Good corner building with entrances on both streets.
|
Three-story commercial
(upper floor residential possible).
|
For Illustrative Purposes
| |||
1.
|
Commercial or residential use.
|
7.
|
Street trees and street lighting in continuous tree lawn or
tree grates
|
2.
|
Ground floor commercial use - required under main storefront
and optional under main BFS
|
8.
|
Optional awnings.
|
3.
|
Storefront, where required, with larger windows.
|
9.
|
Build-to line tight to sidewalk providing limited dooryard
|
4.
|
Minimum two story.
|
10.
|
Required minimum fenestration; must have windows and doors facing
street.
|
5.
|
Street wall where buildings do not abut
| ||
6.
|
Rear alley access preferable for parking and loading (service
access).
|
DIMENSIONS
|
DIMENSIONS
| |||||
A.
|
Build-to line
|
15 feet from curb or edge of paving
(Refer to Regulating Plan)
|
J.
|
Facade height maximum
(To top of wall plate)
|
4 stories/60 feet maximum (Canton)
3 stories/36 feet maximum (Collinsville)
| |
B.
|
Parking setback line
|
30 feet behind BTL
|
K.
|
Facade height minimum
(To top of wall plate)
|
2 stories/24 feet minimum
| |
C.
|
Rear setback
|
10 feet minimum - Collinsville
20 feet minimum - Canton
|
L.
|
Finished ground floor level
| ||
Business:
|
at grade minimum/18 inches maximum
| |||||
D.
|
Lot width
|
40 feet - Collinsville
20 feet - Canton Village
|
Residential:
|
at grade minimum/4 feet maximum
| ||
M.
|
Finished floor story clear height
| |||||
E.
|
Lot depth
|
75 feet - Collinsville
100 feet - Canton Village
|
Business:
|
12 feet minimum/18 feet maximum
| ||
Residential:
|
9 feet minimum/18 feet maximum
| |||||
F.
|
Side setback
|
N/A
|
N.
|
Upper story clear height
|
9 feet minimum/18 feet maximum
| |
G.
|
Private open space
|
10% of buildable area
|
O.
|
Optional attic height
|
8 feet minimum
| |
H.
|
Primary street facade
|
80% minimum
|
P.
|
Clear walkway width
|
5 feet minimum
| |
Interior buildings are allowed, provided all section and plan
elements are met (excluding build-to line). The maximum number of
stories of interior buildings in Canton Village may be increase by
one story (15 feet) as part of a Type II design application
|
Accessory buildings are allowed not greater than 25% of the
floor area of the principle building.
|
KEY
| |
see § 470-1201A(3)
| |
DIMENSIONS
|
DIMENSIONS
| |||||
A.
|
Parking setback line
|
15 feet from property line (Refer to Regulating Plan)
|
J.
|
Facade height maximum
|
4 stories/60 feet maximum
To top of wall plate
| |
B.
|
Build-to-zone
|
75 feet depth from property line
| ||||
C.
|
Rear setback
|
20 feet minimum
|
K.
|
Facade height minimum
|
2 stories/24 feet minimum
To top of wall plate
| |
D.
|
Lot width
|
70 feet minimum/200 feet maximum
| ||||
E.
|
Lot depth
|
175 feet minimum
|
L.
|
Finished ground floor level
| ||
F.
|
Side setback
|
N/A
|
Business:
|
at grade minimum/18 inches maximum*
| ||
G.
|
Private open space
|
10% of buildable area
|
M.
|
Finished floor story clear height
| ||
H.
|
Primary street facade
|
50% minimum
|
Business:
|
12 feet minimum/24 feet maximum
| ||
N.
|
Upper story clear height
|
9 feet minimum/18 feet maximum
| ||||
O.
|
Optional attic height
|
8 feet minimum
| ||||
P.
|
Clear walkway width
|
5 feet minimum
|
*
|
In the East Gateway, building exteriors must represent a two-story
construction from a minimum of three sides. This may be accomplished
through the provision of unoccupied/unfinished interior space, facade
elements, and other architectural treatments in provided the regards
to the upper story, provided the upper story requirements and corresponding
facade height is met for 75% of the structure on average. In a connected
row of multiple storefronts along a shared block face, the upper story
requirement must be met by a minimum of 75% of the connected facades.
|
**
|
8'0" min for Residential
|
Interior buildings are allowed provided all section and plan
elements are met (excluding build-to line). The maximum number of
stories of interior buildings may be increased by one story (15 feet)
as part of a Type II design application.
|
Accessory buildings are allowed not greater than 25% of the
floor area of the principle building.
|
Duplex (2 attached houses) type divided into four apartments
Attached single-family cottages
Architecturally detailed townhouses to articulate the row
|
Conventional Colonial-style rowhouses
Duplex (2-family) with appearance of single-family detached
|
For Illustrative Purposes
| |||
1.
|
Residential use
|
9.
|
Street trees and street lighting in continuous tree lawn or
tree grates
|
2.
|
Optional ground floor commercial use
|
10.
|
Build-to line behind sidewalk providing dooryard and front yard
|
3.
|
Narrow dimension facing primary street
|
11.
|
Small multifamily building (rental apartments or for sale condominiums)
|
4.
|
Raised finished floor level for ground floor residential use
|
12.
|
Individual single-family attached (fee simple townhouses)
|
5.
|
Optional stoop or porch
|
13.
|
Required minimum fenestration; must have windows and doors facing
street
|
6.
|
Minimum two story
| ||
7.
|
Street wall where buildings do not abut
| ||
8.
|
Rear alley access preferable for parking and loading (service
access)
| ||
DIMENSIONS
|
DIMENSIONS
| |||||
A.
|
Build-to line*
|
30 feet from curb or edge of paving (Refer to Regulating Plan)
|
J.
|
Facade height maximum
|
3 stories/48 feet maximum
To top of wall plate
| |
B.
|
Parking setback line
|
30 feet behind BTL except along accessways
| ||||
C.
|
Rear setback
|
25 feet minimum
|
K.
|
Facade height minimum
|
2 stories/24 feet minimum
To top of wall plate
| |
D.
|
Lot width
|
20 feet minimum
| ||||
E.
|
Lot depth
|
100 feet minimum
|
L.
|
Finished ground floor level
| ||
F.
|
Side setback
|
0 feet minimum/10 feet maximum (both sides)
5 feet maximum (one side)
|
Business:
|
at grade minimum/18 inches maximum
| ||
Residential:
|
at grade minimum/4 feet maximum
| |||||
G.
|
Private open space
|
20% of buildable area
|
M.
|
Finished floor story clear height
| ||
H.
|
Primary street facade
|
33% minimum
|
Business:
|
12 feet minimum/18 feet maximum
| ||
I.
|
Continuous primary street facade frontage (may include multiple
facades)
|
120 feet maximum
|
Residential:
|
9 feet minimum/18 feet maximum
| ||
N.
|
Upper story clear height
|
9 feet minimum/18 feet maximum
| ||||
O.
|
Optional attic height
|
8 feet minimum
| ||||
P.
|
Clear walkway width
|
5 feet minimum
|
Interior buildings are allowed provided all section and plan
elements are met (excluding build-to line). The maximum number of
stories of interior buildings may be increased by one additional story
(15 feet) as part of a Type II design plan application.
|
Accessory buildings are allowed not greater than 25% of the
floor area of the principle building.
|
Simple, yet well detailed, wood siding
Possible home occupation uses
|
Small lot (close together) single-family homes
One-story bungalow with local stone
Possible home occupation uses
|
For Illustrative Purposes
| |||
1.
|
Residential use
|
8.
|
On-street parking
|
2.
|
Optional business use (Harts Corner/Canton Village)
|
9.
|
Street trees and street lighting in continuous tree lawn
|
3.
|
Wider dimension facing street
|
10.
|
Build-to line set back providing front yard
|
4.
|
Optional stoop or porch
|
11.
|
Required fenestration; must have windows and doors facing street
|
5.
|
Minimum 1 1/2 story
| ||
6.
|
Private open space
| ||
7.
|
Preferable rear alley access preferable for off-street parking
| ||
DIMENSIONS
|
DIMENSIONS
| |||||
A.
|
Build-to-line
|
15 feet from property line
(Refer to Regulating Plan)
|
J.
|
Facade height maximum
|
2 1/2 stories/26 feet maximum
To top of wall plate
| |
B.
|
Parking setback line
|
30 feet behind BTL
|
K.
|
Facade height minimum
|
1 1/2 stories/18 feet minimum
To top of wall plate
| |
C.
|
Rear setback
|
25 feet minimum
| ||||
D.
|
Lot width*
|
40 feet minimum
|
L.
|
Finished ground floor level
|
2 feet minimum/4 feet maximum
| |
E.
|
Lot depth*
|
100 feet minimum
|
M.
|
Finished floor story clear height
| ||
F.
|
Side setback
|
5 feet minimum
|
Collinsville:
|
9 feet minimum 12 feet maximum
| ||
G.
|
Private open space
|
25% of buildable area
|
Canton Village:
|
9 feet minimum/14 feet maximum
| ||
H.
|
Optional porch width
|
33% minimum of facade
|
N.
|
Upper story clear height
|
9 feet minimum/12 feet maximum
| |
I.
|
Primary street facade
|
33% minimum
|
O.
|
Optional attic height
|
8 feet minimum
| |
P.
|
Optional front porch
|
6 feet minimum depth
| ||||
Q.
|
Accessory building
|
2 stories maximum/20 feet maximum
To top of wall plate
| ||||
Interior buildings are allowed provided all section and plan
elements are met (excluding build-to line). The maximum number of
stories of interior buildings in Canton Village may be increased by
one additional story (15 feet) as part of a Type II design plan application
|
Accessory buildings are allowed not greater than 25% of the
floor area of the principle building.
|
East Gateway Design Village District character example
Harts Corner Design Village District character example
Harts Corner Design Village District character example
|
East Gateway Design Village District character example
Harts Corner Design Village District character example
Harts Corner Design Village District character example
|
KEY
| |
see § 470-1201A(3)
| |
DIMENSIONS
|
DIMENSIONS
| |||||
A.
|
Parking Setback Line
|
15 feet from property line
(Refer to Regulating Plan
|
I.
|
Facade height maximum
|
2 1/2 stories/36 feet maximum
To top of wall plate
| |
B.
|
Build-to zone
|
75 feet depth
|
J.
|
Facade height minimum
|
1 1/2 stories/18 feet minimum
To top of wall plate
| |
C.
|
Rear setback
|
20 feet minimum
| ||||
D.
|
Lot width
|
70 feet minimum/200 feet maximum
|
K.
|
Finished ground floor level
|
at grade minimum/18 inches maximum
| |
E.
|
Lot depth
|
175 feet minimum
|
L.
|
Finished floor story clear height
|
9 feet minimum/18 feet maximum
| |
F.
|
Side setback
|
10 feet minimum
|
M.
|
Upper story clear height
|
9 feet minimum/14 feet maximum
| |
G.
|
Private open space
|
10% of buildable area
|
N.
|
Optional attic height
|
8 feet minimum
| |
H.
|
Primary street facade
|
50% minimum
|
O.
|
Optional front porch
|
6 feet minimum depth
| |
Interior buildings are allowed provided all section and plan
elements are met (excluding build-to line). The maximum number of
stories of interior buildings may be increased one story (15 feet)
as part of a Type II design application
|
Accessory buildings are allowed not greater than 25% of the
floor area of the principle building.
|