The subdivider, before the approval of the subdivision plat, shall complete all improvements to the satisfaction of the Village Engineer or post a performance bond sufficient to ensure the satisfactory completion of the following required improvements, except where waivers may be requested and the Village Board may waive, subject to appropriate conditions, those improvements as it considers are not requisite in the interest of public health, safety and general welfare.
A. 
Streets. All streets shall be constructed, graded and paved in accordance with the standards and specifications on file in the Village Clerk's office and such other specifications as the Village Board or Village Engineer may require.
B. 
Storm drains, culverts, catch basins and other drainage structures. All storm drains, culverts, catch basins and other drainage structures shall be installed in accordance with the standards and specifications on file in the Village Clerk's office and in accord with the final map approved by the Village Board. All pipe shall comply with the requirements of the current New York State Department of Transportation specifications governing construction of these facilities. The location, length, depth, size, grade and type of pipe shall be designated in the plans. If unusual conditions are discovered at the time of construction, which are not provided for in the plans, the Village Engineer shall determine the type and extent of construction required to overcome such conditions.
C. 
Curbing. Curbing shall be constructed on all streets shown on all proposed subdivision plats and in accordance with the construction standards on file in the Village Clerk's office.
D. 
Sidewalks. All sidewalks shall be required and constructed in accord with the standards, if any, on file in the Village Clerk's office.
E. 
Driveway aprons. All driveway aprons shall be required between the curbing and the sidewalk and shall be constructed in accordance with standards, if any, on file in the Village Clerk's office.
F. 
Street signs. All street signs shall be of metal and shall be installed at the intersection of all streets in conformity with Village specifications, if any, at the locations approved by the Village Board.
G. 
Grass strips. All grass strips shall be provided within the portion of the street right-of-way beyond the curbline and shall be properly graded and seeded.
H. 
Street trees. All street trees shall be planted in every subdivision at intervals from 40 feet to 60 feet along both sides of the street. Existing trees may be taken into consideration when determining the above. Trees shall be at least three feet from any sidewalk and located on the building side of the walk rather than the street side, wherever practicable. Where dwelling structures are oriented with their rear on the street, street trees shall be at least six feet from the curbline. Trees should also be at least 10 feet from any utility line. The average trunk diameter shall be at least two inches and an average height of six feet above finished grade level is required. Such trees shall be of a species and at locations approved by the Village Board. No tree shall be planted within 25 feet from an existing or proposed street light or street intersection.
I. 
Shade trees. All shade trees, other than within the right-of-way, may be required when, taking into consideration the existing trees on the lots, the Village Board shall deem it necessary. The trees shall be in conformance with the standards of size, kind and locational limitations prescribed for trees along the street line.
J. 
Street lighting facilities. All street lighting facilities shall be provided along all streets in the subdivision and along all streets upon which the subdivision abuts. Such lighting facilities shall be in accordance with the Village standards, if any, and shall be installed as approved and directed by the Village Engineer.
K. 
Sanitary sewers and treatment disposal facilities shall be required. Where a public sanitary sewer is reasonably accessible, the subdivider shall connect or provide for connection with such sanitary sewer and shall provide within the subdivision the sanitary sewer system required to make the sewer accessible to each lot in the subdivision. Sewer systems shall be approved by the Village and Onondaga County and be in accordance with other requirements of law. The construction is subject to the supervision of the Village Engineer.
L. 
Public water main. Where a public water main is within 500 feet, the subdivider shall connect with such water main and provide a water connection for each lot in accordance with Village standards, if any, procedures and supervision. Fire hydrants shall be required and shall be installed in the locations approved by the Village Engineer and in accordance with the New York State Board of Fire Underwriters.
M. 
Permanent monuments. All permanent monuments shall be set at block corners and at intervals of approximately 500 feet, or such other distance as the Village Board may determine appropriate, and their location shall be shown on the subdivision plat. Iron pipes shall not be considered permanent monuments for the purpose of these regulations.
N. 
All utilities to be underground. All utilities within the subdivision shall be placed underground. The Village Board may require that underground utilities be placed in the street right-of-way between the paved roadway and street line to simplify location and repair of lines when they require attention. The subdivider shall install underground service connections to the property line of each lot within the subdivision for such required utilities before the street is paved.