The Borough of Clayton utilizes shallow wells for a portion of its municipal public water supply. The one shallow well currently in use is located at the North Delsea water tower site. The well, known as Well Number 6, is located in the Cohansey-Kirkwood aquifer and is approximately 74 feet deep. Any development within 1,100 feet of this and future wells must be developed in compliance with the New Jersey Clean Water Act, N.J.A.C. 7:10, as amended, and with the following additional standards to protect these community resources. (The Zoning Map identifies these well protection areas.) Developers and property owners are encouraged to use cooperative approaches to subdivision and site design, especially for stormwater management, and to meet with the Water and Sewer Utility and its engineers prior to submitting any applications.
A. Structures.
(1) No structure shall be located within 250 feet of the well.
(2) Facilities of any type, buildings, tanks, platforms, etc., located outside of industrial or commercial structures, and proposed for the storage of fuels, chemicals or any substances which could endanger groundwater resources, shall be prohibited within 1,100 feet of a well unless a containment system designed to hold the entire contents of the facility is provided and approved by the Board and Water and Water and Sewer Utility engineers. When an approved containment system is provided, these facilities may be located within 500 feet of the well.
B. Lot coverage.
(1) Maximum building coverage (includes all principal and accessory buildings): 30%.
(2) Maximum impervious coverage: 50%.
C. Parking lots or driveways. No parking lots or driveways shall be located within 200 feet of the well.
D. Stormwater facilities.
(1) No detention or retention facility, dry well or other stormwater holding system shall be located within 1,100 feet of a well.
(2) The outflow from a detention or retention basin, whether through a piped system or overland, shall be located more than 1,100 feet from a well.
(3) No swale designed for carrying stormwater shall be located with 500 feet of the well.
E. Sanitary sewage facilities.
(1) Sanitary sewer lines, manholes and pumping stations shall be located no closer than 200 feet to a well.
(2) Settling basins for any type of residential or nonresidential effluent shall not be located within 1,100 feet of a well.
(3) No septic system used for domestic waste shall be located within 500 feet of a well. Nonresidential septic systems are prohibited within 1,100 feet of a well.