The district established by this article is
in accordance with the land use policies and objectives established
by the Montgomery Township Comprehensive Plan. It is intended to achieve
the following:
A. To encourage construction of mixed housing types to
meet the housing needs of a changing population in Montgomery Township.
B. To preserve and support the character of existing
residential uses in the Township.
C. To assure light, air and privacy, as far as possible,
by controlling the spacing and height of buildings and other structures.
D. To protect residential areas against hazards of fire,
offensive noise, vibration, smoke, odors, glare or other objectionable
influences.
E. To prevent congestion, as far as possible, by regulating
the density of population and the bulk of buildings and by providing
for sufficient off-street parking.
F. To protect residential neighborhoods, as much as possible,
from heavy or through traffic.
In the R-3 Residential Districts, the following
area, height and bulk regulations shall apply as to townhouse and
garden apartment development:
Site Area
|
Townhouse
|
Apartment
|
---|
Size (minimum acres)
|
10
|
10
|
Buffer
|
|
|
|
Front (minimum feet from property line)
|
75
|
75
|
|
Side (minimum feet from property line)
|
50
|
50
|
|
Rear (minimum feet from property line)
|
50
|
50
|
Common open space (minimum percentage of total
open space)
|
50
|
50
|
Building coverage (maximum percentage of net
site area)
|
35
|
35
|
Impervious material coverage, excluding building
coverage (maximum percentage of net site area)
|
30
|
30
|
Dwelling (building) lot area
|
|
N/A
|
Lot size (minimum square feet per dwelling
unit)
|
|
|
|
Building coverage (maximum percentage of lot
area)
|
50
|
50
|
|
Impervious material coverage (maximum percentage
of net site area)
|
30
|
30
|
|
Outdoor living space (minimum square feet per
dwelling unit)
|
(See entry below)
|
750
|
Dwelling unit lot area
|
|
|
|
Lot size (minimum square feet)
|
|
N/A
|
|
Outdoor living space adjacent to exterior:
|
|
|
|
Front walls of unit (minimum feet
from wall)
|
15
|
N/A
|
|
Side walls of unit (minimum feet
from wall)
|
10
|
N/A
|
|
Back walls of unit (minimum feet
from wall)
|
10
|
N/A
|
Dwelling (building)
|
|
|
Height (maximum feet)
|
35
|
35
|
Setback from:
|
|
|
|
Main distribution roads (minimum feet)
|
40
|
40
|
|
Building service roads (minimum feet)
|
30
|
30
|
|
Common parking area (minimum feet)
|
15
|
15
|
|
Other buildings (minimum feet)
|
|
|
|
Option A
|
40
|
40
|
|
Option B (townhouse, dwelling only)
|
|
|
|
Front to front
|
60
|
N/A
|
|
Front to back
|
60
|
N/A
|
|
Back to back
|
60
|
N/A
|
|
Side to front/back
|
40
|
N/A
|
|
Side to side
|
25
|
N/A
|
Dwelling unit
|
|
|
Number of units per gross acre (maximum number)
|
9
|
10
|
Number of units per building (maximum number)
|
|
|
|
Under Option A
|
12
|
16
|
|
Under Option B (townhouse only)
|
8
|
N/A
|
Setback from other units, same building, wholly
facing or end-to-end (minimum feet)
|
40
|
40
|
Parking spaces per dwelling unit (minimum)
|
2
|
2
|
In an R-3 Residential District, the following
requirements shall apply:
A. The development shall be constructed in accordance
with an overall plan and shall be designed as a unified architectural
unit with approved landscaping.
B. Provision shall be made for ownership and maintenance
responsibility of all property contained in the development, and the
development plan shall indicate areas to be held in single ownership
and in common ownership.
C. All paved areas for vehicular use, all pedestrian
walks and other paved areas shall be constructed in accordance with
the requirements of the applicable Township regulations, including
those of the Subdivision Ordinance.
D. Fire lanes, as required by the Fire Marshal, and areas
for loading and unloading of delivery trucks and other vehicles and
for the servicing of refuse collection, fuel and other services shall
be provided and shall be adequate in size and shall be so arranged
that they may be used without blockage or interference with the use
of accessways or automobile parking facilities.
E. Provision shall be made for safe and efficient ingress
and egress to and from public streets and highways serving the development
site without undue congestion to or interference with normal traffic
flow.
F. All utility lines servicing the development shall
be placed underground.
G. All buildings shall be served by a municipal public
sanitary sewage disposal system and municipal public water supply,
including fire hydrants.
H. Lighting facilities provided shall be arranged in
a manner which will protect the highway and neighboring properties
from unreasonable direct glare or hazardous interference of any kind.
Lighting facilities shall be required where deemed necessary by the
Board of Supervisors for the safety and convenience of the residents.
I. Landscaping and screening. All landscaping, screening and buffering shall be installed in accordance with the provisions of the Montgomery Township Subdivision Ordinance, No. 18, Chapter
205, Article
VI.
[Amended 8-3-1987 by Ord. No. 17-033]
J. The developer shall preserve or incorporate natural
features such as woods, streams, floodplains and open space areas
which add to the overall cohesive development of the Apartment Residential
District and adjacent districts.
K. The developer shall give consideration to the provision
of community areas, laundry facilities, playgrounds, open space and
other services necessary for the comfort and convenience of the residents.
L. Trash receptacles. All buildings shall be provided
with trash receptacles convenient to service entrances and screened
or enclosed as a part of the architectural treatment of the building.
Incinerators are not permitted in the buildings.
M. All mechanical equipment shall be installed and maintained
so that no noise therefrom can be heard at the property line.
N. Elevators. Where elevators are provided, the developer
shall submit detailed information of the size and rate of elevators
and their adequacy to serve the proposed building. In order to provide
adequate room in elevators for ambulance stretchers and emergency
equipment, at least one elevator must have one horizontal dimension
which is at least eight feet (inside cab).
O. Snow removal. Snow shall be removed from all roadways,
sidewalks and parking areas within four hours after snow has ceased
to fall. The application for a building permit shall indicate the
method of removing snow, including storage areas for such snow located
so that they will not interfere with vehicular or pedestrian movement
or visibility.
P. Security. Sliding patio doors shall be equipped with
jam-proof dead locks and exterior and interior five-pin cylinder locks.
All hinged entrance doors to apartments shall be equipped with heavy-duty
locksets having a minimum throw of 3/4 inch on latches and an
auxiliary latch/deadlocking latch bolt when door is closed.
Q. All buildings shall be designed to meet all requirements
of Building Regulations for Protection from Fire and Panic, Commonwealth
of Pennsylvania, Department of Labor and Industry. No building permits
are to be issued until evidence of submittal and approval by the above
agency is furnished to the Township. No buildings or dwelling units
are to be occupied until copies of the Department of Labor and Industry
occupancy permit are furnished to the Township, showing evidence that
buildings have been inspected and comply with the approved drawings
and all other requirements of the Department of Labor and Industry.
R. All surface water drainage shall be collected and
conveyed in accordance with proper engineering practices and design,
as approved by the Township Engineer.
S. Attached buildings shall have breaks in both the roofline
and the front and rear building walls as specified below. Breaks shall
be utilized so as to minimize earthmoving and removal or impacting,
due to cut or fill, on adjacent existing vegetation.
(1) Vertical breaks. A total break footgage of four vertical
feet in minimum increments of 18 inches shall be included in every
160 horizontal building feet or within three firewalls.
(2) Horizontal breaks. A total break footgage of eight
horizontal feet in minimum increments of three feet shall be included
in every 160 horizontal building feet or within three firewalls. In
addition, angles in the building wall of 22º or more shall be
considered equivalent to a five-foot break. Breaks in walls shall
be varied by change in building texture, provided that a common architectural
theme is carried out by means of consistent exterior detailing, materials
and colors.
[Added 7-28-1986 by Ord. No. 17-037]
See Article
XXI of this Zoning Ordinance for general provisions that may also relate to this District.