A. International
Building Code. A certain code, two (2) copies of which are on file
in the office of the City Clerk of the City of De Soto, Missouri,
being marked and designated as "The International Building Code, 2009
Edition" as published by the International Code Council is hereby
adopted as the Building Code of the City of De Soto, Missouri regulating
and governing the conditions and maintenance of all property, buildings
and structures; by providing the standards for supplied utilities
and facilities and other physical things and conditions essential
to ensure that structures are safe, sanitary and fit for occupation
and use; and the condemnation of buildings and structures unfit for
human occupancy and use and the demolition of such structures as herein
provided; providing for the issuance of permits and collection of
fees therefore; and each and all of the regulations, provisions, penalties,
conditions and terms of said Building Code on file in the office of
the City of De Soto are hereby referred to, adopted and made a part
hereof, as if fully set out in this Article.
B. Existing
Building Code. A certain code, one (1) copy of which is on file in
the office of the City Clerk of the City of De Soto, Missouri, being
marked and designated as "The International Existing Building Code,
2009 Edition," as published by the International Code Council, is
hereby adopted as the Existing Building Code of the City of De Soto,
Missouri, regulating and governing the repair, alteration, change
of occupancy, addition, and relocation of existing buildings, including
historic buildings, as herein provided; and each and all of the regulations,
provisions, conditions and terms of said Existing Building Code on
file in the office of the City of De Soto are hereby referred to,
adopted and made a part hereof, as if fully set out in this Article.
C. Residential
Code. A certain code, two (2) copies of which are on file in the office
of the City Clerk of the City of De Soto, Missouri, being marked and
designated as "The International Residential Code, 2009 Edition,"
including entire Appendix as published by the International Code Council,
is hereby adopted as the Residential Code of the City of De Soto,
Missouri, regulating and governing the construction, alteration, movement,
enlargement, replacement, repair, equipment, location, removal and
demolition of detached one- and two-family dwellings and multiple
single-family dwellings (town houses) not more than three (3) stories
in height with separate means of egress as herein provided; and each
and all of the regulations, provisions, conditions and terms of said
Residential Code on file in the office of the City of De Soto are
hereby referred to, adopted and made a part hereto, as if fully set
out in this Article.
D. Mechanical
Code. A certain code, one (1) copy of which is on file in the office
of the City Clerk of the City of De Soto, Missouri, being marked and
designated as "The International Mechanical Code, 2009 Edition," as
published by the International Code Council, is hereby adopted as
the Mechanical Code of the City of De Soto, Missouri, regulating and
governing the design, construction, quality of materials, erection,
installation, alteration, repair, location, relocation, replacement,
addition to, use or maintenance of mechanical systems as herein provided;
and each and all of the regulations, provisions, conditions and terms
of said Mechanical Code on file in the office of the City of De Soto
are hereby referred to, adopted and made a part hereto, as if fully
set out in this Article.
E. Plumbing
Code. A certain code, one (1) copy of which is on file in the office
of the City Clerk of the City of De Soto, Missouri, being marked and
designated as "The International Plumbing Code, 2009 Edition," as
published by the International Code Council, is hereby adopted as
the Plumbing Code of the City of De Soto, Missouri, regulating and
governing the design, construction, quality of materials, erection,
installation, alteration, repair, location, relocation, replacement,
addition to, use or maintenance of plumbing systems as herein provided;
and each and all of the regulations, provisions, conditions and terms
of said Plumbing Code on file in the office of the City of De Soto
are hereby referred to, adopted and made a part hereto, as if fully
set out in this Article.
F. Energy
Conservation Code. A certain code, one (1) copy of which is on file
in the office of the City Clerk of the City of De Soto, Missouri,
being marked and designated as "The International Energy Conservation
Code, 2003 Edition," as published by the International Code Council,
is hereby adopted as the International Energy Conservation Code of
the City of De Soto, Missouri, regulating and governing efficient
building envelopes and installation of energy efficient mechanical,
lighting and power systems as herein provided; and each and all of
the regulations, provisions, conditions and terms of said Energy Conservation
Code on file in the office of the City of De Soto are hereby referred
to, adopted and made a part hereto, as if fully set out in this Article.
G. Fuel
Gas Code. A certain code, one (1) copy of which is on file in the
office of the City Clerk of the City of De Soto, Missouri, being marked
and designated as "The International Fuel Gas Code, 2003 Edition,"
as published by the International Code Council, is hereby adopted
as the Fuel Gas Code of the City of De Soto, Missouri, regulating
and governing fuel gas systems and gas-fired appliances as herein
provided; and each and all of the regulations, provisions, conditions
and terms of said Fuel Gas Code on file in the office of the City
of De Soto are hereby referred to, adopted and made a part hereto,
as if fully set out in this Article.
H. Urban-Wildland
Interface Code. A certain code, one (1) copy of which is on file in
the office of the City Clerk of the City of De Soto, Missouri, being
marked and designated as "The International Urban-Wildland Code, 2003
Edition," as published by the International Code Council, is hereby
adopted as the Urban-Wildland Interface Code of the City of De Soto,
Missouri, regulating and governing the mitigation of hazard to life
and property from the intrusion of fire from wildland exposures, fire
from adjacent structures and prevention of structure fires from spreading
to wildland fuels as herein provided; and each and all of the regulations,
provisions, conditions and terms of said Urban-Wildland Interface
Code on file in the office of the City of De Soto are hereby referred
to, adopted and made a part hereto, as if fully set out in this Article.
I. Electrical
Code. A certain code, three (3) copies of which are on file in the
office of the City Clerk of the City of De Soto, Missouri, being marked
and designated as the "National Electrical Code, 2005 Edition," as
published by the National Fire Protection Association, is hereby adopted
as the Electrical Code of the City of De Soto, Missouri, to provide
for the regulation and control of design, construction, quality of
materials, erection, installation, alteration, repair, location, relocation,
replacement, addition to, use or maintenance of electrical systems
in the City of De Soto; and each and all of the regulations, provisions,
conditions and terms of said National Electrical Code, and the referenced
standards mentioned therein are hereby referred to, adopted and made
a part hereof, as if fully set out in this Article.
J. Property
Maintenance Code. A certain code, three (3) copies of which are on
file in the office of the City Clerk of the City of De Soto, Missouri,
being marked and designated as the "International Property Maintenance
Code, 2009 Edition," as published by the International Code Council,
is hereby adopted as the Property Maintenance Code of the City of
De Soto, Missouri, regulating and governing the maintenance of existing
buildings; and each and all of the regulations, provisions, penalties,
conditions and terms of said International Property Maintenance Code
on file in the office of the City of De Soto are hereby referred to,
adopted and made a part hereof, as if fully set out in this Article.
[Ord. No. 3718 §1, 1-22-2007; Ord. No. 3719 §1, 2-21-2007; Ord. No. 3768 §1, 5-19-2008; Ord. No. 3887 §1, 5-16-2011; Ord. No. 4139, 11-19-2018]
A. The
International Building Code is amended and changed in the following
respects:
CHAPTER 1 OF (THE INTERNATIONAL BUILDING CODE)
The following Sections of the International Building Code, 2009
Edition, are revised as follows:
1. Amend Section 101.1 Title: Insert "City of De Soto, Missouri."
2. Amend Section 101.2.1 Appendices to read: "Appendix H Signs is hereby
adopted."
3. Amend Subsection 101.4.3 Plumbing by replacing "International Private
Sewage Disposal Code" with "Jefferson County On-Site Sewage Treatment
Code" where it appears in the International Building Code 2009.
4. Amend Section 103.2 to read: "The Building Official, under the code,
shall be the City Manager or the duly authorized representative of
the City Manager."
5. Amend Section 105.1 by adding to the end of the paragraph: "A copy
of the real estate tax bill, from the prior year, must be accompanied
with the building permit application."
6. Amend Section 107.2.5 by adding to the end of the paragraph: "The
owner must have the corners of the property marked as well as the
proposed building staked as to position on the lot. The position of
the building on the property will be shown on a site plan submitted
prior to issue of a building permit."
7. Amend Section 109.2. Fee Schedule by adding schedule:
a. Residential And Commercial New Construction. The permit fee shall
be thirty cents ($0.30) per square foot from April 1, 2011 through
March 31, 2012. Thereafter, the fee will increase 3% annually on April
1st.
b. Remodeling Permit. Shall be the fee "times" the square footage divided
by two (2) or the number of times an inspection is needed, whichever
is less.
c. All other permits, or in the case where an area cannot be determined
or is impractical to be determined. The non-refundable permit fee
shall be thirty dollars ($30.00).
d. Payment. All permit fees shall be paid prior to construction.
e. Re-Inspections. Permit fees will cover up to ten (10) inspections.
After ten (10) inspections a fee of thirty dollars ($30.00) will be
charged for each inspection. This Section does not apply to commercial
inspections.
f. Property Maintenance/Occupancy Inspections. The permit fee for Property
Maintenance/Occupancy Inspections shall be thirty dollars ($30.00).
This permit fee will cover up to one (1) inspection and two (2) re-inspections.
All additional Property Maintenance/Occupancy re-inspections require
the payment of an additional fee of thirty dollars ($30.00) to be
paid prior to the time of re-inspection.
8. Amend Section 110.3.5 by replacing "Shall be made" with "may be made."
9.
Amend Section 113.
Board of Appeals by deleting Sections 113.1, 113.2, 113.3 and inserting
in lieu thereof the following:
SECTION 113. MEANS OF APPEAL.
SECTION 113. APPLICATION FOR APPEAL. (INTERNATIONAL BUILDING
CODE, INTERNATIONAL EXISTING BUILDING CODE, INTERNATIONAL RESIDENTIAL
CODE, INTERNATIONAL MECHANICAL CODE, INTERNATIONAL PLUMBING CODE,
INTERNATIONAL ENERGY CONSERVATION CODE, INTERNATIONAL FUEL GAS CODE,
INTERNATIONAL URBAN-WILDLAND INTERFACE CODE, NATIONAL ELECTRICAL CODE
AND INTERNATIONAL PROPERTY MAINTENANCE CODE).
A. Application. Any person aggrieved by a decision of the Code Official shall have the right to appeal that decision to the Board of Adjustment established in Section
405.410, De Soto Code. An application for appeal shall be based on a claim that the true intent of the International Building Code, International Existing Building Code, International Residential Code, International Mechanical Code, International Plumbing Code, International Energy Conservation Code, International Fuel Gas Code, International Urban-Wildland Interface Code, the National Electrical Code or the International Property Maintenance Code, or the rules legally adopted thereunder, have been incorrectly interpreted, the provisions of this code do not fully apply, or that the Code Official agrees that an equally good or better method of construction is used. The application shall be filed on a form obtained from the Code Official within (30) days after the notice was served or the decision made by filing the application with the Code Official and with the Board of Adjustment. The Code Official shall forthwith transmit to the Board of Adjustment all the papers constituting the record upon which the action appealed from is taken. The Board shall fix a reasonable time for hearing the appeal, provide reasonable notice to the parties and decide the same within a reasonable time. Meetings of the Board of Adjustment shall be held in compliance with Section
405.410, De Soto Code.
B. Meetings — Procedure. Meetings of the Board of Adjustment shall be held in compliance with Section
405.410, De Soto Code.
C. Resolution. The decision of the board shall be by resolution. Certified
copies shall be furnished to the applicant and to the Code Official.
D. Board Decision.
1. The Board of Adjustment may modify or reverse the decision of the
Code Official by the concurring vote of four (4) members of the Board
of Adjustment. Otherwise, the decision will be affirmed.
2. The Code Official shall take immediate action in accordance with
the decision of the Board of Adjustment.
E. Court Review. Appeals to the Circuit Court by any person aggrieved
by a decision of the Board of Adjustment shall be made in the manner
and time required by law following the issuance of the decision by
the Board of Adjustment.
F. Penalty For Violations (International Building Code, International
Existing Building Code, International Residential Code, International
Mechanical Code, International Plumbing Code, International Energy
Conservation Code, International Fuel Gas Code, International Urban-Wildland
Interface Code, National Electrical Code and International Property
Maintenance Code). Any person, firm or corporation who shall violate
any of the provisions of this Chapter or the codes herein adopted,
or who shall fail to comply with any of the requirements thereof,
or who shall fail to comply with any order issued pursuant to any
Section thereof shall be guilty of a misdemeanor, and upon conviction,
shall be punished by a fine not exceeding five hundred dollars ($500.00),
or by imprisonment for a period not to exceed three (3) months, or
by both such fine and imprisonment, and court costs for each such
offense. Each day a violation exists or continues to exist shall be
deemed a separate offense.
10. Amend Subsection 406.1.4 Separation #1 by replacing "½ inch"
with "5/8 inch," and by replacing "1 3/8 inch" with "1 ¾ inch."
11. Amend Section 1807.2.1 Retaining Walls to read: "Retaining walls
over six (6) feet shall be designed by an engineer to ensure stability
against overturning, sliding, excess foundation pressure and water
uplift. Retaining walls shall be designed for a safety factor of 1.5
against lateral sliding and overturning."
"Exception: Poured concrete and wood crafted retaining walls
not exceeding six (6) feet in height shall not require engineering
but shall meet all other design requirements. Pre-manufactured block
retaining system of a modular nature shall follow manufacturer's specifications.
Modular retaining wall systems over six (6) feet in height shall require
engineered design supervision. Retaining walls of wood construction
shall be preservative treated in accordance with Chapter 23 of the
International Building Code."
[Ord. No. 3718 §1, 1-22-2007; Ord. No. 3887 §1, 5-16-2011]
The International Existing Building Code is amended and changed
in the following respects:
CHAPTER 1 OF (THE INTERNATIONAL EXISTING BUILDING CODE)
The following Sections of the International Existing Building
Code, 2009 Edition, are revised as follows:
1. Amend
Section 101.1: Insert "City of De Soto, Missouri".
2. Amend
Section 103.2 by replacing the entire Section with: "The Building
Official, under the code, shall be the City Manager or the duly authorized
representative of the City Manager."
3. Amend
Section 105.1 by adding to the end of the paragraph: "A copy of the
real estate tax bill for the prior year must be accompanied with the
building permit application."
4. Amend
Section 106.2 by adding to the end of the paragraph: "The owner must
have the corners of the property marked as well as the proposed building
staked as to position on the lot. The position of the building on
the property will be shown on a site plan submitted prior to issue
of a building permit."
5. Amend Section 108.2. Schedule of Permit Fees to read: See "Fee Schedule" as provided in Section
500.020.
6. Amend Section 112. Means of Appeal to read: See "Means of Appeal" as provided in Section
500.020.
[Ord. No. 3718 §1, 1-22-2007; Ord. No. 3887 §1, 5-16-2011]
The International Residential Code is further amended and changed
in the following respects:
CHAPTER 1 (OF INTERNATIONAL RESIDENTIAL CODE)
The following Sections of the International Residential Code,
2009 Edition, are revised as follows:
1. Amend
Section R101.1: Insert "City of De Soto, Missouri".
2. Amend
Section R103.2 by replacing the entire Section with: "The Building
Official, under the code, shall be the City Manager or the duly authorized
representative of the City Manager."
3. Amend Section R104.10.1 to read: Refer to City Code Article IV Section
420.120.
4. Amend
R105.2 by deleting: Work exempt from permit #1, #2, #4, #5, #7, #10
— Decks not exceeding 200 square feet in area and no more than
30 inches above grade at any point....
5. Amend
Section R110.3 by deleting #8 - If an automatic sprinkler system is
provided and whether the sprinkler system is required (means we are
not requiring sprinkler in residential houses).
6. Amend Section R112 to read: See "Means of Appeal" as provided in Section
500.020 of this ordinance.
7. Amend Section R113 to read: See "Penalty for Violations" as provided in Section
500.020 of this ordinance.
8. Amend
Subsection R301.2 (1) Table by inserting the following information:
|
Roof Snow Load:
|
20
|
|
Wind Speed (mph):
|
90
|
|
Seismic Design Category:
|
D-0
|
|
Subject to Damage from Weathering:
|
Severe
|
|
Frost line Depth:
|
30
|
|
Termite:
|
M to H
|
|
Decay:
|
S to M
|
|
Winter Design Temp:
|
8
|
|
Ice barrier required:
|
No
|
|
Flood Hazards:
|
Firm
|
|
Air Freezing Index:
|
1000
|
|
Mean annual temp:
|
55
|
9. Amend
Subsection R302.1 Exterior Walls: #2 to read: Cantilevered manufactured
fireplaces", add #6 "Roof Eave overhangs" and #7 "Uncovered decks".
(Copy from Jefferson County see Table R302.1 page 49)
10. Amend
Subsection R302.5.1 Opening protection by replacing 1 3/8 inches (35
mm) with 1 ¾ inches (45 mm). (Copy from Jefferson County, more
strict by making in 1 ¾)
11. Amend
Subsection R302.6 Dwelling/garage fire separation by replacing "The
garage shall be separated as required by Table R302.6" with "The garage
shall be separated by 5/8" fire code gypsum board, type X."
12. Amend
Subsection R303.4.2 Exhaust openings to read "Exhaust air shall not
be directed below 6 feet and 8 inches onto a walkway. (Copy from Jefferson
County)
13. Amend
Section R309.1 Floor surface by adding the following to the end of
this Section: "In private garage with end entry located beneath habitable
rooms, the floor shall be a minimum of four inches (4") lower than
the adjacent basement floor."
14. Add
Subsection R309.3.1 All floors "Minimum thickness of garage floors
shall be four inch (4") concrete with one-half inch (½") rebar
two foot (2') on center each way or 6" X 6" X 10" welded wire. The
above specifications shall also apply to carports and detached garages."
15. Add
Subsection R309.4.1 Pavilion: Pavilion structures shall be open on
at least two sides. If motorized equipment (vehicle, lawnmower, etc.)
are stored underneath, the structure becomes a "carport" and comes
under the provisions of Section 309.2. (Copy from Jefferson County)
16. Add
Subsection R309.5.1. Pre-Manufactured Accessory Structures Anchoring
System. Accessory structures must be anchored into the ground to sufficiently
withstand a 90 mph wind. There are three types of acceptable anchoring
systems other than a full foundation with frost-protected footing.
a. Slab. A minimum of four inch (4") concrete with
a four inch (4") subgrade of suitably compacted materials one-half
inch (½") anchor bolts placed six feet (6') on center with
three inch (3") minimum embedment in concrete.
b. Auger Tie Down. Similar to manufactured home tie
downs with a minimum of two per side — max spacing ten feet
(10') on center. See manufacturer's details on installation into the
ground.
c. Piers. Sheds built on 4 X 4 skids may be anchored
into a concrete pier system. Piers shall be 8" X 8" X 30" deep and
shall be spaced a maximum of eight feet (8') on center. Piers shall
be located directly under the structural floor frame of the shed.
17. Add
Subsection R309.5.2 Location. Pre-Manufactured structures shall be
located in accordance with the City of De Soto zoning regulations.
18. Add
Subsection R309.5.3 Accessory structures closer than ten feet (10')
to a habitable structure shall be protected with a one-hour fire partition.
19. Amend
Subsection R311.2 Egress door by replacing 32" and 78" with 36" and
80" respectively.
20. Add
Subsection 311.4.1. Interior passage doors shall have the minimum
width of two feet and six inches (2' 6").
Exception: Bathroom doors may be two feet four
inches (2' 4").
21.
Add Subsection R401.3.1 "Upon final inspection, if the yard
is not graded, seeded and straw placed due to inclement weather and
the title company has not escrowed monies for the grading, seeding
and placement of straw for the yard, then the City may require a refundable
deposit of two thousand dollars ($2,000.00) or a reasonable amount
determined by the City to ensure that the grading, seeding and placement
of straw is completed within a reasonable time."
[Ord. No. 4048 §1, 9-21-2015]
23. Amend
Subsection R403.1.1 Minimum size to read: "All footings shall have
a minimum of two (2) one-half inch (½") rebar. The minimum
size for all footings shall be eight inches (8") thick by sixteen
inches (16") wide. In one- and two-family dwellings the minimum footing
size shall be:
|
Slab and crawl space one story
|
8" x 16"
|
|
One story
|
8" x 20"
|
|
One and one-half story
|
8" x 22"
|
|
Two story
|
8" x 24"
|
|
Add two inches (2") for ten inch (10") walls
|
|
Add two inches (2") to the width of the footing when a log home
is built. In all other buildings, the footing shall be designed to
carry the load applied on it. All footings must have a key-way.
|
24. Amend
Section R403.1.4.1 Frost Protection by deleting item #2, item #3 and
exceptions. (Copy from Jefferson County, this keeps homeowners from
building light frame construction with no footing or pier)
25. Delete
Section R403.3. (Copy from Jefferson County, keep from allowing shallow
footings)
26. Add
Subsection R405.1 No ground water present: Provide drain tile, perforated
pipe, or other approved foundation drainage systems (such as water
channel system) around perimeter of the outside of the foundation
and inside the foundation. Drain discharge shall be by gravity to
daylight or be connected to a basement floor sump.
27. Add
Subsection R405.1.2 Filter Membranes: An approved filter membrane
shall be placed over the top of the joints/pipe perforations. The
tile/pipe shall be placed on 2" minimum gravel or crushed stone and
have 6" minimum cover.
28. Add
Subsection R405.1.4 Damp Proofing: Provide damp proofing of floor
slab with a 6 mil polyethylene film below slab, with joints in membrane
lapped a minimum of 6" and sealed.
29. Add
Subsection R405.2. Groundwater present: Provide drain tile, perforated
pipe or other approved foundation drainage system both inside and
outside of foundation.
30. Add
Subsection R405.2.1 Drainage System: Drainage system shall discharge
by gravity to daylight or be connected to an approved sump (18" in
diameter x 24" deep with fitted cover) having a sump pump that discharges
into an approved disposal system or to daylight. (All of the above
copy from Jefferson County)
31. Amend
Subsection R602.3 Design and construction by adding: Exception "#2
Headers can be on top of an opening in a wall". (Copy from Jefferson
County)
32. Amend
Subsection R602.3.1 Stud Spacing by replacing "spaced no more than
specified in Table R602.3(5) and Table R602.3.1" with "spaced no more
than 16 inches on center". (Copy from Jefferson County)
33. Amend
Table R602.3.1(1) Item #36 Description of Fastener by adding "or 1
1/8" screws, pan head or button head" and Item #37 Description of
Fastener by adding "or 1 ¼" screws, pan head or button head".
(Copy from Jefferson County)
34. Amend
Table R602.3(3) by replacing the number "24" under maximum stud spacing
with "16". (Copy from Jefferson County)
35. Delete
Subsection R602.5 Interior non-bearing walls.
36. Delete
Subsection R612.2 Window sills.
37. Delete
Subsection R612.3 Window fall prevention devices.
38. Delete
Subsection R612.4 Window opening limiting devices.
39. Delete
Subsection R612.4.1 General requirements.
40. Delete
Subsection R612.4.2 Operation for emergency escape.
41. Amend
Subsection R702.1 General adding: "The warm side of all exterior stud
framed walls except garages shall be drywalled and fire taped." as
the first sentence.
42. Amend
Subsection R905.2.8.2 Valleys Item #3 by replacing "one ply of smooth
roll roofing complying with ASTM D 6380 and at least 36 inches wide
(914 mm)" with "two ply of 15 lb. felt complying with ASTM D226 Type
I, ASTM D 4869 Type I, or ASTM D 6757".
43. Amend
Subsection N1102.2.3 Access hatches and doors by adding "Access doors
from conditioned spaces to unconditioned spaces shall be insulated
to a level equivalent to the insulation of the surrounding surfaces."
as the first sentence.
44. Amend
Subsection N1102.4.2 Air sealing and insulation by adding the words
"Where required by Code Official the" to the beginning of the first
sentence.
45. Delete
Section N1102.4.3 Fireplaces.
46. Amend
Subsection N1103.1.1 Programmable thermostat by deleting the last
sentence of the paragraph.
47. Amend
Subsection N1103.2.1 Insulation to read: "Supply ducts, in unconditioned
spaces, shall be insulated to a minimum of R-4."
48. Amend
Subsection N1103.2.2 Sealing by deleting #1 and #2, delete the last
sentence "Duct tightness shall be verified by either of the following"
and replace "Exception" with "Duct sealing and tightness test is not
required if the air handler and most ducts are located within conditioned
space."
49. Amend
Subsection M1305.1.4.1 Ground clearance by replacing 2 inches (50.8
mm) with 3 inches (76 mm).
50. Amend
Subsection M1411.6 Locking access port caps to read "Refrigerant circuit
access ports located outdoors shall be fitted with non-locking or
locking type tamper-resistant caps."
51. Amend
Table M1601.4.1 Joints and seams by adding "Joints of duct systems
shall be made substantially airtight in an unconditioned area by means
of tapes, mastics, liquid sealants, gasketing or other approved closure
systems." as the first sentence.
52. Add
Subsection M1602.1.1 Bedrooms: Every bedroom shall have a return air
system.
53. Amend
Subsection G2408.4 (305.7) Clearances from grade to read "Equipment
and appliances supported from the ground shall be level and firmly
supported on a concrete slab or other approved material extending
not less than 2 inches (50.8 mm) above the adjoining grade. Such support
shall be in accordance with the manufacturer's installation instructions.
Appliances suspended from the floor shall have a clearance of not
less than 6 inches (152 mm) from the adjoining grade."
54. Delete
Subsection P2503.6 Shower liner test.
55. Amend
Subsection P2603.6.1 Sewer depth by inserting the numbers 18" and
30" respectively.
56.
Add Subsection P2903.4.3 "Expansion
Tanks: Any system with a new or a replacement water heating apparatus
shall be provided with an approved, listed and adequately sized thermal
expansion device (expansion tank) installed within ten (10) feet of
and on the cold water supply to the water heater. The tank may be
installed in a vertical up, vertical down, or horizontal position
in accordance with the manufacturer's recommendation.
Exception:
1) Listed non-storage instantaneous heaters having an inside diameter
of not more than three (3") inches
2) Water heaters, 30 gallons or less, installed under counter or in
confined spaces in multi-family units, may use adequately sized mechanical
water hammer arrestors to provide for thermal expansion with the approval
of the authority having jurisdiction or his/her representative.
3) One- and two-family residences served by private well.
57. Delete
Subsection P2904.1.1 Required sprinkler locations.
58. Amend
Table P2905.4 Water Service Pipe by deleting "Type M and WM".
59. Amend
Subsection P3102.3 Size to read "Stack required: Every building in
which plumbing is installed shall have at least one stack the size
of which is not less than seventy-five percent (75%) of the required
size of the building drain. Such stack shall run undiminished in size."
60. Amend
Subsection P3103.1 Roof Extension by replacing 6 inches (152 mm) with
12 inches (304 mm).
61. Amend
Subsection P3103.2 Frost Closure by replacing 3 inches (76 mm) with
2 inches (50.8 mm).
63. Adopt
Appendix G, Swimming Pools, Spas, and Hot Tubs.
[Ord. No. 3718 §1, 1-22-2007; Ord. No. 3887 §1, 5-16-2011]
The International Mechanical Code is further amended and changed
in the following respects:
CHAPTER 1 (OF INTERNATIONAL MECHANICAL CODE)
The following Sections of the International Mechanical Code,
2009 Edition, are revised as follows:
1. Amend
Section 101.1 by inserting "City of De Soto, Missouri".
2. Amend
Section 103.2 by replacing the entire Section with: "The Building
Official, under the Code, shall be the City Manager or the duly authorized
representative of the City Manager."
3. Amend
Section 106.3.1 Construction Documents by deleting "when required
by state law".
4. Amend
Section 106.5.2 by inserting "$40.00".
5. Amend
Section 106.5.3 #2 to read: "Fifty percent (50%)" and deleting #3.
6. Amend Section 108.4 Violations penalties to read: See "Violation penalties" as provided in Section
500.020 of this ordinance.
7. Amend Section 109. Means of Appeal to read: See "Means of Appeal" as provided in Section
500.020 of this ordinance.
8. Amend
Section 301.7 Electrical by adding "2005 National Electrical Code".
[Ord. No. 3718 §1, 1-22-2007; Ord. No. 3887 §1, 5-16-2011]
The International Plumbing Code is further amended and changed
in the following respects:
CHAPTER 1 (OF INTERNATIONAL PLUMBING CODE)
The following Sections of the International Plumbing Code, 2009
Edition, are revised as follows:
1. Amend
Section 101.1 by inserting "City of De Soto, Missouri".
2. Amend
Section 103.2 by replacing the entire Section with: "The Building
Official, under the Code, shall be the City Manager or the duly authorized
representative of the City Manager."
3. Amend
Section 106.3.1 Construction Documents by deleting "when required
by state law".
4. Amend
Section 106.6.3 #2 to read "Fifty percent (50%)" and deleting #3.
5. Amend Section 109. Means of Appeal. See "Means of Appeal" as provided in Section
500.020 of this ordinance.
6. Amend
Section 305.6.1 by inserting "Eighteen inches (18") and T.B.A".
7. Amend
Section 406 Automatic Clothes Washer Subsection 406.3 by replacing
"three inches" with "two inches (2")" and deleting "or an approved
trench drain".
8. Add
Subsection 412.3.1 Floor Drain: A minimum of one floor drain shall
be required for all residential structures with basements.
9. Amend
Subsection 417.3 Shower waste outlet by replacing "1½ inch"
with "two inches (2")".
10. Amend
Subsection 604.9.1 to read: "Air chambers, a minimum of sixteen inches
(16") long may be installed in lieu of water hammer arrestors."
11. Amend
Section 606.2 "Item #1" to read: "On the fixture supply to each fixture
in one- and two-family and multi-family residential occupancies, and
other than in individual guest rooms that are provided with unit shutoff
valves in hotels, motels, boarding houses, and similar occupancies."
12. Add
Subsection 703.6 "Minimum size building sewers" to read: "The gravity
building sewer shall not be less than four inches (4") in size."
13. Amend
Section 705.8.2 by deleting the word "purple" in this Section and
anywhere referenced when associated with the word "primer" where it
appears in the 2009 International Plumbing Code.
14. Amend
Section 710 Drainage Systems Sizing Table 710.1(1) Building Drains
and Sewers by adding Footnote B "The minimum size of the main building
drain shall be four inches (4")." and by adding Footnote C: "The maximum
developed length of underground two inch (2") diameter pipe shall
be twenty feet (20')".
15. Amend
Section 916.1 Vent Pipe Sizing by replacing "one-half" with "75%".
16. Amend
Section 904.1 by inserting twelve inches (12").
17. Amend
Subsection 904.2 Frost Closure by replacing "3" inches (76 mm) with
"two inches (50.8 mm)".
[Ord. No. 3718 §1, 1-22-2007; Ord. No. 3887 §1, 5-16-2011]
The International Energy Conservation Code is further amended
and changed in the following respects:
CHAPTER 1 (OF INTERNATIONAL ENERGY CODE)
The following Sections of the International Energy Code, 2009
Edition, are revised as follows:
1. Amend
Section 101.1 by inserting "City of De Soto, Missouri".
[Ord. No. 3718 §1, 1-22-2007; Ord. No. 3887 §1, 5-16-2011]
The International Fuel Conservation Code is further amended
and changed in the following respects:
CHAPTER 1 (OF INTERNATIONAL FUEL CODE)
The following Sections of the International Fuel Gas Code, 2009
Edition, are revised as follows:
1. Amend
Section 101.1 by inserting "City of De Soto, Missouri".
[Ord. No. 3718 §1, 1-22-2007; Ord. No. 3887 §1, 5-16-2011]
The International Urban-Wildland Interface Code is further amended
and changed in the following respects:
CHAPTER 1 (OF INTERNATIONAL URBAN-WILDLAND INTERFACE CODE)
The following Sections of the International Urban-Wildland Interface
Code, 2009 Edition, are revised as follows:
1. Section
101.1 by inserting "City of De Soto, Missouri".
[Ord. No. 4138, 11-19-2018; Ord. No. 4527, 3-18-2019]
A. The International Property Maintenance Code is amended and changed
in the following respects:
1.
Amend Section 101.1 to insert "City of De Soto, Missouri" in
place of "[NAME OF JURISDICTION]."
2.
Amend Section 103.2 by replacing the entire Section with "103.2
Appointment. The CODE OFFICIAL, under the Code, shall be the City
Manager or the duly authorized representative of the City Manager."
3.
Amend Section 103.5 Fees by replacing "as indicated in the following schedule [JURISDICTION TO INSERT APPROPRIATE SCHEDULE.]" with "as set forth in Section
500.020 of the City's Code."
4.
Amend Section 111 Means of appeal to read: "Any person aggrieved
by a decision of the Code Official shall have the right to appeal
that decision as set forth in Section 500.020.9 of the City's
Code."
5.
Section 112.4 Failure to comply shall be amended to read as
follows: "Any person who shall continue any work after having been
served with a stop-work order, except such work as that person is
directed to perform to remove a violation or unsafe condition, shall
be liable to a fine as set forth in Section 500.035 of the City's
Code."
6.
Amend Section 201.3 Terms defined in other codes to replace
the words "International Zoning Code" with "ordinances of the City
of De Soto."
7.
Amend Section 302.4 Weeds to replace "(jurisdiction to insert
height in inches)" with "seven (7) inches."
8.
Amend Section 304.14 Insect screens to replace "[DATE] to [DATE]"
with "January 1 to December 31."
9.
Amend Section 602.3 Heat supply to replace "[DATE] to [DATE]"
with "October 1 to March 30."
10.
Amend Section 602.4 Occupiable work spaces to replace "[DATE]
to [DATE]" with "October 1 to March 30."
11.
Add Subsection 606.1.1 State certification. Any elevator, conveying
system or component for which a current State operating certificate
has been issued shall satisfy the requirements of this Section.
12.
Add Subsection 606.1.2 Operation prohibited. The operation of
any elevator, conveying system or component for which a current State
operating certificate has not been issued shall be prohibited.
13.
Amend Chapter 8 to replace the term "International Zoning Code"
with "the Code of the City of DeSoto, Missouri."
14.
Add Subsection 605.2.1 Ground-fault circuit-interrupter protection.
Ground-fault circuit-interrupter protection shall meet the requirements
of the currently adopted National Electric Code.
15.
Add Subsection 703.3 Dwelling-garage fire separation. Where
a garage was built either attached to or under a dwelling and no fire
separation was required at the time of construction, the garage shall
meet one of the following options;
1. Meet the fire separation requirements of the
currently adopted International Residential Code.
|
2. Remove the garage door.
|
3. Install smoke alarms meeting the requirements
of new construction per the currently adopted International Residential
Code. Locations required shall include the garage area.
|
4. Install battery-powered wireless interconnected
smoke alarms in all locations required in Section 704.2, including
the garage area.
|
16.
Add Section 310 CARBON MONOIXDE ALARMS.
17.
Add Subsection 310.1 Carbon monoxide alarms. An approved carbon
monoxide alarm shall be installed outside of each separate sleeping
area in the immediate vicinity of the bedrooms in dwelling units within
which fuel-fired appliances exist and in dwelling units that have
attached garages.
18.
Add Subsection 310.2 Alarm requirements. Single-station carbon
monoxide alarms shall be listed as complying with UL 2034 and shall
be installed in accordance with this Code and the manufacturer's
installation instructions.
[Ord. No. 3718 §1, 1-22-2007]
A. Any
new construction or major structural renovation begun after January
1, 1991, all buildings for which leases are executed by political
subdivision of the State after January 1, 1994 and all buildings for
which leases are executed by the State or any institution of higher
education after January 1, 1994 shall comply with the standards for
seismic design and construction of the Building Officials and Code
Administrators Code or of the Uniform Building Code.
B. This
Section shall not apply to any building owned by the State, any institution
of higher education, any political subdivision upon which construction
was begun or finished before December 17, 1990, any private structure
with less than ten thousand (10,000) square feet in total area or
any single-family or duplex residence.
C. As
used in this Section, the term "major structural renovation" means any reconstruction, rehabilitation, addition or other improvement
of an existing structure, the cost of which equals or exceeds fifty
percent (50%) of the market value of the structure before the start