[1]
For state law as to authority of town to regulate building construction, see WS, 1977, 15-1-103. For state law as to authority of town to adopt national building, etc., codes by reference, see WS, 1977, 15-1-119. For state law as to effect of additions or amendments by promulgating bodies, see WS, 1977, 15-1-119. For state law requiring filing of copy with clerk, see WS, 1977, 15-1-119.
(a) 
The following international codes, supplements, and amendments thereto are hereby adopted by reference as provided by W.S § 15-1-119 (Lexis/Nexis 2017 as amended), except those portions of such codes as amended, modified, added, or deleted below and the provisions thereof shall be controlling within the town.
(b) 
The following international codes, 2021 Editions, are hereby adopted by reference as if the same were fully set forth herein:
(1) 
2021 International Building Code.
a. 
Section 101.1. Insert: [Town of Wheatland].
b. 
Section 103.1. Insert: [Building Department].
c. 
Section 105.2. Building:
i. 
#2, #3, #8, #9, #11, #12. Delete in their entirety.
d. 
Section 105.2. Electrical:
i. 
#2. Delete in its entirety.
e. 
Section 420.4. First sentence to read: "Group R occupancies, not regulated under the provisions of the IRC, shall be equipped throughout with an automatic sprinkler system in accordance with Section 903.2.8."
f. 
Section 903.2.8. Sentence to read: "Excluding those regulated under the provisions of the IRC, an automatic sprinkler system installed in accordance with Section 903.3 shall be provided throughout all buildings with a Group R fire area."
g. 
Section 1612.3. Insert: [Town of Wheatland].
h. 
Section 1612.3. Insert: [April 16, 1979].
(2) 
2021 International Residential Code.
a. 
Section R101.1. Insert: [Town of Wheatland].
b. 
Section R105.2. Building:
i. 
#2. Delete in its entirety.
ii. 
#5. Sentence to read: "Sidewalks and driveways not more than 30 inches above adjacent grade and are not part of an accessible route."
iii. 
#7. Sentence to read: "Prefabricated swimming pools that are less than 24 inches deep, are not greater than 5,000 gallons and are installed entirely above ground."
c. 
Section R105.2. Electrical:
i. 
#4. Delete in its entirety.
d. 
Table R301.2. Climatic and Geographic Design Criteria.
THE TOWN OF WHEATLAND
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
BASED ON THE 2021 IRC
TABLE R301.2
GROUND SNOW LOAD
WIND DESIGN
SEISMIC DESIGN CATEGORY
SUBJECT TO DAMAGE FROM
WINTER DESIGN TEMP
ICE BARRIER UNDERLAY-MENT REQUIRED
FLOOD HAZARDS
AIR FREEZING INDEX
MEAN ANNUAL TEMP
Speed (mph)
Topographic effects
Special wind region
Wind-borne debris zone
Weathering
Frost line depth
Termite
25 LB
115
NO
NO
NO
B
SEVERE
42"
SLIGHT TO MODERATE
-3
YES
VARIES*
979
48.7
* Flood Hazards vary – Verify with the FEMA Flood Hazard Map (fema.gov).
 
e. 
Section R313. Is voluntary for automatic fire sprinkler systems.
f. 
Chapter 11. Is voluntary for energy efficiency with the minimum design requirements listed herein:
i. 
Fenestration U-factor – 0.32.
ii. 
Skylight U-factor – 0.55.
iii. 
Glazed Fenestration SHGC – 0.40.
iv. 
Ceiling R-value – 49.
v. 
Wood Frame Wall R-value – 20 or 13+5ci or 0+15ci.
vi. 
Floor R-value – 30.
vii. 
Basement Wall R-value – 19 or 15ci or 13+5ci.
viii. 
Crawl Space R-value – 19 or 15ci or 13+5ci.
• ci = continuous insulation
g. 
Section P2603.5.1. Insert in both locations: [42 inches].
h. 
Section P2904. Is voluntary for the design and installation of residential fire sprinkler systems.
(3) 
2021 International Existing Building Code.
a. 
Section 101.1. Insert: [Town of Wheatland].
b. 
Section 103.1. Insert: [Building Department].
c. 
Section 105.2. Building:
i. 
#3, #5. Delete in their entirety.
d. 
Section 105.2. Electrical:
i. 
#2. Delete in its entirety.
(4) 
2021 International Fire Code.
a. 
Section 101.1. Insert: [Town of Wheatland].
b. 
Section 103.1. Insert: [Building Department].
c. 
Section 112.4. Insert: [Misdemeanor, $750.00, 30 days].
d. 
Section 903.2.8. Sentence to read: "Excluding those regulated under the provisions of the IRC, an automatic sprinkler system installed in accordance with Section 903.3 shall be provided throughout all buildings with a Group R fire area."
(5) 
2021 International Mechanical Code.
a. 
Section 101.1. Insert: [Town of Wheatland].
b. 
Section 103.1. Insert: [Building Department].
c. 
Section 115.4. Insert: [Misdemeanor, $750.00, 30 days].
(6) 
2021 International Plumbing Code.
a. 
Section 101.1. Insert: [Town of Wheatland].
b. 
Section 103.1. Insert: [Building Department].
c. 
Section 115.4. Insert: [Misdemeanor, $750.00, 30 days].
d. 
Section 305.4.1. Insert in both locations: [42 inches].
e. 
Section 903.1.1. Insert: [18 inches].
(7) 
2021 International Fuel Gas Code.
a. 
Section 101.1. Insert: [Town of Wheatland].
b. 
Section 115.4. Insert: [Misdemeanor, $750.00, 30 days].
(c) 
All permit fees are those fees set forth in the Wheatland building permit fee schedule.
(d) 
The town does hereby establish and create a fire district as required by the codes adopted herein. The fire district boundaries are shown on a map, a copy which is available to the public at the Wheatland Town Hall. The fire district map shall be marked as "Fire District Map, Ordinance No. 712."
(e) 
Wyoming Outdoor Advertising Act, specifically excluding WS, 1977, 24-10-106(j)(i) and (ii), 24-10-107(c) and (3), 24-10-110; amending § 24-10-103(a)(iv) to read as follows:
"Commission" means the Planning and Zoning Commission for the Town of Wheatland; and amending § 24-10-107(a) and 24-10-109(b) to replace the word "commission" with "Town of Wheatland Building Inspector".
(f) 
Wyoming State Highway Department rules and regulations entitled Outdoor Advertising, Chapter XVI, adopted in accordance with WS, 1977, 24-10-105, as amended, dated December 27, 1985; amending Section 2(c) to read as follows:
"Commission" means the Planning and Zoning Commission for the Town of Wheatland";
(g) 
Subsections (d) and (e) of this section shall apply to the area within the town of Wheatland town limits, which is within 500 feet of Interstate 25.
(1996 Code § 7-107; Ord. 608, 1992; Ord. 757, 2011; Ord. 768, 2012; Ord. 779, 2014; Ord. 784, 2015; Ord. 816, 2018; Ord. 827, 2020; Ord. 837, 2022)
At least one copy of each code adopted by WMC § 15.05.010 and any ordinance providing for amendments, modifications, additions or deletions in such codes adopted by the town council shall be maintained on file in the office of the town clerk where they shall be available for public inspection during the normal office hours of the town clerk. One copy of each ordinance amending or modifying such code shall be kept with each copy of such code and made available for public inspection at the same time as and in the same manner as such code.
(1996 Code § 7-108; Ord. 462 § 2, 1977; Ord. 635 § 3, 1995)
(a) 
In addition to the smoke detectors required by the Uniform Building Code as adopted by the town of Wheatland, an additional smoke detector shall be placed in each furnace room, or if the furnace is not located in a separate room, then the smoke detector will be adjacent to the furnace location.
(b) 
The smoke detector shall be operated by electricity, with a battery backup.
(c) 
This additional smoke detector shall be required for all new construction, and shall apply to any and all remodeling that exceeds $1,000.
(Ord. 674 §§ 1 – 3, 1999)
Unless specifically defined below, words or phrases used in this chapter shall be interpreted so as to give them the meaning they have in common usage and to give this chapter its most reasonable application.
"Appeal"
means a request for a review of the building inspector's interpretation of any provisions of this chapter or a request for a variance.
"Area of special flood hazard"
means the land in the floodplain within a community subject to a one percent or greater chance of flooding in any given year.
"Base flood"
means the flood having a one percent chance of being equaled or exceeded in any given year.
"Development"
means any manmade change to improved or unimproved real estate, including but not limited to buildings or other structures, mining, dredging, filling, grading, paving, excavation or drilling operations located within the area of the special flood hazard.
"Existing manufactured home park or subdivision"
means a manufactured home park for which the construction of facilities for servicing the lot on which the manufactured homes are to be affixed (including, at a minimum, the installation of utilities, either final site grading or the pouring of concrete pads, and the construction of streets) are completed before the effective date of the ordinance codified in this section.
"Expansion to an existing manufactured home park or subdivision"
means the preparation of additional sites by the construction of facilities for servicing the lots on which the manufactured homes are to be affixed (including the installation of utilities, either final site grading or pouring of concrete pads, or the construction of streets).
"Flood" or "flooding"
means a general and temporary condition of partial or complete inundation of normally dry land areas from:
(1) 
The overflow of inland or tidal waters; and/or
(2) 
The unusual and rapid accumulation or runoff of surface waters from any source.
"Flood Insurance Rate Map (FIRM)"
means the official map on which the Federal Emergency Management Agency has delineated both the areas of special flood hazards and the risk premium zones applicable to the community.
"Flood Insurance Study"
means the official report provided by the Federal Emergency Management Agency that includes flood profiles, the Flood Boundary-Floodway Map and the water surface elevation of the base flood.
"Floodway"
means the channel of a river or other watercourse and the adjacent land areas that must be reserved in order to discharge the base flood without cumulatively increasing the water surface elevation more than one foot.
"Lowest floor"
means the lowest floor of the lowest enclosed area (including basement). An unfinished or flood resistant enclosure, usable solely for parking of vehicles, building access or storage, in an area other than a basement area, is not considered a building's lowest floor; provided, that such enclosure is not built so as to render the structure in violation of the applicable nonelevation design requirements of this chapter.
"Manufactured home"
means a structure, transportable in one or more sections, which is built on a permanent chassis and is designed for use with or without a permanent foundation when attached to the required utilities. The term "manufactured home" does not include a "recreational vehicle."
"New manufactured home park or subdivision"
means a manufactured home park or subdivision for which the construction of facilities for servicing the lots on which the manufactured homes are to be affixed (including at a minimum, the installation of utilities, the construction of streets, and either final site grading or the pouring of concrete pads) is completed on or after the effective date of floodplain management regulations adopted by a community.
"New construction"
means structures for which the "start of construction" commenced on or after the effective date of the ordinance codified in this section.
"Recreational vehicle"
means a vehicle which is:
(1) 
Built on a single chassis;
(2) 
Four hundred square feet or less when measured at the largest horizontal projections;
(3) 
Designed to be self-propelled or permanently towable by a light duty truck; and
(4) 
Designed primarily not for use as a permanent dwelling but as temporary living quarters for recreational, camping, travel or seasonal use.
"Start of construction"
includes substantial improvement, and means the date the building permit was issued, provided the actual start of construction, repair, reconstruction, placement or other improvement was within 180 days of the permit date. The "actual start" means the first placement of permanent construction of a structure on a site, such as the pouring of slab or footings, the installation of piles, the construction of columns, or any work beyond the stage of excavation or the placement of a manufactured home on a foundation. Permanent construction does not include land preparation, such as clearing, grading, and filling; nor does it include the installation of streets and/or walkways; nor does it include excavation for a basement, footings, piers, or foundations or the erection of temporary forms; nor does it include the installation on the property of accessory buildings, such as garages or sheds not occupied as dwelling units or not part of the main structure.
"Structure"
means a walled and roofed building or manufactured home that is principally above ground.
"Substantial damage"
means damage of any origin sustained by a structure whereby the cost of restoring the structure to its before-damaged condition would equal or exceed 50 percent of the market value of the structure before the damage occurred.
"Substantial improvement"
means any reconstruction, rehabilitation, addition or other improvement of a structure, the cost of which equals or exceeds 50 percent of the market value of the structure before the "start of construction" of the improvement. This term includes structures which have incurred "substantial damage," regardless of the actual repair work performed. The term does not, however, include either:
(1) 
Any project for improvement of a structure to correct existing violation of state or local health, sanitary or safety code specifications which have been identified by the local code enforcement official and which are the minimum necessary to assure safe living conditions; or
(2) 
Any alteration of a "historic structure"; provided, that the structure's continued designation as a "historic structure."
"Variance"
means a grant of relief from the requirements of this chapter which permits construction in a manner that would otherwise be prohibited by this chapter.
(1996 Code § 8A-l; Ord. 592, 1989)
The areas of special flood hazard identified by the Federal Emergency Management Agency in a scientific and engineering report entitled, "The Flood Insurance Study for the town of Wheatland," dated October 1978, with an accompanying Flood Insurance Rate Map (FIRM), are hereby adopted by reference and declared to be a part of this chapter. The Flood Insurance Study and FIRM are on file at the office of the building inspector located in the City Hall, Wheatland, Wyoming.
(1996 Code § 8A-3)
No structure or land shall hereafter be constructed, located, extended, converted or altered without full compliance with the terms of this chapter and other applicable regulations.
(1996 Code § 8A-4)
This chapter is not intended to repeal, abrogate, or impair any existing easements, covenants, or deed restrictions. However, where this chapter and another chapter, ordinance, easement, covenant or deed restriction conflict or overlap, whichever imposes the more stringent restrictions shall prevail.
(1996 Code § 8A-5)
The degree of flood protection required by this chapter is considered reasonable for regulatory purposes and is based on scientific and engineering considerations. Larger floods can and will occur on rare occasions. Flood heights may be increased by manmade or natural causes. This chapter does not imply that land outside the areas of special flood hazard or uses permitted within such areas will be free from flooding or flood damages. This chapter shall not create liability on the part of the town of Wheatland, any officer or employee thereof, or the Federal Emergency Management Agency for any flood damages that result from reliance on this chapter or any administrative decision lawfully made thereunder.
(1996 Code § 8A-7)
A development permit shall be obtained before construction or development begins within any area of special flood hazard established in WMC § 15.10.030. Application for a development permit shall be made on forms furnished by the building inspector and may include, but not be limited to:
Plans in duplicate drawn to scale showing the nature, location, dimensions and elevations of the area in question; existing or proposed structures, fill, storage of materials, drainage facilities, and the location of the foregoing. Specifically, the following information is required:
(a) 
Elevation in relation to mean sea level of the lowest floor (including basement) of all structures;
(b) 
Elevation in relation to mean sea level to which any structure has been floodproofed;
(c) 
Certification by a registered professional engineer or architect that the floodproofing methods for any nonresidential structure meet the floodproofing criteria in WMC § 15.10.130(b); and
(d) 
Description of the extent to which any watercourse will be altered or relocated as a result of proposed development.
(1996 Code § 8A-8)
(a) 
Duties of the building inspector shall include, but not be limited to:
(1) 
Review all development permits to determine that the permit requirements of this chapter have been satisfied.
(2) 
Review all development permits to determine that all necessary permits have been obtained from federal, state or local governmental agencies from which prior approval is required.
(3) 
Review all development permits to determine if the proposed development is located in the floodway. If located in the floodway, assure that the encroachment provisions of WMC § 15.10.140(a) are met.
(b) 
Use of Other Base Flood Data. When base flood elevation data has not been provided in accordance with WMC § 15.10.030, the building inspector shall obtain, review and reasonably utilize any base flood elevation and floodway data available from any federal, state or other source as criteria for requiring that new construction, substantial improvements or other development in Zone A are administered in accordance with WMC § 15.10.130.
(c) 
Information to Be Obtained and Maintained.
(1) 
Obtain and record the actual elevation (in relation to mean sea level) of the lowest floor (including basement) of all new or substantially improved structures, and whether or not the structure contains a basement.
(2) 
For all new or substantially improved floodproofed structures:
a. 
Verify and record the actual elevation (in relation to mean sea level) to which the structure has been floodproofed.
b. 
Maintain the floodproofing certifications required in WMC § 15.10.080(c).
c. 
Maintain for public inspection all records pertaining to the provisions of this chapter.
(d) 
Alteration of Watercourses.
(1) 
Notify adjacent communities and the appropriate state and federal agencies prior to any alteration or relocation of a watercourse, and submit evidence of such notification to the Federal Emergency Management Agency.
(2) 
Require that maintenance is provided within the altered or relocated portion of said watercourse so that the flood-carrying capacity is not diminished.
(e) 
Interpretation of FIRM Boundaries. Make interpretations, where needed, as to the exact location of the boundaries of the areas of special flood hazard (for example, where there appears to be a conflict between a mapped boundary and actual field conditions). The person contesting the location of the boundary shall be given a reasonable opportunity to appeal the interpretation as provided in WMC § 15.10.110.
(1996 Code § 8A-10)
(a) 
Appeal Board.
(1) 
The board of adjustment, as established by the town of Wheatland, shall hear and decide appeals and request for variances from the requirements of this chapter.
(2) 
The board of adjustment shall hear and decide appeals when it is alleged there is an error in any requirement, decision or determination made by the building inspector in the enforcement or administration of this chapter.
(3) 
Those aggrieved by the decision of the board of adjustment or any taxpayer may appeal such decisions to the District Court, Eighth Judicial, Platte County, Wyoming, as provided by state law.
(4) 
In passing upon such applications, the board of adjustment shall consider all technical evaluations, all relevant factors, standards specified in other sections of this chapter, and:
a. 
The danger that materials may be swept onto other lands to the injury of others;
b. 
The danger to life and property due to flooding or erosion damages;
c. 
The susceptibility of the proposed facility and its contents to flood damage and the effect of such damage on the individual owners;
d. 
The importance of the services provided by the proposed facility to the community;
e. 
The necessity to the facility of a waterfront location, where applicable;
f. 
The availability of alternative locations for the proposed use which are not subject to flooding or erosion damage;
g. 
The compatibility of the proposed use with the existing and anticipated development;
h. 
The relationship of the proposed use to the comprehensive plan and floodplain management program for that area;
i. 
The safety of access to the property in times of flood for ordinary and emergency vehicles;
j. 
The expected heights, velocity, duration, rate of rise and sediment transport of the flood waters and the effects of wave action, if applicable, expected at the site; and
k. 
The costs of providing governmental services during and after flood conditions, including maintenance and repair of public utilities and facilities such as sewer, gas, electrical, and water systems, streets and bridges.
(5) 
Upon consideration of the factors of subsection (a)(4) of this section and the purposes of this chapter, the board of adjustment may attach such conditions to the granting of variances as it deems necessary to further the purposes of this chapter.
(6) 
The building inspector shall maintain the records of all appeal actions, including technical information, and report any variances to the Federal Emergency Management Agency.
(b) 
Conditions for Variances.
(1) 
Generally, variances may be issued for new construction and substantial improvements to be erected on a lot of one-half acre or less in size contiguous to and surrounded by lots with existing structures constructed below the base level, providing subsections (a)(4)(a) through (k) of this section have been fully considered. As the lot size increases beyond the one-half acre, the technical justifications required for issuing the variance increases.
(2) 
Variances may be issued for the reconstruction, rehabilitation or restoration of structures listed on the National Register of Historic Places or the State Inventory of Historic Places without regard to the procedures set forth in the remainder of this section.
(3) 
Variances shall not be issued within any designated floodway if any increase in flood levels during the base flood discharge would result.
(4) 
Variances shall only be issued upon a determination that the variance is the minimum necessary, considering the flood hazard, to afford relief.
(5) 
Variances shall only be issued upon:
a. 
A showing of good and sufficient cause;
b. 
A determination that failure to grant the variance would result in exceptional hardship to the applicant; and
c. 
A determination that the granting of a variance will not result in increased flood heights, additional threats to public safety, extraordinary public expense, create nuisances, cause fraud on or victimization of the public as identified in subsection (a)(4) of this section or conflict with existing local laws or chapters.
(6) 
Any applicant to whom a variance is granted shall be given written notice that the structure will be permitted to be built with a lowest floor below the base flood elevation and that the cost of flood insurance will be commensurate with the increased risk from the reduced lowest floor elevation.
(1996 Code § 8A-11)
In all areas of special flood hazards, the following standards are required:
(a) 
Anchoring.
(1) 
All new construction and substantial improvements shall be anchored to prevent flotation, collapse, or lateral movement of the structure and capable of resisting the hydrostatic and hydrodynamic loads.
(2) 
All manufactured homes must be elevated and anchored to resist flotation, collapse or lateral movement and capable of resisting the hydrostatic and hydrodynamic loads. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This requirement is an addition to applicable state and local anchoring requirements for resisting wind forces. Specific requirements may be:
a. 
Over-the-top ties be provided at each of the four corners of the manufactured home, with two additional ties per side at intermediate locations, with manufactured homes less than 50 feet long requiring one additional tie per side;
b. 
Frame ties be provided at each corner of the home with five additional ties per side at intermediate points, with manufactured homes less than 50 feet long requiring four additional ties per side;
c. 
All components of the anchoring system be capable of carrying a force of 4,800 pounds; and
d. 
Any additions to the manufactured home be similarly anchored.
(b) 
Construction Materials and Methods.
(1) 
All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage.
(2) 
All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage.
(3) 
All new construction and substantial improvements shall be constructed with electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding.
(c) 
Utilities.
(1) 
All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system;
(2) 
New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the systems and discharge from the systems into flood waters; and
(3) 
On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding.
(d) 
Subdivision Proposals.
(1) 
All subdivision proposals shall be consistent with the need to minimize flood damage;
(2) 
All subdivision proposals shall have public utilities and facilities such as sewer, gas, electrical and water systems located and constructed to minimize flood damage;
(3) 
All subdivision proposals shall have adequate drainage provided to reduce exposure to flood damage; and
(4) 
Base flood elevation data shall be provided for subdivision proposals and other proposed development which contain at least 50 lots or four acres (whichever is less).
(1996 Code § 8A-12)
In all areas of special flood hazards where base flood elevation data has been provided as set forth in WMC § 15.10.030, Basis for establishing the areas of special flood hazard, or WMC § 15.10.100(b), Use of Other Base Flood Data, the following provisions are required:
(a) 
Residential Construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement) elevated to or above the base flood elevation.
(b) 
Nonresidential Construction. New construction and substantial improvement of any commercial, industrial or other nonresidential structure shall either have the lowest floor (including basement) elevated to the level of the base flood elevation; or, together with attendant utility and sanitary facilities, shall:
(1) 
Be floodproofed so that below the base flood elevation the structure is watertight with walls substantially impermeable to the passage of water;
(2) 
Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and
(3) 
Be certified by a registered professional engineer or architect that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions of this subsection. Such certifications shall be provided to the official as set forth in WMC § 15.10.100(c)(2).
(c) 
Manufactured homes to be placed on a single lot or in a new or expansion to an existing manufactured home park or subdivision or in an existing manufactured home park or subdivision on which a manufactured home has incurred substantial damage as a result of a flood:
(1) 
It is required that manufactured homes that are placed or substantially improved within Zones A1-30, AH and AE on the community's FIRM on sites:
a. 
Outside of a manufactured home park or subdivision,
b. 
In a new manufactured home park or subdivision,
c. 
In an expansion to an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as the result of a flood, be elevated on a permanent foundation such that the lowest floor of the manufactured home is elevated to or above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement.
(d) 
Manufactured homes to be placed in an existing manufactured home park or subdivision in which a manufactured home has not incurred substantial damage as a result of a flood:
(1) 
It is required that manufactured homes to be placed or substantially improved on sites in an existing manufactured home park or subdivision within Zones A1-30, AH, and AE on the community's FIRM that are not subject to the provision of subsection (c) of this section be elevated so that either:
a. 
The lowest floor of the manufactured home is at or above the base flood elevation, or
b. 
The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than 36 inches in height above grade and is securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement.
(1996 Code § 8A-13)
Located within areas of special flood hazard established in WMC § 15.10.030 are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of flood waters which carry debris, potential projectiles and erosion potential, the following provisions apply:
(a) 
Prohibit encroachments, including fill, new construction, substantial improvements, and other development unless certification by a registered professional engineer or architect is provided demonstrating that encroachments shall not result in any increase in flood levels during the occurrence of the base flood discharge.
(b) 
If subsection (a) of this section is satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of this section, provisions for flood hazard reduction.
(1996 Code § 8A-14)
[1]
Editor's Note: Ordinance No. 600, passed on third and final reading August 13, 1990, which made minor amendments to Ordinance No. 592, passed on third and final reading on May 22, 1989. Ordinance No. 592 repealed Ordinance No. 495, which was set forth in Chapter 8(a) of the Wheatland Town Code supplemented in 8/84.