[Ord. 2014-02, 8/18/2014]
1. Alteration or Relocation of Watercourse.
A. No encroachment, alteration, or improvement of any kind shall be
made to any watercourse until all adjacent municipalities which may
be affected by such action have been notified by the municipality,
and until all required permits or approvals have first been obtained
from the Department of Environmental Protection Regional Office.
B. No encroachment, alteration, or improvement of any kind shall be
made to any watercourse unless it can be shown that the activity will
not reduce or impede the flood-carrying capacity of the watercourse
in any way.
C. In addition, FEMA and the Pennsylvania Department of Community and
Economic Development shall be notified by the applicant prior to any
alteration or relocation of any watercourse.
2. When a community proposes to permit the following encroachments:
any development that causes a rise in the base flood elevations within
the floodway; or any development occurring in Zones A1-30 and Zone
AE without a designated floodway, which will cause a rise of more
than one foot in the base flood elevation; or alteration or relocation
of a stream (including but not limited to installing culverts and
bridges), the applicant shall (as per 44 CFR 65.12):
A. Apply to FEMA for conditional approval of such action prior to permitting
the encroachments to occur.
B. Upon receipt of the Administrator's conditional approval of
map change and prior to approving the proposed encroachments, a community
shall provide evidence to FEMA of the adoption of floodplain management
ordinances incorporating the increased base flood elevations and/or
revised floodway reflecting the post-project condition.
C. Upon completion of the proposed encroachments, a community shall
provide as-built certifications. FEMA will initiate a final map revision
upon receipt of such certifications in accordance with 44 CFR 67.
3. Any new construction, development, uses or activities allowed within
any identified floodplain area shall be undertaken in strict compliance
with the provisions contained in this Chapter and any other applicable
codes, ordinances and regulations.
[Ord. 2014-02, 8/18/2014]
1. Residential Structures.
A. In AE, A1-30, and AH Zones, any new construction or substantial improvement
shall have the lowest floor (including basement) elevated up to, or
above, the regulatory flood elevation.
B. In A Zones, where there are no Base Flood Elevations specified on the FIRM, any new construction or substantial improvement shall have the lowest floor (including basement) elevated up to, or above, the regulatory flood elevation determined in accordance with §
8-402, Subsection 1C, of this Chapter.
C. The design and construction standards and specifications contained
in the 2009 International Building Code (IBC) and in the 2009 International
Residential Code (IRC), or the most recent revisions thereof, and
ASCE 24 and 34 Pa. Code (Chapters 401–405, as amended), shall
be utilized where they are more restrictive.
2. Nonresidential Structures.
A. In AE, A1-30 and AH Zones, any new construction or substantial improvement
of a nonresidential structure shall have the lowest floor (including
basement) elevated up to, or above, the regulatory flood elevation,
or be designed and constructed so that the space enclosed below the
regulatory flood elevation:
(1)
Is floodproofed so that the structure is watertight with walls
substantially impermeable to the passage of water; and
(2)
Has structural components with the capability of resisting hydrostatic
and hydrodynamic loads and effects of buoyancy.
B. In A Zones, where no base flood elevations are specified on the FIRM, any new construction or substantial improvement shall have the lowest floor (including basement) elevated or completely floodproofed up to, or above, the regulatory flood elevation determined in accordance with §
8-402, Subsection 1C, of this Chapter.
C. Any nonresidential structure, or part thereof, made watertight below
the regulatory flood elevation shall be floodproofed in accordance
with the W1 or W2 space classification standards contained in the
publication entitled "Flood-Proofing Regulations" published by the
U.S. Army Corps of Engineers (June 1972, as amended March 1992), or
with some other equivalent standard. All plans and specifications
for such floodproofing shall be accompanied by a statement certified
by a registered professional engineer or architect which states that
the proposed design and methods of construction are in conformance
with the above-referenced standards.
D. The design and construction standards and specifications contained
in the 2009 International Building Code (IBC) and in the 2009 International
Residential Code (IRC), or the most recent revisions thereof, and
ASCE 24 and 34 Pa. Code (Chapters 401–405, as amended), shall
be utilized where they are more restrictive.
3. Space Below the Lowest Floor.
A. Fully enclosed space below the lowest floor (excluding basements)
which will be used solely for the parking of a vehicle, building access,
or incidental storage in an area other than a basement, shall be designed
and constructed to allow for the automatic entry and exit of floodwaters
for the purpose of equalizing hydrostatic forces on exterior walls.
The term "fully enclosed space" also includes crawl spaces.
B. Designs for meeting this requirement must either be certified by
a registered professional engineer or architect, or meet or exceed
the following minimum criteria:
(1)
A minimum of two openings having a net total area of not less
than one square inch for every square foot of enclosed space.
(2)
The bottom of all openings shall be no higher than one foot
above grade.
(3)
Openings may be equipped with screens, louvers, or other coverings
or devices, provided that they permit the automatic entry and exit
of floodwaters.
4. Historic Structures. Historic structures undergoing repair or rehabilitation
that would constitute a substantial improvement, as defined in this
Chapter, must comply with all ordinance requirements that do not preclude
the structure's continued designation as a historic structure.
Documentation that a specific Chapter requirement will cause removal
of the structure from the National Register of Historic Places or
the State Inventory of Historic places must be obtained from the Secretary
of the Interior or the State Historic Preservation Officer. Any exemption
from Chapter requirements will be the minimum necessary to preserve
the historic character and design of the structure.
[Ord. 2014-02, 8/18/2014]
1. The following minimum standards shall apply for all construction
and development proposed within any identified floodplain area:
A. Fill. If fill is used, it shall:
(1)
Extend laterally at least 15 feet beyond the building line from
all points;
(2)
Consist of soil or small rock materials only. Sanitary landfills
shall not be permitted;
(3)
Be compacted to provide the necessary permeability and resistance
to erosion, scouring, or settling;
(4)
Be no steeper than one vertical to two horizontal feet unless
substantiated data justifying steeper slopes are submitted to, and
approved by the Floodplain Administrator; and
(5)
Be used to the extent to which it does not adversely affect
adjacent properties.
B. Drainage Facilities. Storm drainage facilities shall be designed
to convey the flow of stormwater runoff in a safe and efficient manner.
The system shall ensure proper drainage along streets and provide
positive drainage away from buildings. The system shall also be designed
to prevent the discharge of excess runoff onto adjacent properties.
C. Water and Sanitary Sewer Facilities and Systems.
(1)
All new or replacement water supply and sanitary sewer facilities
and systems shall be located, designed and constructed to minimize
or eliminate flood damages and the infiltration of floodwaters.
(2)
Sanitary sewer facilities and systems shall be designed to prevent
the discharge of untreated sewage into floodwaters.
(3)
No part of any on-site waste disposal system shall be located
within any identified floodplain area except in strict compliance
with all state and local regulations for such systems. If any such
system is permitted, it shall be located so as to avoid impairment
to it, or contamination from it, during a flood.
(4)
The design and construction provisions of the UCC and FEMA #348,
"Protecting Building Utilities From Flood Damages," and "The International
Private Sewage Disposal Code" shall be utilized.
D. Other Utilities. All other utilities such as gas lines, electrical
and telephone systems shall be located, elevated (where possible)
and constructed to minimize the chance of impairment during a flood.
E. Streets. The finished elevation of all new streets shall be no more
than one foot below the regulatory flood elevation.
F. Storage. All materials that are buoyant, flammable, explosive, or in times of flooding, could be injurious to human, animal, or plant life, and not listed in §
8-504, Development Which May Endanger Human Life, shall be stored at or above the regulatory flood elevation or floodproofed to the maximum extent possible.
G. Placement of Buildings and Structures. All buildings and structures
shall be designed, located, and constructed so as to offer the minimum
obstruction to the flow of water and shall be designed to have a minimum
effect upon the flow and height of floodwater.
H. Anchoring.
(1)
All buildings and structures shall be firmly anchored in accordance
with accepted engineering practices to prevent flotation, collapse,
or lateral movement.
(2)
All air ducts, large pipes, storage tanks, and other similar
objects or components located below the regulatory flood elevation
shall be securely anchored or affixed to prevent flotation.
I. Floors, Walls and Ceilings.
(1)
Wood flooring used at or below the regulatory flood elevation
shall be installed to accommodate a lateral expansion of the flooring
perpendicular to the flooring grain without causing structural damage
to the building.
(2)
Plywood used at or below the regulatory flood elevation shall
be of a "marine" or "water-resistant" variety.
(3)
Walls and ceilings at or below the regulatory flood elevation
shall be designed and constructed of materials that are water-resistant
and will withstand inundation.
(4)
Windows, doors, and other components at or below the regulatory
flood elevation shall be made of metal or other water-resistant material.
J. Paints and Adhesives.
(1)
Paints and other finishes used at or below the regulatory flood
elevation shall be of marine or water-resistant quality.
(2)
Adhesives used at or below the regulatory flood elevation shall
be of a marine or water-resistant variety.
(3)
All wooden components (doors, trim, cabinets, etc.) used at
or below the regulatory flood elevation shall be finished with a marine
or water-resistant paint or other finishing material.
K. Electrical Components.
(1)
Electrical distribution panels shall be at least three feet
above the base flood elevation.
(2)
Separate electrical circuits shall serve lower levels and shall
be dropped from above.
L. Equipment. Water heaters, furnaces, air-conditioning and ventilating
units, and other electrical, mechanical or utility equipment or apparatus
shall not be located below the regulatory flood elevation.
M. Fuel Supply Systems. All gas and oil supply systems shall be designed
to prevent the infiltration of floodwaters into the system and discharges
from the system into floodwaters. Additional provisions shall be made
for the drainage of these systems in the event that floodwater infiltration
occurs.
N. Uniform Construction Code Coordination. The Standards and Specifications
contained 34 Pa. Code (Chapters 401–405), as amended, and not
limited to the following provisions, shall apply to the above and
other sections and subsections of this Chapter, to the extent that
they are more restrictive and supplement the requirements of this
Chapter.
(1) International
Building Code (IBC) 2009 or the latest edition thereof: Secs. 801,
1202, 1403, 1603, 1605, 1612, 3402, and Appendix G.
(2) International
Residential Building Code (IRC) 2009 or the latest edition thereof:
Secs. R104, R105, R109, R322, Appendix E, and Appendix J.
[Ord. 2014-02, 8/18/2014]
1. Within any identified floodplain area, any structure of the kind described in Subsection 1A, below, shall be prohibited. If a variance is obtained in accordance with the criteria in Part
8, then the following provisions apply:
A. In accordance with the Pennsylvania Flood Plain Management Act, and
the regulations adopted by the Department of Community and Economic
Development as required by the Act, any new or substantially improved
structure which: will be used for the production or storage of any
of the following dangerous materials or substances; or, will be used
for any activity requiring the maintenance of a supply of more than
550 gallons, or other comparable volume, of any of the following dangerous
materials or substances on the premises; or, will involve the production,
storage, or use of any amount of radioactive substances; shall be
subject to the provisions of this Section, in addition to all other
applicable provisions. The following list of materials and substances
are considered dangerous to human life:
(11)
Nitric acid and oxides of nitrogen.
(12)
Petroleum products (gasoline, fuel oil, etc.).
(16)
Sulphur and sulphur products.
(17)
Pesticides (including insecticides, fungicides, and rodenticides).
(18)
Radioactive substances, insofar as such substances are not otherwise
regulated.
B. Within any identified floodplain area, any new or substantially improved
structure of the kind described in Subsection 1A, above, shall be
prohibited within the area measured 50 feet landward from the top-of-bank
of any watercourse.
C. Within any floodway area, any structure of the kind described in Subsection 1A, above, shall be prohibited. Where permitted within any identified floodplain area, any new or substantially improved residential structure of the kind described in Subsection 1A, above, shall be elevated to remain completely dry up to at least 1 1/2 feet above base flood elevation and built in accordance with §§
8-501,
8-502 and
8-503.
D. Where permitted within any identified floodplain area, any new or substantially improved nonresidential structure of the kind described in Subsection
1)above, shall be built in accordance with §
8-501,
8-502 and
8-503, including:
(1)
Elevated, or designed and constructed to remain completely dry
up to at least 1 1/2 feet above base flood elevation; and
(2)
Designed to prevent pollution from the structure or activity
during the course of a base flood.
E. Any such structure, or part thereof, that will be built below the
regulatory flood elevation shall be designed and constructed in accordance
with the standards for completely dry floodproofing contained in the
publication "Flood-Proofing Regulations (U.S. Army Corps of Engineers,
June 1972, as amended March 1992), or with some other equivalent watertight
standard.
[Ord. 2014-02, 8/18/2014]
All subdivision proposals and development proposals containing
at least 50 lots or at least five acres, whichever is the lesser,
in identified floodplain areas where base flood elevation data are
not available, shall be supported by hydrologic and hydraulic engineering
analyses that determine base flood elevations and floodway information.
The analyses shall be prepared by a licensed professional engineer
in a format required by FEMA for a Conditional Letter of Map Revision
and Letter of Map Revision. Submittal requirements and processing
fees shall be the responsibility of the applicant.
[Ord. 2014-02, 8/18/2014]
1. Within any identified floodplain area, manufactured homes shall be
prohibited. If a variance is obtained in accordance with the criteria
in Part 8, then the following provisions apply .Within any Floodway
Area/District, manufactured homes shall be prohibited. If a variance
is obtained in accordance with the criteria in Part 8, then the following
provisions apply:
A. Within any identified floodplain area, manufactured homes shall be
prohibited within the area measured 50 feet landward from the top-of-bank
of any watercourse.
B. Where permitted within any identified floodplain area, all manufactured
homes and any improvements thereto shall be:
(1)
Placed on a permanent foundation;
(2)
Elevated so that the lowest floor of the manufactured home is
at least 1 1/2 feet above base flood elevation;
(3)
Anchored to resist flotation, collapse, or lateral movement;
and
(4)
Have all ductwork and utilities, including HVAC/heat pump, elevated
to the regulatory flood elevation.
2. Installation of manufactured homes shall be done in accordance with
the manufacturers' installation instructions as provided by the
manufacturer. Where the applicant cannot provide the above information,
the requirements of Appendix E of the 2009 "International Residential
Building Code" or the "U.S. Department of Housing and Urban Development's
Permanent Foundations for Manufactured Housing," 1984 Edition, draft
or latest revision thereto, and 34 Pa. Code, Chapter 401–405,
shall apply.
3. Consideration shall be given to the installation requirements of
the 2009 IBC, and the 2009 IRC or the most recent revisions thereto
and 34 Pa. Code, as amended, where appropriate, and/or applicable
to units where the manufacturers' standards for anchoring cannot
be provided or were not established for the proposed unit(s) installation.
Within any identified floodplain area, recreational vehicles
shall be prohibited. If a variance is obtained in accordance with
the criteria in Part 8, then the following provisions apply:
1. Recreational vehicles in Zones A, A1-30, AH and AE must either:
A. Be on the site for fewer than 180 consecutive days;
B. Be fully licensed and ready for highway use; and
C. Be removed from floodplain if flood warning is issued.