Table 2.1: Minimum Vision Clearance Triangle
| ||
---|---|---|
Right-of-Way Width
(feet)
|
Distance from Right-of-Way Intersection
(feet)
| |
Less than 66
|
15
| |
76 to 99
|
20
| |
More than 99
|
25
|
Table 2.2: Surfacing Standards for Driveways and Parking
Areas
| |||||
---|---|---|---|---|---|
Asphalt
|
Concrete
| ||||
Surface
(inches)
|
Base
(inches)
|
Surface
(inches)
|
Base
(inches)
| ||
Driveways, one- and two-family
|
2
|
4
|
4
|
4
| |
Parking lots, commercial and multifamily
|
3
|
8
|
6
|
4
| |
Loading areas and drives, commercial
|
4
|
8
|
7
|
4
| |
Loading areas and drives, industrial
|
4
|
10
|
7
|
4
|
Table 2.3: Recommended Minimum Parking Lot Layout Dimensions
| |||||
---|---|---|---|---|---|
Parking Angle in Degrees
| |||||
Minimum Permitted Dimensions
|
0° (parallel)
|
45°
|
60°
|
90°
| |
(feet)
| |||||
Stall width at parking angle (SW)
|
9
|
9
|
9
|
9
| |
Stall width parallel to aisle (WP)
|
18
|
12.7
|
10.4
|
9
| |
Stall depth to wall (D)
|
91
|
17.51
|
191
|
18.51
| |
Stall length (SL)
|
—
|
19.8
|
21
| ||
Aisle width (AW)
|
122
|
122
|
152
|
24
| |
Throat length (right-of-way to parking area) (T)
|
Refer to requirements in § 660-39
| ||||
Wall to wall (single-loaded) (W1)
|
21
|
29.5
|
34
|
42.5
| |
Wall to wall (double-loaded) (W2)
|
32
|
47
|
53
|
61
|
NOTES:
| ||
---|---|---|
1
|
Parking spaces located behind an enclosed garage and located
directly off a through aisle shall be at least 30 feet deep.
| |
2
|
This dimension represents (AW) for one-way traffic. For two-way
traffic, add 8.0 feet to a maximum (AW) of 24.0 feet.
|
Table 2.4: Specific Off-Street Parking Requirements
| |||
---|---|---|---|
Uses
|
Minimum Required Spaces
|
Minimum Required On-Site Queuing
|
Other Required Off-Street Parking Standards
|
Commercial/Retail
| |||
Auto agency (sales)
|
1.0 per 500 SF
|
Plus 3.0 per service bay and additional space for public display
as required if outside display is permitted
| |
Auto fuel station #1 (w/o service)
|
2.0 minimum
|
Plus 4.75 per 1,000 retail SF
| |
Auto fuel station #2 (w/ service)
|
3.0 minimum
|
Plus 3.0 per service bay
| |
Auto fuel station #3 (w/ convenience store)
|
Station #1 or #2 requirements
|
Plus 1.0 per 200 SF
| |
Auto fuel station (w/ car wash)
|
Station #1 or #2 requirements
|
Equal to 3 times car wash capacity
| |
Auto parts (tire/battery/acc.)
|
4.75 per 1,000 SF
| ||
Auto service station
|
3.0 minimum
|
Plus 3.0 per service bay
| |
Barber/beauty salon
|
3.0 per licensed chair
| ||
Building materials/home improvement center
|
4.75 per 1,000 SF
| ||
Car wash (full service)
|
1.0 per 200 SF of office space
|
Equal to 8 times car wash capacity
|
Plus 1.0 per employee on largest shift
|
Car wash (self service)
|
4.0 cars per wash stall
| ||
Car wash (accessory)
|
Equal to 3 times car wash capacity
| ||
Commercial or retail sales uses (except as herein noted)
|
4.75 per 1,000 SF
| ||
Commercial vegetable and flower gardening, plant nurseries and
greenhouses
|
2.0 per 3 employees on maximum shift
|
Plus 1.0 per vehicle used or stored plus 5.0 per 1,000 SF retail
floor area
| |
Equipment sales, service, rental and repair
|
1.0 per 250 SF
| ||
Furniture store
|
2.5 per 1,000 SF
| ||
General merchandise and department store < 5,000 SF
|
5.0 per 1,000 SF
| ||
General merchandise and convenience store >5,000 SF
|
4.75 per 1,000 SF
| ||
Hardware, paint, home improvement store
|
4.0 per 1,000 SF
| ||
Laundry and dry cleaning (drop-off/pick-up)
|
4.0 per 1,000 SF
| ||
Laundry (self service)
|
1.0 per 2 washers
| ||
Paint store
|
3.0 per 1,000 SF
| ||
Plumbing, air-conditioning and heating equipment (sales, service,
warehousing)
|
3.0 per 1,000 SF sales and office area stored
|
Plus 2.0 per 3 employees on maximum shift; plus 1.0 per vehicle
stored on site
| |
Restaurant, dine-in (quality, gourmet, family)
|
1.0 per 3 seats
|
Plus 2.0 per 3 employees on maximum shift; 10.0 minimum
| |
Restaurant, dine-in, fast food (w/o drive-through)
|
1.0 per 2 seats
|
Plus 2.0 per 3 employees on maximum shift
| |
Restaurant, fast food (w/ drive-through)
|
1.0 per 2 seats
|
8.0 per drive-up window with 3 spaces minimum at ordering station
|
Plus 2.0 per 3 employees on maximum shift
|
Shopping center (w/ supermarket)
|
5.5 per 1,000 SF
| ||
Shopping center (w/o supermarket)
|
5.0 per 1,000 SF
| ||
Shopping center (3+ stores, not classified elsewhere in table)
|
5.0 per 1,000 SF
| ||
Specialty retail center (average tenant space < 2,500 SF)
|
4.0 per 1,000 SF
| ||
Specialty store
|
4.0 per 1,000 SF
| ||
Supermarket, grocery
|
6.0 per 1,000 SF
| ||
Taxidermist
|
2.0 per 1,000 SF
| ||
Tavern, bar, cocktail lounge
|
1.0 per 2.5 seats
|
Plus 1.5 per employee on maximum shift
| |
Truck service center and repair facility
|
1.0 per employee
|
Plus 2.0 truck spaces per each stall
| |
Video tape rental/sales
|
5.5 per 1,000 SF
| ||
Residential
| |||
Apartment
|
2.0 per unit of which 1 must be enclosed
|
Plus 0.5 per unit for visitors
| |
Caretaker's residence
|
1.0 per bedroom
| ||
Condominium
|
2.0 per unit of which 1 must be enclosed
|
Plus 0.5 per unit for visitors
| |
Dormitories or group living facilities (CBRFs)
|
0.5 per bedroom
| ||
Dwellings (single-family detached)
|
2.0 per dwelling
| ||
Dwellings (two-family/duplex)
|
2.0 per unit of which 1 must be enclosed
|
Plus 0.5 per unit for visitors
| |
Group homes
|
0.25 per bed
|
Plus 1.0 per employee on maximum shift
| |
Rectory
|
1.0 per bedroom
| ||
Residential units in nonresidential structures
|
1.0 per bedroom
| ||
Senior citizen multiple-family/retirement community
|
0.5 per unit
|
Consider 1.0 per unit reserved for future conversion to conventional
multiple-family
| |
Transportation/Communication/Utilities:
| |||
Airports/heliports/landing strips
|
2.0 per 3 employees on maximum shift
|
Plus 1.0 per vehicle used or stored; plus 1.0 per 200 SF lobby
area
| |
Radio, TV and other communication facilities
|
2.0 per employee on maximum shift
|
Plus 1.0 per vehicle used or stored
| |
Institutional:
| |||
Child-care centers/day nurseries
|
1.0 per employee
|
Plus 1.0 per 10 children
| |
Churches/chapels
|
1.0 per 3 seats
|
Plus 1.0 per vehicle used or stored on premises
| |
Clubs and lodges
|
1.0 per 4 seats; or 1.0 per 3 members, whichever is greater
| ||
Hospitals
|
0.75 spaces per bed
| ||
Kennels
|
2.0 per 3 employees on maximum shift
|
Plus 1.0 per vehicle used or stored
| |
Museums/galleries
|
2.5 per 1,000 SF gross floor area
| ||
Nursing homes
|
0.75 per bed
|
5 vehicles on site
| |
Postal stations
|
4.0 per customer service station
|
Plus 2.0 per 3 employees on maximum shift; Plus 1.0 per vehicle
stored on site
| |
Schools (preschools)
|
1.0 per employee
|
Plus 1.0 per 10 children
| |
Schools (elementary schools)
|
1.0 per classroom and 4.5 per 1,000 SF office
|
8 vehicles
| |
Schools (middle schools)
|
1.0 per classroom and 4.5 per 1,000 SF office
|
8 vehicles
| |
Schools (high schools)
|
1.0 per classroom and 4.5 per 1,000 SF office
|
8 vehicles
|
Plus 1.0 per 3 students
|
Schools (special education)
|
1.0 per classroom and 4.5 per 1,000 SF office
|
8 vehicles
| |
Schools (vocational)
|
1.0 per classroom and 4.5 per 1,000 SF office
|
Plus 1.0 per 2 students
| |
Schools (college, university)
|
1.0 per employee
|
Plus 1.0 per 2 students
| |
Cultural/Entertainment/Recreational
| |||
Arcades/amusement places
|
5.0 per 1,000 SF
|
Plus 1.0 per 2 games
| |
Athletic fields
|
60 per 1 facility (field, diamond); 100 per 2 facilities
| ||
Auditoriums/meeting rooms/places for public assembly (except
as noted herein)
|
1.0 per 3 seats or 1.0 per 50 SF floor area of assembly area
where there is no fixed seating
| ||
Bowling alleys
|
5.0 per alley
| ||
Cemeteries
|
2.0 per 3 employees on maximum shift
|
Plus 1.0 garage space per vehicle used or stored
| |
Clubs/lodges, open to public
|
1.0 per 2.5 seats
|
Plus 2.0 per 3 employees on maximum shift
| |
Community centers and private, nonprofit recreation centers
(except as noted)
|
4.0 per 1,000 SF
|
5 vehicles on site
|
Plus 1.0 per employee on maximum shift
|
Dance studio, martial arts studio
|
5.0 per 1,000 SF
| ||
Golf/country clubs
|
To be determined by Plan Commission based upon report prepared
by applicant
| ||
Golf courses
|
3.0 per hole
|
Plus spaces equal to 30% total licensed seating capacity of
buildings
| |
Golf driving ranges
|
2.0 per tee
| ||
Golf, miniature
|
1.0 per 5,000 SF lot area
| ||
Gymnasiums
|
3.0 per 1,000 SF
| ||
Handball/racquetball courts
|
3.0 per court
| ||
Ice and roller rinks
|
5.5 per 1,000 SF
| ||
Parks (City/county/state), playgrounds and picnic grounds
|
To be determined by Parks Board
| ||
Sports club/health spa
|
7.0 per 1,000 SF
| ||
Swimming pools
|
3.0 per 1,000 SF
|
Plus 1.0 per employee
| |
Tennis clubs
|
3.0 per 1,000 SF
|
Plus 1.0 per 4 spectator seats
| |
Tennis courts, outdoor
|
3.0 per court
|
Plus 1.0 per 4 spectator seats
| |
Theater, live
|
1.0 per 50 SF
| ||
Theater, music
|
1.0 per 50 SF
| ||
Theater, movie
|
0.50 per seat
| ||
Industrial
| |||
Concrete or asphalt batch plant
|
1.0 per employee
|
1.0 per vehicle stored on site
| |
Light industry
|
2.0 per 1,000 SF office/customer use
|
Plus 1.0 per 750 SF other or per vehicle used/stored
| |
Manufacturing and fabrication
|
2.0 per 1,000 SF office/customer use
|
Plus 1.5 per employee on maximum shift and 1.0 per company vehicle
stored on site
| |
Plumbing, air-conditioning and heating equipment (sales, service,
warehousing)
|
2.0 per 1,000 SF office/retail use
|
Plus 1.0 per 750 SF other or per vehicle used/stored
| |
Warehousing and wholesaling
|
2.0 per 3 employees on maximum shift
|
Plus 1.0 per vehicle used/stored but no less than 1/2,000 SF
| |
Office
| |||
Dental offices and clinics
|
4.5 per 1,000 SF
| ||
Medical office building or clinic
|
6.0 per 1,000 SF floor area or 5.0 per doctor, whichever is
greater
| ||
Office building, general
|
Maximum 4.5 per 1,000 gross SF to minimum 4.0 per 1,000 net
SF based upon floor plan utilization report approved by Plan Commission
with maximum of 20% of gross SF to be considered unleasable space
under a net square foot analysis
| ||
Research center (nonleasable space)
|
3.0 per 1,000 SF up to 50,000 SF
|
Plus 2.5 per 1,000 SF over 50,000 SF
| |
Services
| |||
Financial: bank (walk-in only)
|
4.5 per 1,000 SF
| ||
Financial: bank (drive-up and walk-in)
|
4.5 per 1,000 SF
|
Equal to 5 times drive up capacity
| |
Financial: lending agency, stockbroker
|
4.0 per 1,000 SF
| ||
Hotels, motels
|
1.0 per sleeping unit
|
Plus 2.0 per 3 employees on maximum shift; Plus 1.0 per vehicle
used or stored
| |
Insurance agents/brokers
|
4.0 per 1,000 SF
| ||
Mortuaries/funeral homes
|
1.0 per 5 seats; 10 minimum
| ||
Real estate agents/brokers
|
4.5 per 1,000 SF
| ||
Veterinary clinics and hospitals
|
6.0 minimum
|
Plus 4.0 per each exam room over 1 room
|
Table 2.5: Minimum Off-Street Loading Berth Requirements
| ||||
---|---|---|---|---|
Floor Area of Establishment
(square feet)
|
Required Number
|
Minimum Size
(feet)
|
Minimum Vertical Clearance
(feet)
| |
0 to 10,000
|
1
|
10 x 25
|
12
| |
10,001 to 25,000
|
2
|
10 x 40
|
12
| |
25,001 to 40,000
|
3
|
10 x 50
|
15
| |
40,001 to 100,000
|
4
|
10 x 60
|
15
| |
Over 100,000
|
5*
|
10 x 60
|
15
|
NOTES:
| ||
*
|
Plus one additional space for every 25,000 square feet of floor
area over 150,000.
|