Use
|
Minimum Required Parking and Loading Spaces Parking
|
---|---|
Churches and schools
|
1 for each 3.5 seats in auditorium or 1 for each 17 classroom
seats, whichever is greater.
|
Community buildings
|
1 for each 200 square feet of floor area.
|
Country clubs
|
1 for each 200 square feet of floor area occupied by all principal
structures.
|
Dwellings
|
2 for each family or dwelling unit.
|
Medical or dental office
|
6 for each doctor or dentist.
|
Golf courses
|
50 for each 9 holes.
|
Schools
|
1 per 15,000 square feet of floor area.
|
Number of Bedrooms
|
Minimum Floor Space
(square feet)
|
---|---|
1
|
800
|
2
|
1,000
|
3
|
1,200
|
Number of Bedrooms
|
Minimum Floor Space
(square feet)
|
---|---|
0 (efficiency apartments)
|
550
|
1
|
650
|
2
|
800
|
3 (affordable housing units only)
|
960
|
Number of Bedrooms
|
Minimum Floor Space for Garden Apts (square feet)
|
Minimum Floor Space for Senior Citizen Units
|
---|---|---|
0 (efficiency)
|
550
|
450
|
1
|
650
|
600
|
2
|
800
|
750
|
3 (affordable housing units only)
|
960
|
N/A
|
Zone
|
Minimum Habitable Dwelling Space
(square feet)
|
---|---|
R-130
|
1,400
|
R-40
|
1,400
|
R-20
|
1,200
|
R-10
|
1,100
|
B-1 Zone On-Street/Off-Street Parking and Off-Street Loading
| |
---|---|
Use
|
Minimum Parking
|
Funeral homes and mortuaries
|
10 per parlor
|
Retail stores, store groups, shops, consumer services, take
out food only, etc.
|
1 for each 300 square feet of floor area. Minimum 3 spaces
|
Eating/drinking establishments
|
1 for each 3 seats. Minimum 5 spaces
|
Medical or dental offices, and other professional offices
|
4 for each professional occupant
|
General business office
|
1 for each 300 square feet of floor area
|
Hotels and motels
|
1 per bedroom, plus 0.5 per employee on the highest shift
|
Dwelling units
|
As required by RSIS (except that the Board may consider approval
of a shared parking arrangement if the nature of the uses on the site
is such that there will not be overlapping demand for the shared parking
spaces). At all times there must be at least one dedicated parking
space per dwelling unit.
|
Minimum Loading
| |
---|---|
Offices
|
1 per 10,000 square feet of floor area
|
Retail, commercial, wholesale, manufacturing, storage and miscellaneous
uses
|
1 per 10,000 to 25,000 square feet of floor area; 2 for each
25,000 to 40,000 square feet of floor area; 3 for 40,000 to 60,000
square feet of floor area; 1 for each additional 50,000 square feet
of floor area or fraction thereof
|
Minimum Required Parking Use and Loading Spaces
| |
---|---|
Undertakers and funeral parlors
|
1 for each 5,000 square feet of floor area. 1 for each additional
5,000 square feet of floor area or major fraction thereof
|
Number of Bedrooms
|
Minimum Floor Space - Square Footage
|
---|---|
0
|
550 square feet (efficiency)
|
1
|
650 square feet
|
2
|
800 square feet
|
3 (affordable housing units only)
|
960 square feet
|
Number of Bedrooms
|
Minimum Floor Space - Square Footage
|
---|---|
0
|
550 square feet (efficiency)
|
1
|
650 square feet
|
2
|
800 square feet
|
3 (affordable housing units only)
|
960 square fee
|
BCD Zone On-Street/Off-Street Parking and Off-Street Loading
| |
---|---|
Use
|
Minimum Parking
|
Dwelling units
|
As required by RSIS (except that the Board may consider approval
of a shared parking arrangement if the nature of the uses on the site
is such that there will not be overlapping demand for the shared parking
spaces). At all times there must be at least one dedicated parking
space per dwelling unit.
|
Number of Bedrooms
|
Minimum Floor Space - Square Footage
|
---|---|
0
|
550 square feet (efficiency)
|
1
|
650 square feet
|
2
|
800 square feet
|
3 (affordable housing units only)
|
960 square feet
|
Use
|
Minimum Required Parking and Loading Spaces
|
---|---|
Manufacturing plants, research or testing laboratories and bottling
plants
|
1 for each 1,000 sf of floor area plus 1 for each 4 employees
|
Wholesale establishments and warehouses, retail and commercial
uses
|
1 for each 2 employees in a maximum shift. The total parking
area shall not be less than 25% for the building floor area
|
Loading
| |
---|---|
Retail, commercial, wholesale, manufacturing, storage and miscellaneous
uses
|
Same as in B-1 District
|
Noise - Table 1
| |
---|---|
Frequency Ranges Containing Standard Octave Bands
(cycles per second)
|
Octave Band Sound-Pressure Level
(decibels re 0.002 dyne/cm2)
|
20 — 300
|
60
|
300 - 2,400
|
40
|
Above 2,400
|
30
|
Noise - Table 2
| |
---|---|
Type or Location of Operation or Character of Noise
|
Correction in Decibels
|
Daytime operations only
|
5
|
Noise source operates less than:
| |
20% of any one-hour period
|
5
|
5% of any one-hour period
|
10
|
Noise of impulsive character (hammering, etc.)
|
˗5
|
Noise of periodic character (hum, screech, etc.)
|
˗5
|
Property is located in any M-1 Zone and is not within 500 feet
measured horizontally or vertically of any residential district.
|
10
|
NOTE: Apply one of these corrections only
|
Table of Frequency Amplitude Relations
| |
---|---|
Frequency of Ground Motion
(cycles per second)
|
Maximum Amplitude of Ground Motion
(inches)
|
Up to 10
|
.0305
|
10+ to 20
|
.0153
|
20+ to 30
|
.0102
|
30+ to 40
|
.0076
|
40+ to 50
|
.0061
|
50+ to 60
|
.0051
|
All operations activity must be in compliance with all noise
regulation provisions of N.J.S.A. 13:1G-1 et seq. and N.J.A.C. 7:29-1
et seq.
|
While the applicant shall not be required to submit detailed
geotechnical data, structural designs or shop drawings as part of
the site plan review, such information shall be provided to the Planning
Board Engineer as a condition of any approval. These data and drawings
shall be submitted under the signature of a New Jersey Licensed Professional
Engineer and the Planning Board Engineer shall review and approve
the data and drawings prior to any request for a construction permit
for said walls.
|
In the event a retaining wall is 30 inches or higher, the site
plan shall provide for placement of fencing along the portion of the
retaining wall, which is 30 inches or higher, and such fencing shall
be a minimum of four feet high. Fencing shall only be required along
the top tier of a multi-tiered wall where access is not available
to the lower tiers.7
|