The following are side sewer requirements:
EXHIBIT A
SIDE SEWER REQUIREMENTS
Six-inch sewer pipe required in street – two percent minimum grade construction in street must be done by a licensed side sewer contractor and requires a permit. Joints must be made with rubber gaskets.
Two percent grade (one-quarter-inch fall per foot). One hundred percent maximum grade (12 inches per foot) construction on property may be done by owner but requires an application with sketch of proposed sewer line. On approval, a permit will be issued provided all connection charges have been paid.
General Notes:
Legal description of lot must be provided. Dimensions A, B, C and D that show the size and location of house on lot must be known to obtain permit.
1. One-eighth bend and wye for extended connection.
2. Connection to main stack must be cast iron.
3. Outside house connection cast iron to clay four-inch to four-inch or two-inch to four-inch rubber adapter required.
4. Thirty-inch minimum distance from house.
5. Eighteen-inch minimum cover.
6. Thirty-inch minimum cover at property line.
7. Standard four-inch to six-inch increaser.
8. Four-inch inspection riser at property line – 12 inches minimum cover over top of riser.
9. Only city licensed and bonded side sewer contractors are permitted to operate in the district.
10. All 90-degree turns require a wye and one-eighth bend.
11. Lay pipe in straight line between bends. Make all changes in grade or line with one-eighth bends or wyes. No downspouts or outside drains allowed.
(Ord. 486 Exhibit A, 1971)