Table 5.1-1 Residential District Standards
[Amended 3-19-2007 by Ord. No. 1822; 1-29-2019 by Ord.
No. 1978]
| ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Standards
|
RS-4
|
RS-5
|
RS-7
|
RD-8
|
RD-19
|
RM-15
|
RM-15C
|
RM-24
|
RM-36
|
RMU
|
Minimum Lot Size
| ||||||||||
Lot Area (square feet)
|
10,000
|
4,500
|
6,250
|
6,250
|
4,000
|
4,000
|
5,000
|
5,000
|
4,000
|
5,500
|
Lot Area Per Dwelling Unit (square feet)
|
10,000
|
4,500
|
6,250
|
3,125
|
1,500
|
1,500
|
2,900
|
1,800
|
1,000
|
1,210
|
Lot Width (feet) [1]
|
75
|
33
|
50
|
50
|
33
|
33
|
40
|
50
|
33
|
44
|
Minimum Setback (feet)
| ||||||||||
Front [2]
|
25
|
25
|
20
|
20
|
20
|
20
|
20
|
20
|
15
|
15
|
Rear — abutting RS/RD districts
|
25
|
25
|
20
|
20
|
20
|
20
|
25
|
25
|
25
|
25
|
Rear — abutting RM/C/M districts
|
25
|
25
|
20
|
20
|
20
|
20
|
20
|
20
|
20
|
20
|
Side (interior) — abutting RS/RD districts
|
8
|
5
|
5
|
5
|
5
|
5
|
15
|
15 [3]
|
5 [3]
|
15 [3]
|
Side (interior) — abutting RM/C/M districts
|
8
|
5
|
5
|
5
|
5
|
5
|
5
|
5
|
5
|
5
|
Minimum Outdoor Area
| ||||||||||
Area (square feet per dwelling unit)
|
—
|
—
|
—
|
—
|
—
|
—
|
75
|
50
|
50
|
50
|
Minimum Dimension (feet)
|
—
|
—
|
—
|
—
|
—
|
—
|
7.5
|
5
|
5
|
5
|
Maximum Impervious Coverage
| ||||||||||
(percent of lot area) [4]
|
45
|
45
|
50
|
55
|
60
|
60
|
60
|
60
|
70
|
60
|
Maximum Height
| ||||||||||
(feet)
|
35
|
35
|
35
|
35
|
35
|
35
|
35
|
4 stories [5]
|
6 stories [5]
|
6 stories [5]
|
NOTES:
| |
---|---|
[1]
|
Lot width is measured at the front setback line.
|
[2]
|
Provided, however, that when 25% or more of all the
frontage on one side of a street between two intersecting streets
was, on April 22, 1954, built up with buildings, no building erected
or altered after that date shall project beyond the average of the
setback line so established, and provided, further, that no building
shall be required to set back more than 40 feet in any case as a result
of this provision.
|
[3]
|
Buildings over 35 feet in height shall have a side
yard setback of 15 feet.
|
[4]
|
The Planning Commission is authorized to modify impervious
cover limits for uses requiring special use permit approval.
|
[5]
|
Additional building height may be allowed if reviewed
and approved as a Planned Unit Development.
|
Table 5.2-1 Commercial And Manufacturing District Standards
[Amended 3-19-2007 by Ord. No. 1822; 6-6-2022 by Ord. No. 2049]
| |||||||||
---|---|---|---|---|---|---|---|---|---|
CMU
|
CNO
|
CN-1
|
CO
|
CN-2
|
CCBD
|
CBTR
|
M-1
|
M-2
| |
Minimum Site Area for Rezoning to the District
| |||||||||
(square feet)
|
—
|
—
|
—
|
5,000
|
1 Ac
|
—
|
2 Ac
|
1 Ac
|
1 Ac
|
Maximum Site Area
| |||||||||
(square feet)
|
—
|
—
|
15,000
|
7 Ac
|
—
|
—
|
—
|
—
| |
Minimum Lot Size
| |||||||||
Lot Area
(square feet)
|
2,900
|
6,250
|
2,900
|
5,000
|
5,000
|
—
|
—
|
5,000
|
5,000
|
Lot Area per Dwelling Unit
(square feet)
|
1,800
|
3,750
|
1,800
|
[1]
|
1,800
|
—
|
NA
|
NA
|
NA
|
Lot Width (feet)
|
—
|
50
|
—
|
[2]
|
—
|
—
|
—
|
—
|
—
|
Minimum Setbacks (feet)
| |||||||||
Front
|
—
|
15
|
—
|
50
|
—
|
25
| |||
Rear — abutting R district
|
15
|
25
|
15
|
15
|
15
|
—
|
50
|
25
|
50
|
Rear — abutting alley or C/M district
|
—
|
20
|
—
|
— [3]
|
—
|
—
|
50
|
—
|
25
|
Side (Interior) — abutting R district
|
15
|
15
|
15
|
15
|
15
|
—
|
25
|
25
|
50
|
Side (Interior) — abutting C/M district
|
6
|
—
|
— [3]
|
—
|
—
|
25
|
—
|
25
| |
Maximum Height
| |||||||||
(feet)
|
50
|
50
|
35
|
65
|
35
|
[4]
|
50 [5]
|
—
|
—
|
Maximum Impervious Cover
| |||||||||
(% of lot)
|
65
|
60
|
65
|
70
|
75
|
100
|
70
|
80
|
80
|
NOTES:
| |
---|---|
[1]
|
900 square feet of lot area per multifamily unit,
4000 square feet of lot area per single-family or duplex dwelling
unit.
|
[2]
|
No requirement unless the lot is used for residential
purposes, in which case the minimum lot width shall be 44 feet at
the building line.
|
[3]
|
No requirement unless the site is used for residential
purposes, in which case a setback of five feet shall be required.
|
[4]
|
See § 2.3G.4: CCBD Central Business District.
|
[5]
|
Mechanical equipment on the roof of the building may
not exceed 20 feet in height and must be screened. Mechanical equipment
is not counted toward the maximum building height of the building.
Maximum height of 30 feet for buildings located within 100 feet of
R districts or lots containing residential use.
|