Any person violating or failing to comply with any provision
of this article shall be fined, upon conviction, in an amount not
more than $500.00. Separate offenses shall be deemed committed each
day during or on which a violation occurs or continues.
(Ordinance 2018-33 adopted 7/10/18)
The purpose and intent of this article is to provide minimum
standards, provisions and requirements and to provide for suitable
materials and methods of construction for newly constructed or reconstructed
residential or commercial driveways and parking lots hereafter constructed
or reconstructed within the corporate limits of the city or within
any subdivision of the city located in the extraterritorial jurisdiction
of the city.
(Ordinance 2018-33 adopted 7/10/18)
All new driveways and parking lots and all existing driveways
and parking lots being constructed or reconstructed within the corporate
limits of the city or within any subdivision located in the extraterritorial
jurisdiction of the city shall be constructed or reconstructed to
provide and meet the following minimum standards, materials and methods
of construction:
(1) Driveways and fire lanes.
(A) Residential.
Minimum ten feet wide, five-inch (5") concrete,
#3 rebar, 18-inch on center each way, and 3,600 psi.
(B) Commercial.
Nonfire lane parking shall be a minimum
of five inch (5") concrete, #3 rebar, 18-inch on center each way,
30-foot turning radius, 3,600 psi on six-inch lime stabilized subgrade.
Two inches (2") extra concrete may be used in lieu of lime or cement-stabilized
subgrade.
(C) Fire lanes.
Fire lanes shall be a minimum of six (6)
inches thick with a six inch (6") lime or cement stabilized subbase,
#3 rebar, 18-inch on center each way, 30-foot turning radius, and
have a minimum strength of 4,000 psi. Two inches (2") extra concrete
may be used in lieu of lime or cement-stabilized subgrade.
(2) Parking lots.
(A) Permanent parking lots (nonfire lane).
Minimum five-inch
concrete, #3 rebar, 18-inch on center each way, 3,600 psi on compacted
subgrade.
(B) Not-for-profit temporary parking lots.
Allowed only
for not-for-profit organizations, as defined by the Internal Revenue
Service (IRS), and limited to a maximum of three (3) years.
(ii)
Proof of not-for-profit status must be provided with the application.
(iii)
Applicants must own the property on which the temporary parking
will be placed.
(iv)
Applicants who are requesting a temporary parking lot for overflow
parking for an existing land use must have met or meet all the required
parking for the land use with permanent parking constructed to the
standards listed in subsection (2)(A), above.
(v) Applicants who are requesting a temporary parking lot for a new structure
must agree to provide the required parking for the land use with permanent
parking constructed to the standards listed in subsection (2)(A),
at the end of the time period allowed for the temporary unpaved parking
lot. Failure to install permanent parking for all required spaces
may result in the loss of the certificate of occupancy.
(vi)
Extensions of up to twelve (12) months may be allowed at the
discretion of the city manager.
(vii)
Material allowed: Gravel.
(viii)
Materials not allowed: Mulch, grass, and shredded recycled rubber
tires.
(3) Dumpster pads and related sites.
Minimum six inch (6")
concrete, #3 rebar, 18-inch on center each way, six-inch lime or cement
stabilized subgrade. Two inches (2") extra concrete can be used in
lieu of lime or cement stabilized sub-base.
(Ordinance 2018-33 adopted 7/10/18)