The following minimum standards apply to subdivision street paving:
(a)
Type.
Asphaltic or reinforced concrete surface with concrete curb and gutter.
(c)
Cross section.
A standard cross section for a residential street is shown in Figure I.[1] Cross sections for secondary and major streets shall be proportioned similarly. At intersections, curb return radius shall be twenty feet (20'); at cul-de-sacs, thirty-five feet (35').
[1]
Editor's note—Figure I is on file in the city offices.
(d)
Concrete.
(1)
Reinforcing steel.
a.
Material: Open hearth new billet steel.
b.
Yield strength: 60,000 pounds per square inch, minimum.
c.
Splices: 24 bar diameters.
d.
Bar size and spacing: No. three bars at eighteen-inch (18") centers, each way.
e.
Bar support: Metal or plastic "chairs" shall be used to hold bars in position during placement of concrete.
(3)
Cement.
Type I (Normal) Portland cement, or with City Engineer's approval, Type III (High Early Strength).
(4)
Aggregate.
Coarse and fine aggregate shall meet the requirements of Texas Highway Department Standard Specification "Item 360" for concrete pavement.
(6)
Curing.
Curing method shall retain at least ninety-seven (97) percent of moisture at twenty-four (24) hours, at least ninety-five (95) percent at three (3) days, and at least ninety-one (91) percent at seven (7) days. (American Society of Testing and Materials procedure C-5.)
(7)
Tests.
Flexural strength: Three (3) molds per two hundred (200) linear feet.
(8)
Placement.
Concrete shall not be placed on frozen subgrade; when air temperature is 38 degrees Fahrenheit or below; when air temperature is below 42 degrees Fahrenheit and declining; when finishing cannot be completed during natural daylight.
(e)
Asphaltic pavement.
(1)
Curb and gutter.
(3)
Surface course.
a.
Material:
Texas Highway Department Standard Specifications "Item 340" for Hot Mix Asphaltic Concrete Pavement, Type D, including a tack coat.
b.
Thickness: Two inches (2") after final compaction.
c.
Density: ninety-five (95) percent of the laboratory density obtained with the California Kneading Compactor per Test Method No. California 304 or equal test method approved by the City Engineer.
(f)
Subgrade.
(1)
Rolling machinery:
All subgrade shall be rolled.
(2)
Density required:
At least ninety (90) percent of maximum density (Modified Proctor Density Test: American Association State Highway Officials T99-49).
(3)
Lime stabilization:
Required when plasticity index (P.I.) of subgrade soil exceeds 18.0.
(4)
Cement stabilization:
Required when low plasticity index (P.I.) "spongy" or wet soils.
(5)
Subgrade shall not be allowed to dry before concrete or base is placed, nor shall concrete or base be placed on frozen subgrade.
(6)
Density tests:
At two hundred (200) linear feet intervals, or closer when requested by City Engineer.
Pavement Width | |
|---|---|
Thoroughfare Type | Minimum Sidewalk Width |
Thoroughfare | 48 feet |
Major Collector | 48 feet (additional 12' feet for turning lane) |
Minor Collector | 40 feet |
Local Street | 40 feet |