Table 17.05-1: Commercial District Dimensional Standards
| ||||||
---|---|---|---|---|---|---|
C-T
|
C-1
|
C-2
|
C-3
|
C-C
|
C-OP
| |
Bulk
| ||||||
Minimum Lot Area
|
10,000 square feet
|
None
|
None
|
20,000 square feet
|
None
|
20,000 square feet
|
Minimum Lot Width
|
60 feet
|
None
|
None
|
80 feet
|
None
|
70 feet
|
Maximum Gross Floor Area of Nonresidential
|
5,000 square feet unless meeting the standards of Section 17.05.030B
|
None
|
None
|
None
|
None
|
None
|
Maximum Building Height
|
35 feet
|
45 feet
|
45 feet
|
Non-residential: 55 feet
Mixed-Use: 75 feet
|
None unless within 75 feet of a residential district, then 35
feet
|
45 feet
|
Setbacks
| ||||||
Minimum Front Setback
|
Build-to zone of 0 feet to 20 feet
|
Build-to zone of 0 feet to 15 feet unless meeting the standards of Section 17.05.030C
|
None
|
25 feet
|
None
|
20 feet
|
Front Setback Build-To Percentage
|
70%
|
70%
|
None
|
None
|
None
|
None
|
Minimum Interior Side Setback
|
None, unless abutting a residential district then 20 feet
|
None, unless abutting a residential district then 10 feet
|
None, unless abutting a residential district then 10 feet
|
10 feet, unless abutting a residential district then 20 feet
|
None, unless abutting a residential district, then 20 feet
|
15 feet
|
Minimum Corner Side Setback
|
Build-to zone of 0 feet to 15 feet
|
Build-to zone of 0 feet to 10 feet unless meeting the standards of Section 17.05.030C
|
10 feet
|
20 feet
|
None
|
Build-to zone of 0 feet to 20 feet
|
Corner Side Setback Build-To Percentage
|
60%
|
60%
|
None
|
None
|
None
|
60%
|
Minimum Rear Setback
|
15 feet, unless abutting a residential district then 25 feet
or 20% of lot depth, whichever is less
|
None, unless abutting a residential district then 15 feet or
20% of lot depth, whichever is less
|
None, unless abutting a residential district then 15 feet
|
10 feet, unless abutting a residential district then 25 feet
|
None, unless abutting a residential district, then 25 feet
|
25 feet
|
Table 17.05-2: Commercial District Design Standards
| ||||||
---|---|---|---|---|---|---|
C-T
|
C-1
|
C-2
|
C-3
|
C-C
|
C-OP
| |
Facade Design
| ||||||
Building facades that face a public right-of-way,
excluding alleys, must not contain blank wall areas that exceed 40
linear feet, measured parallel to the street
|
•
|
•
|
•
|
•
|
•
| |
Building facades in excess of 100 linear feet that
face a public right-of-way, excluding alleys, must include a repeating
pattern with no less than 2 of the following elements: color change,
texture change, building material change, or a wall articulation change
of no less than 2 feet in depth or projection, such as a reveal, pilaster,
or projecting rib. All elements must repeat at intervals of no more
than 40 linear feet
|
•
|
•
|
•
|
•
|
•
| |
Buildings with facades over 150 feet in length must
incorporate wall projections or recesses, or changes in wall plane
a minimum of 2 feet in depth a maximum of every 75 linear feet
|
•
| |||||
All buildings must have a public entrance from the
sidewalk along the primary building frontage. Public entrances must
be visually distinctive from the remaining portions of the facade
|
•
|
•
|
•
|
•
|
•
| |
Building materials and visual elements used on the
facade of the primary building frontage must continue on all building
facades that face a public right-of-way (excluding alleys) and/or
the lot line of a residential district
|
•
|
•
|
•
|
•
|
•
| |
Large expanses of highly reflective wall surface
material and mirror glass on exterior walls are prohibited
|
•
|
•
|
•
|
•
|
•
|
•
|
Fenestration Design
| ||||||
The ground floor of a facade facing a public right-of-way
(excluding alleys) must maintain a minimum transparency of 50%, measured
between 2 and 10 feet in height from grade.
|
•
|
•
| ||||
The ground floor of a facade facing a public right-of-way
(excluding alleys) must maintain a minimum transparency of 35%, measured
between 2 and 10 feet in height
|
•
|
•
| ||||
Upper floors of a facade facing a public right-of-way
(excluding alleys) must maintain a minimum transparency of 15% of
the wall area of the story
|
•
|
•
|
•
| |||
Roof Design
| ||||||
Rooflines over 100 linear feet in building length
must contain variation and incorporate a major focal point feature,
such as a dormer, gable, or projected wall feature. An element of
variegation on the roofline must occur at intervals of no more than
75 linear feet.
|
•
|
•
|
•
|
•
|
•
| |
Parapet walls must feature three-dimensional cornice
treatments or other shadow-creating details along their tops to provide
visual interest
|
•
|
•
|
•
|
•
|
•
| |
Any roof that is visible from a public right-of-way
must be shingle or colored standing seam metal roofing
|
•
|
•
|
•
|
•
|
•
| |
Green roof, blue roof, and white roof designs are
encouraged
|
•
|
•
|
•
|
•
|
•
|
•
|
Reflective roof surfaces that produce glare are
prohibited, except for solar panels or white roofs intended to radiate
absorbed or nonreflected solar energy and reduce heat transfer to
the building
|
•
|
•
|
•
|
•
|
•
|
•
|
Entrance Design
| ||||||
Public entrances and primary building elevations
must be oriented toward a public street. Main entrances to the buildings
must be well defined.
|
•
| |||||
Entries to office or guest facilities must address
the street, with direct access to office or guest facilities from
street frontages and parking areas
|
•
| |||||
Multi-Tenant Commercial Center and Office Park Site Design
| ||||||
Sites must be designed to ensure safe pedestrian
access to the commercial center from the public right-of-way and safe
pedestrian circulation within the development
|
•
|
•
|
•
|
•
| ||
A cohesive character must be established through
the use of coordinated hardscape (paving materials, lighting, street
furniture, etc.) and landscape treatments within the development
|
•
|
•
|
•
|
•
| ||
Commercial centers may provide definition along
the street frontage by locating part of the center or outlot buildings
within 0 feet to 25 feet of the front lot line. The center or any
outlot buildings may be placed within a required setback to comply
with this standard.
|
•
|
•
| ||||
In multi-building complexes, a distinct visual link
must be established between various buildings through the use of architectural
features or site design elements such as courtyards, plazas, landscape,
and walkways to unify the project
|
•
|
•
| ||||
Developments should provide a pedestrian link to
adjacent commercial uses to provide safe pedestrian access between
the site and commercial uses outside the development
|
•
|
Table 17.05-3: C-D District Dimensional Standards
| |
---|---|
C-D
| |
Bulk
| |
Minimum Lot Area
|
None
|
Minimum Lot Width
|
None
|
Maximum Building Height
|
None
|
Minimum Building Height
|
24 feet
|
Setbacks
| |
Front Setback
|
0 feet - 10 feet build-to zone
|
Required Build-to Percentage
|
80%
|
Interior Side Setback
|
None
|
Corner Side Setback
|
0 feet - 10 feet build-to zone
|
Rear Setback
|
None
|
Table 17.05-4: C-V District Dimensional Standards
| |
---|---|
C-V
| |
Bulk
| |
Minimum Lot Area
|
None
|
Minimum Lot Width
|
None
|
Maximum Building Height
|
45 feet
|
Setbacks
| |
Front Setback
|
0 feet - 10 feet build-to-zone, or average of adjacent structures
|
Required Build-to Percentage
|
80%
|
Interior Side Setback
|
None, unless abutting a residential district then 5 feet
|
Corner Side Setback
|
0 feet - 10 feet build-to zone
|
Rear Setback
|
None, unless abutting a residential district then 25 feet
|
Table 17.05-5: C-E District Dimensional Standards
| |
---|---|
Bulk
|
C-E
|
Minimum Lot Area
|
20,000 square feet
|
Minimum Lot Width
|
80 feet
|
Maximum Building Height
|
120 feet; 55 feet west and south of Elmore Avenue
|
Minimum Setbacks
| |
Front Setback
|
25 feet
|
Interior Side Setback
|
10 feet, unless abutting a residential district, then 25 feet
|
Corner Side Setback
|
20 feet
|
Rear Setback
|
10 feet, unless abutting a residential district, then 25 feet
|