Safe Sight Distance
| |||
---|---|---|---|
Operating Speed
(miles per hour)
|
Left
(feet)
|
Right
(feet)
| |
20
|
130
|
130
| |
30
|
220
|
260
| |
40
|
380
|
440
| |
50
|
620
|
700
|
Minimum Standards for Corner Clearance
| |||
---|---|---|---|
Minimum Corner Clearance (Dc)
| |||
Access Type
|
Intersection Signalized
(feet)
|
Intersection Unsignalized
(feet)
| |
Low-volume residential
|
150
|
50
| |
High-volume residential
|
150
|
50
| |
Commercial
|
500
|
250
|
Minimum Access Spacing
| |||||
---|---|---|---|---|---|
Minimum Spacing to Adjacent Access
by Access Type2 (Dsp)3
| |||||
Access Type
|
Minimum Spacing to Property Line (Dpl)1
(feet)
|
Low
Resident
(feet)
|
High
Resident
(feet)
|
Comm
w/o RT
(feet)
|
Comm
w/ RT
(feet)
|
Low-volume residential
|
5
|
50
|
50
|
75
|
100
|
High-volume residential
|
10
|
50
|
75
|
100
|
150
|
Commercial
(w/o RT)4
|
10
|
75
|
100
|
150
|
250
|
Commercial (w/RT)5
|
10
|
100
|
150
|
250
|
400
|
NOTES:
| ||||||
1
|
Dpl measured from point of tangency of access
to projection of property line on roadway edge.
| |||||
2
|
For two more accesses serving a single parcel,
or from a proposed access from an existing access.
| |||||
3
|
Dsp measured from point of tangency of access
to point of tangency of adjacent access.
| |||||
4
|
Access without right turn channelization.
| |||||
5
|
Access with right turn channelization.
|
Design Speed
(miles per hour)
| |||||
---|---|---|---|---|---|
20
|
25
|
30
|
35
| ||
Stopping sight distance (feet)
|
125
|
150
|
200
|
250
|
Minimum Pavement Materials Thicknesses
| ||||||
---|---|---|---|---|---|---|
Street Materials
|
Commercial
|
Collector
|
Local
|
Private Way
| ||
Aggregate subbase course (maximum sized stone
6 inches) (inches)
|
20
|
15
|
15
|
12
| ||
Crushed aggregate base course (inches)
|
4
|
3
|
3
|
3
| ||
Hot bituminous pavement (inches)
| ||||||
Total thickness
|
4 1/2
|
3
|
3
|
N/A
| ||
Surface course [MeDOT 403.210 Superpave Mix
3/8 inch (9.5mm)]
|
1 1/2
|
1
|
1
|
N/A
| ||
Base course [MeDOT 403.207 Superpave Mix 3/4
inch (19mm)]
|
3
|
2
|
2
|
N/A
| ||
Surface gravel (inches)
|
N/A
|
N/A
|
N/A
|
2
|
Aggregate Subbase Grading Requirements
| ||
---|---|---|
Sieve Designation
|
Percentage by Weight Passing Square Mesh
Sieves
| |
1/4 inch
|
25% to 70%
| |
No. 40
|
0% to 30%
| |
No. 200
|
0% to 7%
|
Base Course Grading Requirements
| ||
---|---|---|
Sieve Designation
|
Percentage by Weight Passing Square Mesh
Sieves
| |
3/8 inch
|
45% to 70%
| |
1/4 inch
|
30% to 55%
| |
No. 50
|
0% to 20%
| |
No. 200
|
0% to 5%
|
Surface Gravel Grading Requirements
| ||
---|---|---|
Sieve Designation
|
Percentage by Weight Passing Square Mesh
Sieves
| |
2 inch
|
95% to 100%
| |
2 inch
|
30% to 65%
| |
No. 200
|
7% to 12%
|
Culvert Size and Thicknesses Material
| |||
---|---|---|---|
Inside Diameter
(inches)
|
Galvanized CMP
Aluminum/Zinc Coated CMP
Corrugated Aluminum Alloy
|
Aluminum Coated CMP
Polymer Coated CMP
| |
15 to 24
|
14 ga.
|
16 ga.
| |
30 to 36
|
12 ga.
|
14 ga.
| |
42 to 54
|
10 ga.
|
12 ga.
| |
60 to 72
|
8 ga.
|
10 ga.
|
Buffer Strip Widths
| |||
---|---|---|---|
Buffer Width Per Lot
(feet)
| |||
Lot Size
(acres)
|
HSG
|
Clearing Restricted
to 12,500 Square Feet
|
No Clearing
Restrictions
|
Less than 1
|
A
|
50
|
75
|
B
|
75
|
100
| |
C
|
N/A
|
N/A
| |
D
|
N/A
|
N/A
| |
1 to 1.99
|
A
|
25
|
25
|
B
|
25
|
55
| |
C
|
55
|
190
| |
D
|
200
|
N/A
| |
2 to 2.99
|
A
|
25
|
25
|
B
|
25
|
25
| |
C
|
25
|
50
| |
D
|
25
|
200
|
Notes:
| |||
HSG is the hydrologic soil group.
| |||
All lots three acres and larger shall provide
a minimum twenty-five-foot buffer.
|