Return Period
|
Twenty-Four-Hour Rainfall Depth
(inches)
| |
---|---|---|
2-year
|
2.90
| |
10-year
|
4.37
| |
25-year
|
5.44
| |
50-year
|
6.40
| |
100-year
|
7.50
|
Type of Pipe
|
Manning's "n" Value
| ||
---|---|---|---|
Concrete
|
0.012
| ||
Smooth lined plastic
|
0.011
| ||
Corrugated plastic
|
0.024
| ||
Smooth lined corrugated metal
|
0.012
| ||
Annular corrugated metal
|
0.027
| ||
Helical corrugated metal
| |||
21" and under
|
0.019
| ||
24" to 30"
|
0.020
| ||
36" to 60"
|
0.021
| ||
Over 60"
|
0.023
| ||
Annular or helical noncircular corrugated metal
|
0.024
| ||
Vitrified clay
|
0.012
| ||
Ductile iron
|
0.013
|
Drainage Area
(acres)
|
Method
| |
---|---|---|
Less than 10
|
Modified Rational Method
| |
10 to 20
|
Modified Rational Method or NRCS soil cover complex method
| |
Greater than 20
|
NRCS soil cover complex method
|
Rev = (S x Rv x
A)/12
|
Where:
| ||||
Rev
|
=
|
Recharge volume (acre-feet)
| ||
S
|
=
|
Soil-specific recharge factor (inches)
| ||
Rv
|
=
|
Volumetric runoff coefficient
| ||
A
|
=
|
Site area contributing to the recharge facility (acres)
| ||
And:
|
Rv = 0.05 + (0.009 x 1)
|
Where:
| ||||
I
|
=
|
Percent impervious area, (impervious coverage area/A) x 100
| ||
And:
| ||||
S may be obtained based upon HSG as shown in the table below,
recommended as general values by PADEP. More site-specific data may
be utilized to determine recharge if justified by the design professional
and approved by the Township Engineer.
|
Hydrologic Soil Group
(HSG)
|
Soil-Specific Recharge Factor (S)
(inches)
| |
---|---|---|
A
|
0.38
| |
B
|
0.25
| |
C
|
0.13
| |
D
|
0.06
| |
If more than 1 HSG is present at a site, a composite recharge
volume shall be computed based upon the proportion of total site area
within each HSG.
|
"I hereby certify that, to the best of my knowledge, the proposed
detention basin(s) is(are)/is(are) not underlain by limestone."
|
WQv = (P x Rv x
A)/12
|
Where:
| ||||
WQv
|
=
|
Water quality volume (acre-feet)
| ||
P
|
=
|
1.95 inches (twenty-four-hour storm volume representing 90%
of annual rainfall for PennDOT Region 4)
| ||
Rv
|
=
|
Volumetric runoff coefficient
| ||
A
|
=
|
Site area contributing to the water quality volume storage facility
(acres)
|
And:
| |
---|---|
Rv = 0.05 + (0.009 x I)
|
Where:
| ||||
---|---|---|---|---|
I
|
=
|
Percent impervious area, (impervious coverage area/A) x 100
|