Electrical installations. Electrical installations in connection
with earth satellite receiving stations, including grounding of the
system, shall be in accordance with the National Electrical Safety
Code, Wisconsin State Electrical Code and the instructions of the
manufacturer. In cases of conflict, the stricter requirements shall
govern. All cable used to conduct current or signals from the satellite
earth station to the receivers shall be installed underground unless
installation site conditions preclude underground. If a satellite
earth station is to be used by two or more residential property owners,
all interconnecting electrical connections, cables and conduits must
also be buried. The location of all such underground lines, cables
and conduits shall be shown on the application for a permit. All satellite
earth stations shall be grounded against direct lightning strikes.