An automatic fire sprinkler system shall be provided
throughout all buildings containing Group F-2 occupancies where the
Group F-2 fire area exceeds 7,500 square feet.
|
1.
|
The fire area exceeds 7,500 square feet.
|
2.
|
The building is three or more stories in height.
|
This section shall include all new and existing
automatic fire sprinkler systems, both required and nonrequired.
|
Safe exit discharge shall include snow/ice guards
on the roof of the structure when deemed necessary by the Building
Code Official.
|
Design snow loads shall be determined in accordance
with this section or shall comply with section 7 of ASCE listed in
Referenced Standards chapter. The design snow loads shall be determined
by Section 1608.2, but no less than 30 pounds per square foot.
|
Ground snow load: 30 PSF
|
Wind speed: 90 mph
|
Seismic design: Category B
|
Weathering: Severe
|
Frost line depth: 36 inches
|
Termites: Moderate to heavy
|
Decay: Slight to moderate
|
Winter design temperature: 14°
|
Ice shield underlayment: Yes
|
Flood hazards: Narberth Borough Floodplain Conservation
District Ordinance
|
Air freezing index: 689
|
Mean annual temperature: 53.1°
|
When unsuitable soil conditions are present or if
blasting is required in the excavation of footings and foundation,
two No. 4 diameter reinforcing bars are required to be installed in
the entire footing. If conditions warrant, a design professional shall
be consulted for footing/foundation design.
|
Insert "8" inches in place of "6" in the third sentence.
|
R405.1.2 Sump Pump Discharge Piping
Termination. Sump pump discharge piping shall terminate at least five
feet beyond the exterior foundation wall, but no closer than 10 feet
from a property line or the street right-of-way.
|
All on-lot sewage disposal systems shall comply
with the Pennsylvania Sewage Facilities Act 537 and shall be inspected
and approved by the Montgomery County Health Department. In existing
structures an approved inspection company shall verify that the on-lot
sewage disposal system properly operates in accordance with DEP regulations
prior to the issuance of any building permit. Noted deficiencies shall
be corrected within 30 days and approved by the Montgomery County
Health Department.
|
Water service pipe shall be installed a minimum
of 36 inches below finish grade.
|
Building sewers that connect to private sewage disposal
systems shall be a minimum depth below finished grade at the point
of septic tank connection which complies with the Narberth Borough
Subdivision and Land Development Ordinance and the requirements of
the Montgomery County Health Department. Building sewers shall be
a minimum depth below finished grade, as required by the sewer authority
having jurisdiction.
|
(Exception remains):
|
Hose bibbs subject to freezing, including the frost-proof
type, shall be equipped with an accessible stop-and-waste-type valve
inside the building, so that they can be controlled and/or drained
during cold periods, and with an atmospheric vacuum breaker.
|
Refuse, leaves and trimmings shall not be burned
outdoors on the premises in any manner whatsoever.
|
903.2.13 Group B. An automatic sprinkler system
shall be provided for Group B occupancies where one of the following
conditions exist: the fire area exceeds 7,500 square feet; or the
building is three or more stories in height.
|
This section shall include all new and existing
automatic fire sprinkler systems, both required and nonrequired.
|
This section shall include new and existing fire
alarm systems, both required and no-required, fire alarm and detection
systems.
|
Safe exit discharge shall include snow/ice guards
on the roof of the structure when deemed necessary by the Building
Code Official.
|
Before a fire permit is issued for blasting, the
permit applicant shall provide evidence of a current blasting license
from the Commonwealth of Pennsylvania and shall pay the required fee.
The application shall also provide a valid certificate of insurance
showing liability coverage for the blasting operation of not less
than $1,000,000.
|
The permit applicant shall submit the hold harmless
agreement executed with Narberth Borough, evidence of current workers
compensation insurance, DOT insurance, and general liability insurance
and umbrella insurance.
|
Insert "commercial properties," in front of "manufacturing
or industrial."
|
Water service pipe shall be a minimum of 36 inches
below finish grade.
|
Building sewers that connect to private sewage disposal
systems shall be a minimum depth below finished grade at the point
of septic tank connection which complies with the Narberth Borough
Subdivision and Land Development Ordinance and the requirements of
the Montgomery County Health Department. Building sewers shall be
a minimum depth below finished grade, as required by the sewer authority
having jurisdiction.
|
Wall hydrants installed on the exterior of the building
or other locations subject to freezing shall be automatic draining,
freezeless wall faucets.
|
Replace "where available" in the third line with
"when required by Borough ordinance."
|
Replace "International Private Sewage Disposal Code"
with the following: Pennsylvania Sewage Facilities Act 537 and shall
be inspected and approved by the Montgomery County Health Department.
In existing structures an approved inspection company shall verify
that the on-lot sewage disposal system properly operates in accordance
with DEP regulations prior to the issuance of any building permit.
Noted deficiencies shall be corrected within 30 days and approved
by the Montgomery County Health Department.
|