[Amended 9-22-1987 by Ord. No. 87-54; 11-29-2005 by Ord. No. 05-60A; 4-25-2006 by Ord. No. 06-17; 7-10-2007 by Ord. No. 07-35; 2-7-2023 by Ord. No. O-22-23]
A. For one- and two-family dwellings and all other permitted buildings, except townhouses and new multifamily dwellings, and for all conditional uses when a new building or enlargement of an existing building is proposed, the bulk requirements shall be as specified as for the R-1 Zone in §
347-45.
B. For new multifamily dwellings, the following requirements shall apply:
(1) Maximum building height and number of stories.
(a) The maximum building height shall be 40 feet. No dwellings or parts of dwellings, except for storage and utilities areas, shall be located more than two feet below the adjoining general grade level, with light wells not counted as part of the adjoining grade level.
(b) Maximum number of stories: 2 1/2.
(2) The minimum front yard setback shall be 40 feet, except that where the average setback of existing buildings within 200 feet and within the same block front and zone is less than 40 feet, the average setback so determined shall apply, down to a minimum of 30 feet. A corner lot and through lot shall provide such required minimum front yard for each street frontage.
(3) The minimum side yard setback shall be 18 feet, except that where buildings extend for a length of more than 80 feet along the side line, section or sections over 80 feet in length shall have a minimum setback of 30 feet, and if there is more than one building section with a length of up to 80 feet with a minimum setback, these sections shall be separated by a distance of at least 50 feet.
(4) The minimum rear yard setback shall be 40 feet.
(5) The principal building or buildings shall not occupy more than 20% of the ground area of the site, and the maximum impervious coverage shall not exceed 65% of the ground area of the site.
(6) No principal building shall be designed or occupied by more than 24 families.
(7) No building shall exceed 160 feet in length at its longest dimension.
(8) No wall of a principal building fronting on a street shall exceed 100 feet in length.
(9) All multifamily buildings shall provide not less than two exterior exposures for each family unit, the same properly pierced by windows or other openings so as to provide through ventilation or cross ventilation for the unit.
(10) Distance between buildings.
(a) The minimum distance between principal buildings shall be the average height of such buildings at the point where the buildings are nearest to each other, except that the minimum distance between the ends of buildings shall be 20 feet.
(b) The minimum width of a court shall be 45 feet, and the depth of a court shall not exceed its width.
(c) The minimum distance between a principal building and a one-story accessory building shall be 20 feet.
(d) The minimum distance between two accessory buildings shall be 10 feet.
(e) At the inner angles of a court, the distance between windows of bedrooms, living rooms and kitchens shall be not less than 12 feet, measured diagonally across the court.
(11) All areas not covered by buildings, parking areas or walkways shall be suitably landscaped and improved for maximum outdoor living use, including gardens and recreation areas, where appropriate.
C. For townhouses, the following requirements shall apply:
(1) Maximum building height and number of stories.
(a) The maximum building height shall be 35 feet. No dwellings or parts of dwellings, except for storage and utilities areas, shall be located more than two feet below the adjoining general grade level, with light wells not counted as part of the adjoining grade level.
(b) Maximum number of stories: 2 1/2.
(2) The minimum front yard setback shall be the average setback of the existing buildings on two adjacent properties on both sides of the subject property, with a minimum setback of no less than 30 feet. A corner lot and a through lot shall provide such required minimum front yard for each street frontage.
(3) The minimum side yard setback shall be 18 feet, except that where buildings extend for a length of more than 80 feet along the side line, a section or sections over 80 feet in length shall have a minimum setback of 30 feet, and if there is more than one building section with a length of up to 80 feet with a minimum setback, these sections shall be separated by a distance of at least 50 feet.
(4) The minimum rear yard setback shall be 40 feet.
(5) The principal building or buildings shall not occupy more than 20% of the ground area of the site.
(6) No building shall exceed 100 feet in length at its longest dimension.
(7) The minimum width of each townhouse unit shall be 20 feet.
(8) All townhouses shall provide not less than two exterior exposures for each family unit, the same properly pierced by windows or other openings so as to provide through ventilation or cross-ventilation for the unit.
(9) The maximum number of adjoining townhouse units in a row shall be five.
(10) Distance between buildings.
(a) The minimum distance between principal buildings shall be 25 feet.
(b) The minimum width of a court shall be 45 feet, and the depth of a court shall not exceed its width.
(c) The minimum distance between a principal building and a one-story accessory building shall be 20 feet.
(d) The minimum distance between two accessory buildings shall be 10 feet.
(e) At the inner angles of a court, the distance between windows of bedrooms, living rooms and kitchens shall be not less than 12 feet, measured diagonally across the court.
(11) The maximum impervious surface coverage for townhouse projects shall be 50%.
(12) All areas not covered by buildings, parking areas or walkways shall be suitably landscaped and improved for maximum outdoor living use, including gardens and recreation areas, where appropriate.