any structure, or the installation of any sign in the West Main pedestrian overlay must comply with the standards of this section.
a. The substantial alteration of the exterior appearance of an existing structure includes the alteration, addition to or modification of the primary and/ or secondary facade of the subject structure, which fundamentally alters the facade.
2. Minor alterations, emergency repairs, ordinary maintenance and repairs, interior remodeling or decorations, as determined by the city, are exempt from the requirements of this pedestrian overlay.
C. Proposed developments within the West Main pedestrian overlay shall be subject to the following standards:
1. Civic Spaces.
a. Sidewalks shall be designed to function as public open spaces bordered by buildings, in addition to facilitating pedestrian movement. Buildings shall be designed to enhance the pedestrian experience through the use of such features as building articulation (i.e., variations in building materials, surface texture, windows, doors, porches and other facade features), landscaping, lighting and signage without encumbering the efficient movement and parking of vehicles.
b. Development at street intersections shall enhance intersections in ways that extend beyond functional needs through the location of building entries and the incorporation of building details, street lighting, landscaping and signage which respect and conform to the character of existing structures at the intersection.
c. Overhead utilities shall be relocated underground unless it is demonstrated that undergrounding of utilities is not practical and affirmed by the service provider.
2. Buildings. New construction shall preserve and continue the traditional block development pattern of the city by creating buildings that follow in scale and proportion the traditional modularity of existing block faces with buildings constructed to street property lines and main pedestrian access to the building is from the street. New development and redevelopment shall be designed with the same scale and proportions as would be found within the traditional block pattern with buildings constructed to the property line and with pedestrian access from the street.
3. Architectural Elements and Materials.
a. Building design elements, details and massing shall create a well-proportioned and unified building form and exhibit an overall architectural concept. Buildings shall exhibit form and features identifying the functions within the building. In general, the roofline or top of the structure shall be clearly distinguished from its facade walls.
b. The design of new buildings shall incorporate architectural features, elements and details to achieve a good human scale.
c. Building exteriors shall be constructed of durable and maintainable materials that are attractive even when viewed up close. Materials that have texture, pattern, or lend themselves to a high quality of detailing are encouraged.
d. Buildings shall avoid large blank walls facing the street, especially near sidewalks. Where blank walls are unavoidable, they shall receive design treatment to increase pedestrian comfort and interest.
e. A minimum of sixty percent of the first floor shall be transparent between thirty inches and twelve feet.
f. Provide weather protection at least five feet deep along eighty percent of the facade facing the street.
g. The primary building entrance shall be from West Main Street or Catlin Street for those properties that do not have street frontage on West Main Street.
4. Parking and Access.
a. Entries shall be clearly identifiable and visible from the street.
b. Siting shall minimize the impact of automobile parking and driveways on the pedestrian environment, adjacent properties and pedestrian safety. Off-street parking areas on a commercial street front shall be minimized and where possible shall be located behind or under a building.
c. Building sites shall locate service elements like trash dumpsters, loading docks and mechanical equipment away from the street front where possible. When elements such as dumpsters, utility meters, mechanical units and service areas cannot be located away from the street front, they shall be situated and screened from view and shall not be located in the pedestrian right-of-way.
d. Off-Street Parking and Access. The off-street parking standards contained herein supersede the parking requirements in Chapter
17.30 within the WMPO.
i. One space per residential unit shall be provided unless reduced by the city based on a site-specific parking analysis or other information to support approval of a parking reduction.
ii. Shared parking may be approved between any properties within or adjacent to the WMPO. Project sponsors must submit for city review and approval a written agreement between the parties documenting the amount, location, and term of the shared parking. If the shared parking agreement is terminated, additional parking must be provided and approved by the city within thirty days.
iii. The city may approve a shared parking reduction for on- or off-site parking based on a site-specific parking analysis demonstrating that the combined land uses can be accommodated with reduced off-street parking based on different peak periods of usage. There is no limit to the potential shared parking reduction.
iv. Parking Access. Where feasible, access to parking lots shall be from side streets and not directly from West Main Street or Catlin Street within the WMPO. Shared access to abutting properties is encouraged.
v. Parking shall be located behind the building. If not feasible to locate the parking behind the building the parking shall be located to the side of the building and shall not exceed the width of the street facing facade on West Main Street to ensure that the building remains the main component of the street frontage. Parking lots may front on side streets if located behind a building that fronts on West Main Street or Catlin Street within the WMPO.
vi. Existing parking deficits of legally established uses assigned to existing structures shall be allowed to continue even if a change of use occurs; provided, that in the judgment of the city the new use would not necessitate more parking spaces than the previous use.
vii. Parking Exceptions for Historic Structures. When a change in use within a historic structure would necessitate additional off-street parking, the additional off-street parking may be reduced or waived through administrative review. The applicant shall be required to show the need for a reduction or waiver and shall be the minimum necessary.
viii. New parking spaces will not be required for additions to existing buildings that are less than twenty-five percent of the existing floor area and less than one thousand square feet. This exception to the parking requirement may be utilized only once per property and does not apply to additions or remodeling for the purpose of adding residential units.
(Ord. 3889 § 3 (Exh. A), 2017. Formerly 17.22.190; Ord. 4009 § 1 (Exh. A), 2024)