This chapter shall be known as the "landscape water use efficiency program."
(Ord. 375 § 1, 2009)
MAWA (in gallons) = (ETo)(0.62)[(0.7 x LA) + (0.3 x SLA)] | |
Where: | |
ETo | is historic local reference evapotranspiration |
LA | is total landscape area (including the SLA) in square feet |
SLA | is the amount of special landscape area in square feet |
EAWU (in gallons) = (ETo)(0.62) [((PF x HA)/IE) + SLA] | |
Where: | |
ETo | is reference evapotranspiration |
PF | is plant factor |
HA | is hydrozone area in square feet |
IE | is irrigation efficiency (minimum 0.71) |