(1) 
Construction, installation and maintenance of equipment and fixtures. All required equipment and fixtures in every structure shall be constructed, installed and maintained to properly and safely perform their intended functions in accordance with the provisions of the Building, Electrical and Plumbing Codes.
(2) 
Maintained clean and sanitary. All equipment and fixtures shall be maintained in a clean and sanitary condition by the occupant so as not to breed insects or rodents or produce dangerous or offensive gases or odors.
(3) 
Plumbing fixtures. Water lines, plumbing fixtures, vents and drains shall be properly installed, connected, and maintained in working order and shall be kept free from obstructions, leaks, and defects and be capable of performing the function for which they are designed. All repairs and installations shall be made in accordance with all applicable building or plumbing codes.
(4) 
Plumbing system. Every plumbing stack, waste, and sewer line shall be installed and maintained to function properly and shall be kept free from obstructions, leaks, and defects to prevent structural deterioration or health hazards. All repairs and installations shall be made in accordance with the provisions of all applicable building or plumbing codes.
(5) 
Cooking and heating equipment. Each space heating, cooking, and water heating device located in a building or structure shall be properly installed, connected, and maintained and shall be capable of performing the function for which it was designed in accordance with the provisions of all applicable building codes.
(6) 
Electrical outlets and fixtures. Every electrical outlet and fixture shall be installed, maintained, and connected to the source of electric power in accordance with all applicable building and electrical codes.
(7) 
Electrical system. Every room of every dwelling unit and all public and common areas shall be supplied with electric service, over current protection devices, electric outlets, and electric fixtures which are properly installed in compliance with the National Electrical Code. All electrical equipment shall be maintained in a safe working condition and shall be energized by an approved source of electric power and in compliance with the applicable ordinances and codes of the Village and the state. All branch circuits shall have sufficient capacity to safely serve the normally anticipated loads resulting from everyday living. When the Building Inspector determines the electrical system in a building constitutes a hazard to the occupants of the building by reason of inadequate service, improper fusing, insufficient outlets, improper wiring, improper installation, deterioration or damage, or other reasons, he or she shall require the defects to be corrected to eliminate the hazard.