Exciting enhancements are coming soon to eCode360! Learn more 🡪
City of Williston, ND
Williams County
By using eCode360 you agree to be legally bound by the Terms of Use. If you do not agree to the Terms of Use, please do not use eCode360.
Table of Contents
Table of Contents
[Ord. No. 595, A IV, § 1, 5-11-1982]
No unauthorized person shall uncover, make any connections with or opening into, use, alter, or disturb any public sewer or appurtenance thereof without first obtaining a written permit from the city commission.
[Ord. No. 595, A IV, § 2, 5-11-1982]
There shall be two classes of building sewer permits: (a) for residential and commercial service and (b) for service to establishments producing industrial wastes. In either case, the owner or his agent shall make application on a special form furnished by the city. The permit application shall be supplemented by any plans, specifications or other information considered pertinent in the judgment of the city commission. A permit and inspection fee of $12 for a residential or commercial building sewer permit and $12 for an industrial building sewer permit shall be paid to the city at the time the application is filed.
[Ord. No. 595, A IV, § 3, 5-11-1982]
All costs and expense incidental to the installation and connection of the building sewer shall be borne by the owner. The owner shall indemnify the city from any loss or damage that may directly or indirectly be occasioned by the installation of the building sewer.
[Ord. No. 595, A IV, § 4, 5-11-1982]
A separate and independent building sewer shall be provided for every building; except where one building stands at the rear of another on an interior lot and no private sewer is available or can be constructed to the rear building through an adjoining alley, court, yard, or driveway, the building sewer from the front building may be extended to the rear building and the whole considered as one building sewer, but the city does not and will not assume any obligation or responsibility for damage caused by or resulting from any such single connection aforementioned.
[Ord. No. 595, A IV, § 5, 5-11-1982]
Old building sewers may be used in connection with new buildings, only when they are found, on examination and test by the city commission, to meet all requirements of this chapter.
[Ord. No. 595, A IV, § 6, 5-11-1982]
The size, slope, alignment, materials of construction of all sanitary sewers including building sewers, and the methods to be used in excavating, placing of the pipe, jointing, testing and backfilling the trench, shall all conform to the requirements of the building and plumbing code or other applicable rules and regulations of the city. In the absence of suitable code provisions set forth in appropriate specifications of the A.S.T.M. and W.P.C.F. Manual of Practice No. 9 shall apply.
[Ord. No. 595, A IV, § 7, 5-11-1982]
Whenever possible, the building sewer shall be brought to the building at an elevation below the basement floor. In all buildings in which any building drain is too low to permit gravity flow to the public sewer, sanitary sewage carried by such building drain shall be lifted by an approved means and discharged to the building sewer.
[Ord. No. 595, A IV, § 8, 5-11-1982]
No person shall make connection of roof downspouts, foundation drains, areaway drains, or other sources of surface runoff or groundwater to a building sewer, or building drain which in turn is connected directly or indirectly to a public sanitary sewer unless such connection is approved by the Superintendent and the North Dakota State Department of Health.
[Ord. No. 595, A IV, § 9, 5-11-1982]
The connection of the building sewer into the public sewer shall conform to the requirements of the building and plumbing code or other applicable rules and regulations of the city or the procedures set forth in appropriate specifications of the A.S.T.M. and the W.P.C.F. Manual on Practice No. 9. All such connections shall be made gastight and watertight and verified by proper testing. Any deviation from the prescribed procedures and materials must be approved by the city commission before installation.
[Ord. No. 595, A IV, § 10, 5-11-1982]
The applicant for the building sewer permit shall notify the city commission when the building sewer is ready for inspection and connection to the public sewer. The connection and testing shall be made under the supervision of the city commission or its representative.
[Ord. No. 595, A IV, § 11, 5-11-1982]
All excavations for building sewer installation shall be adequately guarded with barricades and lights so as to protect the public from hazard. Streets, sidewalks, parkways and other public property disturbed in the course of the work shall be restored in a manner satisfactory to the city.
[Ord. No. 937, §§ 1 — 6, 8-23-2011]
(a) 
Discharge prohibited. Except as otherwise expressly authorized in this section, no ponds, water foundations, water from any roof, surface, groundwater sump pump, swimming pool, or other natural precipitation shall be discharged into the sanitary sewer system. Dwellings and other buildings and structures which require, because of infiltration of water into basements, crawl spaces, and the like, a sump pump discharge system shall have a permanently installed discharge line which shall not at any time discharge water into a sanitary sewer system. A permanent installation shall be one which provides for year round discharge capability to either the outside of the dwelling, building, or structure, or is connected to a storm sewer or discharge through the curb and gutter to the street. Within the home or business, the sump pump discharge pipe shall consist of a rigid discharge line, without valves or quick connections, that would alter the path of discharge. However, if the line is directly connected to a storm sewer line or catch basin a check valve and an air gap are required. Property owners are allowed to discharge directly into the sanitary sewer between October 1 and March 31 when reduced flows are present in the sanitary sewer collection system, if necessary.
(b) 
Inspections. Property owners shall allow an employee of the city or a designated representative of the city to inspect the buildings to confirm that there is no sump pump or other prohibited discharge into the sanitary sewer system. The city may periodically reinspect any building or premises to determine compliance with the requirements of this section, as to installation of all sump pumps.
(c) 
Removal of connections. Any property owner who previously made any connection or installation in violation of this section shall immediately remove such connection or correct such an installation. If not removed or corrected within 30 days after notice of the violation has been delivered personally or by certified mail to the owner, the city may impose a surcharge in the amount provided in Subsection (e) of this section. Such a surcharge may also be imposed upon any property owner, after a thirty-calendar day notice has been delivered, and if the owner refuses to allow their property to be inspected. The owner of a building or premises found to be not in conformance with this section during periodic reinspections may be subjected to a surcharge as provided in Subsection (e) of this section.
(d) 
Foundation drain tile.
(1) 
Future homes and businesses. Groundwater from foundation drain tile for future homes and businesses shall not discharge to the sanitary sewer system. The groundwater shall flow through the tile and drain to a sump basket and shall then be pumped and discharged to the exterior of the structure with the use of a sump pump.
(2) 
Existing homes and businesses. Some existing homes and businesses may have been constructed with groundwater from foundation drain tile discharging to the sanitary sewer. If the connection of the foundation drain tile to the sanitary sewer pipe is on the exterior of the home, the connection will be considered grandfathered and disconnection will not be required. If the connection of the foundation drain tile to the sanitary sewer pipe system is on the interior of the home or business, the connection is considered "not in compliance" and the owner is required to correct the improper connection. Any connection considered "not in compliance" shall abide by the subsections contained in this section.
(e) 
Surcharge. A surcharge of $100 per month is hereby imposed on every sewer bill to property owners for the following conditions:
(1) 
Not in compliance with this section.
(2) 
Refusal of property inspection.
(f) 