For the purpose of this chapter, the following terms shall have the meanings indicated in this article:
The individual, inspector, official, board, department or agency authorized to administer and enforce the provisions of this Plumbing Code as adopted or amended.
In a water supply system, the unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank or plumbing fixture and the flood level rim of the receptacle.
Accepted or acceptable under an applicable specification stated or cited in this chapter, or accepted as suitable for the proposed use under procedures and powers of administration delegated in this chapter.
A drain installed to collect surface or rain water from an open area.
The flow of water or other liquids into the distributing pipes of a potable supply of water from any source or sources other than its intended source. Back-siphonage is one type of backflow and a flow through a cross-connection is another.
Any arrangement whereby backflow can occur; but the term "backflow connection" is the one used in this chapter for the condition as defined.
A "branch" line is any part of a piping system other than a main.
A length of soil or waste stack corresponding in general to a story height, but in no case less than eight feet, within which the horizontal branches from one floor or story of the building are connected to the stack.
A vent connecting one or more individual vents with a vent stack or stack vent.
An enclosed structure having exterior or party walls and a roof, designed for the shelter of persons, animals or property.
That part of the lowest horizontal piping of a drainage system which receives the discharge from soil, waste and other drainage pipes inside the walls of any building and conveys the same to the building (or house) sewer beginning five feet outside of the building wall of the structure.
That part of the horizontal piping of a drainage system which extends from the end of the building drain five feet outside of the building wall or other extension and which receives the discharge of the building drain and conveys it to the public sewer or other point of disposal, and conveying the drainage of but one building site.
A building drain used for conveying rainwater, groundwater, subsurface water, cooling water or similar discharge to a building storm sewer or to a combined building drain or sewer, extending to a point not less than five feet outside the building wall.
The pipe extending from the building storm drain to the public storm sewer or other place of disposal.
That portion of a drainage system which cannot drain by gravity into the building sewer.
A branch vent that functions for two or more traps and extends from in front of the last fixture connection of a horizontal branch to the vent stack by means of which siphonage and back pressure on trap seals are prevented by running two separate ventilating pipes which are placed at opposite sides of the room and the fixtures placed between the two pipes and can be used on one or more floors.
A trade term designating an integral combination of one sink and one or two laundry tubs in one fixture.
A sewer that receives both stormwater and sewage.
A vent pipe extending vertically above the soil or waste branch.
A waste pipe from two or more fixtures connected to a single trap.
A connection through which a supply of potable water could be contaminated, polluted or infected.
A branch leading from a soil, waste or vent pipe, building drain or building sewer, which is terminated at a developed distance of two feet or more by means of a cap, plug or other closed fittings not used for admitting liquids into the pipe.
Of a line of pipe is its length along the center line of the pipe and fittings.
Unless specifically stated, the nominal diameter of a pipe as designated commercially.
A water conductor from the roof to the building storm drain or other means of disposal.
Any pipe which carries waste or waterborne wastes into a building drain system.
All piping within public or private premises which conveys sewage, rainwater or other liquid wastes, and includes the building sewer to a legal point of disposal, but shall not include the mains of the public sewer system or a public sewage treatment or disposal plant.
A vent connection at the junction of two fixture drains serving as an individual vent for both fixtures.
An installation in its entirety above ground and composed of galvanized wrought-iron or galvanized steel pipe screwed into recessed drainage fittings.
The water supply pipe between the fixture supply pipe and the water distributing pipe.
The drain from the trap of the fixture to the junction of that drain with any other drainpipe.
A design factor for drainage piping so chosen that the load-producing value of the plumbing fixtures can be expressed approximately as multiples of that factor. For the purpose of this chapter, this value is assumed to be 7.5 gpm, or 7 1/2 gallons per minute.
In reference to a plumbing fixture, the level at which water begins to overflow the top or rim of the fixture.
A valve for flushing water closets and similar fixtures.
A closet that has no water in the bowl and has the trap and control valve for its water supply below the frost line.
Of a line of pipe is its slope in reference to a horizontal plane. In plumbing it is usually expressed as the fall in inches per foot of length of pipe.
A receptacle to collect and retain grease and fatty substances normally found in kitchen or similar wastes. It is installed in the drainage system between the kitchen or other point of production of the waste and the building sewer.
A branch drain extending laterally from a soil or waste stack or building drain, with or without vertical sections or branches, which receives the discharge from one or more fixture drains and conducts it to the soil or waste stack or to the building (house) drain.
A pipe which does not connect directly with the drainage system but discharges into it through a properly trapped fixture or receptacle.
A pipe installed to vent a trap, soil or waste pipe underneath or back of fixture it serves and connected to a point above the fixture to the general vent system (sometimes referred to as a "back vent").
A person who through training and experience has acquired the skill and knowledge necessary for the proper installation of plumbing.
A water conductor from the roof to the building storm drain or other means of disposal.
A metal duct through which vapors of foul air are removed from room or fixtures.
The same as a circuit vent except that it loops back and connects with the soil, waste or stack vent instead of the vent stack by means of which siphonage and back pressure on the seals of traps are prevented by running two separate ventilating pipes, the fixtures being placed between two such pipes and the loop or yoke vent pipe being carried over fixtures back to the main vent. This system can be used on only one floor.
The main of any system of continuous piping is the principal artery of the system on which branches may be connected.
The main sewer or public sewer in the street, alley or other premises under the jurisdiction of the City of Hudson and the Department of Public Works.
[Amended 12-12-1973]
A person who holds a master plumber's certificate of competency obtained after having successfully passed an examination given by the Examining Board of Plumbers of the City of Hudson.
Includes not only an individual, male or female, but also includes any firm, corporation or association of individuals holding or applying for a master plumber's certificate.
Within buildings, the installation and relocation of the pipes, fixtures and other apparatus for bringing in and distributing the water supply, removing the liquids and waterborne wastes and removing rainwater and liquid drainage.
Receptacles which receive water, liquid or waterborne wastes and discharge them into a drainage system with which they are directly or indirectly connected.
When applied to a building, includes the water supply distributing pipes, the fixtures and fixture traps, the soil, waste and vent pipes, the building (house) drain and building (house) sewer and stormwater system, with their devices, appurtenances and connections within the building and adjacent premises, except that term shall not include the hot water distributing piping of a hot water heating system or connection between various pieces of a boiler plant, engine room machines, air-conditioning and refrigerating system, but such term shall include the primary water supply to any of the excepted systems or equipment and the main drains or wastes from such excepted systems or equipment.
Water from a public or private water supply system or source which is accepted by the proper governing authority as suitable for human consumption.
A sewer constructed or operated by the City.
A master plumber who holds a certificate of competency issued by the Examining Board of Plumbers of the City of Hudson and who performs or intends to perform plumbing work in the City of Hudson on his own account or as a bona fide member of a firm or corporation under the provisions of § 45-a of the General City Law, and has his name and metal sign conspicuously displayed at his place of business in the City of Hudson or at the site where such plumbing work is being performed. If a registered master plumber has no established place of business, he shall display his name and metal sign at the site where such plumbing work is being performed. If the registered master plumber has two or more plumbing jobs at the same time, his name and metal sign at one job will be deemed sufficient.
A mechanical device used to relieve excessive pressure or vacuum.
A branch from the vent stack, connected to a horizontal branch between the first fixture branch and the soil or waste stack, whose primary function is to provide a circulation of air between the vent stack and the soil or waste stack.
A drain installed to receive water collected on the surface of a roof and to discharge it into the leader (downspout).
A sewer which carries sewage and excludes storm, surface and ground water.
A device to receive sewage and reduce the solid matter contained in the sewage to a liquid form.
Any liquid waste containing animal or vegetable matter in suspension or solution, and may include liquids from laboratories or industrial institutions containing minerals in solution.
A device for raising sewage or waste matter from a lower to a higher level.
The word "shall" is a mandatory term.
Any pipe which conveys the discharge of water closets or fixtures having similar functions, with or without the discharge from other fixtures, to the house drain.
A general term for the vertical main of a system of soil, waste or vent piping.
The extension of soil or waste stack above the highest horizontal branch to be connected to the stack.
A drain used for conveying rainwater, subsurface water, condensate, cooling water or other similar discharges.
A sewer which carries off surface or stormwater from streets, roofs or other areas, including street wash but not including sewage or liquid industrial waste.
A drain installed for collecting subsurface or seepage water and conveying it to a place of disposal.
A tank or a pit which receives the discharge from the subdrains and other wastes, located below the normal grade of the gravity system, and from which the discharge is pumped or ejected into a drainage system.
Devices for securing stacks, pipes and fixtures, respectively, to walls, ceilings or floors.
A fitting or device so designed and constructed as to provide a liquid seal which will prevent the back passage of air without materially affecting the flow of sewage or waste water through it.
The vertical distance between the crown wier and dip of the trap.
When applied to plumbing material, fixtures or equipment, means previous installation and removal.
A vertical pipe installed primarily for the purpose of providing a circulation of air to and from any part of the drainage system (sometimes called a "main vent").
A pipe or pipes installed to provide a flow of air to or from a drainage system or to provide a circulation of air within such system to protect the trap seals from siphonage or back pressure.
A pipe that receives the discharge from any fixture, except water closets or similar fixtures, and conveys the same to the building drain, soil or waste stack.
A pipe in a building which conveys water from the water service pipe to the plumbing fixtures and other outlets in any part of the premises.
A water supply pipe for public or community use.
The pipe from the water main or other source of supply to the building served.
Consists of the water service, curb box and curb stop, the water distributing pipes and the necessary connecting pipes, fittings, control valves and all appurtenances in or adjacent to the building.
A soil or waste pipe that serves also as a vent.