Establishments shall comply with §§ 87-71 through 87-74.
A. 
Hot and cold running water under pressure need not be piped to temporary eating and drinking places whenever:
(1) 
The only utensils are limited to knives, spatulas, tongs and similar devices or a single container.
(2) 
Extensive soiling of the establishment from the food operation does not occur.
(3) 
The equipment to be cleaned is stationary and does not require disassembly for proper cleaning.
(4) 
No health hazard will result.
B. 
When the conditions of Subsection A are met, the proprietor shall comply with the following:
(1) 
Water required for cooking, cleaning and handwashing shall be obtained in a container which has a tight-fitting lid and is easily cleaned.
(2) 
The outlet from which the water is obtained shall be so located and protected as to preclude contamination of the water outlet as well as the water being drawn.
(3) 
An adequate quantity of water shall be provided within the establishment in containers approved by the Public Health Office for design, construction and size.
Mobile food-service establishments shall comply with the following requirements:
A. 
The water system shall be closed to contamination from the filling inlet to the discharge outlets. Vent openings are permitted wherever necessary, if properly protected to prevent contamination of the water supply.
B. 
The water-filling inlet shall be so located and designed that it is protected from contamination, provided with a hose connection of a different size and type from the waste retention tank flushing connections on the mobile unit, and easily accessible.
C. 
The water storage tank shall have a minimum capacity equivalent to the amount needed for one day of operation, but in no case may be less than 5 gallons, unless otherwise approved by the Public Health Officer.
D. 
Whenever the waste retention tank is cleaned or flushed in place, two separate hoses shall be provided for the servicing operation, one for use in filling the water storage tank and one for the use in flushing the waste retention tank.
E. 
The water fill hose, unless otherwise protected from contamination, shall have the end of the hose provided with a permanently attached disc or molded protection so that the nozzle will not rest on the ground or floor if dropped. The filler hose shall be kept in the vehicle and shall be protected from contamination.
F. 
Hot water generating facilities shall be provided which are able to function whether the vehicle is mobile or stationary.
A. 
Mobile food-service establishments shall comply with the following requirements:
(1) 
A suitable liquid waste system including a waste tank having a capacity of five gallons greater than the water storage and distribution system and hot water generating system combined, shall be provided. The waste tank shall be capable of being completely drained and flushed.
(2) 
When wastes are retained in removable soil or waste cans, provision shall be made to fix the cans in place so as to prevent excrement or waste from falling or spilling outside of the container.
(3) 
When the soil can is removed from the mobile unit, the contents shall be enclosed or covered while being transported to the facilities for emptying and cleaning the cans.
(4) 
Hoses used to clean soil cans shall be equipped with acceptable vacuum breakers installed on the discharge side of the last control valve.
(5) 
When wastes are stored in retention tanks which are permanently installed on the mobile unit, the tanks shall be so designed that the contents cannot be discharged when the vehicle is in motion. In addition, discharge control devices on the retention tank outlet shall be designed to prevent leakage and to prevent spattering of the servicing area or servicing area personnel.
(6) 
The disposal of all waste shall be done so as to not to create a nuisance or health hazard.
B. 
Temporary food-service establishments which do not have water piped to their facility and which do not have a plumbing system within their facility that connects to an approved waste disposal system shall:
(1) 
Provide a waste water container which has a minimum capacity of five gallons, a tight-fitting lid and design and construction features that permit ease of cleaning.
(2) 
Clean and empty the container each day.
(3) 
Dispose of all waste water so as not to cause a health hazard or nuisance.
Temporary food-service establishments and mobile food-service establishments shall have available adequate, conveniently located toilet facilities for its employees. A mobile food-service establishment shall be provided with toilet facilities approved by the Public Health Officer on the vehicle if the operator does not have access to facilities at his designated stops or base of operation.
A. 
Temporary or mobile food-service establishments shall be provided with adequate, conveniently located hand-washing facilities for its employees, including lavatory or lavatories equipped with hot and cold tempered running water under pressure, hand cleansing soap or detergent and approved sanitary towels or other approved hand-drying devices.
B. 
Temporary food-service establishments which do not have water piped to their facilities may utilize the following:
(1) 
Auxiliary heating facilities to produce an ample supply of hot water.
(2) 
A basin or pan in lieu of a sink. The container shall be emptied and rinsed immediately after each person's use.
(3) 
An adequate quantity of water shall be provided within the establishment in containers approved by the licensor for design, construction and size.
Temporary establishments shall comply with §§ 87-77 and 87-78 (relating to garbage and refuse disposal; and insect and rodent control).